Literature DB >> 19265201

Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate.

Guang Li1, Naveen C Arora, Huchen Xie, Holly Ning, Wei Lu, Daniel Low, Deborah Citrin, Aradhana Kaushal, Leor Zach, Kevin Camphausen, Robert W Miller.   

Abstract

An external respiratory surrogate that not only highly correlates with but also quantitatively predicts internal tidal volume should be useful in guiding four-dimensional computed tomography (4DCT), as well as 4D radiation therapy (4DRT). A volumetric surrogate should have advantages over external fiducial point(s) for monitoring respiration-induced motion of the torso, which deforms in synchronization with a patient-specific breathing pattern. This study establishes a linear relationship between the external torso volume change (TVC) and lung air volume change (AVC) by validating a proposed volume conservation hypothesis (TVC = AVC) throughout the respiratory cycle using 4DCT and spirometry. Fourteen patients' torso 4DCT images and corresponding spirometric tidal volumes were acquired to examine this hypothesis. The 4DCT images were acquired using dual surrogates in ciné mode and amplitude-based binning in 12 respiratory stages, minimizing residual motion artifacts. Torso and lung volumes were calculated using threshold-based segmentation algorithms and volume changes were calculated relative to the full-exhalation stage. The TVC and AVC, as functions of respiratory stages, were compared, showing a high correlation (r = 0.992 +/- 0.005, p < 0.0001) as well as a linear relationship (slope = 1.027 +/- 0.061, R(2) = 0.980) without phase shift. The AVC was also compared to the spirometric tidal volumes, showing a similar linearity (slope = 1.030 +/- 0.092, R(2) = 0.947). In contrast, the thoracic and abdominal heights measured from 4DCT showed relatively low correlation (0.28 +/- 0.44 and 0.82 +/- 0.30, respectively) and location-dependent phase shifts. This novel approach establishes the foundation for developing an external volumetric respiratory surrogate.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19265201      PMCID: PMC7356673          DOI: 10.1088/0031-9155/54/7/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  37 in total

1.  Motion adaptive x-ray therapy: a feasibility study.

Authors:  P J Keall; V R Kini; S S Vedam; R Mohan
Journal:  Phys Med Biol       Date:  2001-01       Impact factor: 3.609

2.  Issues in respiratory motion compensation during external-beam radiotherapy.

Authors:  Cihat Ozhasoglu; Martin J Murphy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-04-01       Impact factor: 7.038

3.  Improving retrospective sorting of 4D computed tomography data.

Authors:  Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

4.  On the sources of drift in a turbine-based spirometer.

Authors:  Jonathan K Ha; Daniel B Perlow; Byong Yong Yi; Cedric X Yu
Journal:  Phys Med Biol       Date:  2008-07-24       Impact factor: 3.609

5.  Measurement of the separate volume changes of rib cage and abdomen during breathing.

Authors:  K Konno; J Mead
Journal:  J Appl Physiol       Date:  1967-03       Impact factor: 3.531

6.  Comparison of respiratory surrogates for gated lung radiotherapy without internal fiducials.

Authors:  S Korreman; H Mostafavi; Q-T Le; A Boyer
Journal:  Acta Oncol       Date:  2006       Impact factor: 4.089

7.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor.

Authors:  H Shirato; S Shimizu; K Kitamura; T Nishioka; K Kagei; S Hashimoto; H Aoyama; T Kunieda; N Shinohara; H Dosaka-Akita; K Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-09-01       Impact factor: 7.038

8.  Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking.

Authors:  Paul J Keall; Sarang Joshi; S Sastry Vedam; Jeffrey V Siebers; Vijaykumar R Kini; Radhe Mohan
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

9.  Four-dimensional computed tomography: image formation and clinical protocol.

Authors:  Eike Rietzel; Tinsu Pan; George T Y Chen
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

Review 10.  Advances in 4D medical imaging and 4D radiation therapy.

Authors:  G Li; D Citrin; K Camphausen; B Mueller; C Burman; B Mychalczak; R W Miller; Y Song
Journal:  Technol Cancer Res Treat       Date:  2008-02
View more
  12 in total

1.  Novel spirometry based on optical surface imaging.

Authors:  Guang Li; Hailiang Huang; Jie Wei; Diana G Li; Qing Chen; Carl P Gaebler; James Sullivan; Joan Zatcky; Andreas Rimner; James Mechalakos
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.

Authors:  Edward D Brandner; Indrin J Chetty; Tawfik G Giaddui; Ying Xiao; M Saiful Huq
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

3.  A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities.

Authors:  Amy Yuan; Jie Wei; Carl P Gaebler; Hailiang Huang; Devin Olek; Guang Li
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-09-03       Impact factor: 7.038

4.  Direct Comparison of Respiration-Correlated Four-Dimensional Magnetic Resonance Imaging Reconstructed Using Concurrent Internal Navigator and External Bellows.

Authors:  Guang Li; Jie Wei; Devin Olek; Mo Kadbi; Neelam Tyagi; Kristen Zakian; James Mechalakos; Joseph O Deasy; Margie Hunt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-11-09       Impact factor: 7.038

5.  Characterization of optical-surface-imaging-based spirometry for respiratory surrogating in radiotherapy.

Authors:  Guang Li; Jie Wei; Hailiang Huang; Qing Chen; Carl P Gaebler; Tiffany Lin; Amy Yuan; Andreas Rimner; James Mechalakos
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

6.  Automatic assessment of average diaphragm motion trajectory from 4DCT images through machine learning.

Authors:  Guang Li; Jie Wei; Hailiang Huang; Carl Philipp Gaebler; Amy Yuan; Joseph O Deasy
Journal:  Biomed Phys Eng Express       Date:  2015-12-29

7.  Evaluation of automatic contour propagation in T2-weighted 4DMRI for normal-tissue motion assessment using internal organ-at-risk volume (IRV).

Authors:  Jingjing Zhang; Svetlana Markova; Alejandro Garcia; Kirk Huang; Xingyu Nie; Wookjin Choi; Wei Lu; Abraham Wu; Andreas Rimner; Guang Li
Journal:  J Appl Clin Med Phys       Date:  2018-08-15       Impact factor: 2.102

8.  Enhancement of Long-Term External-Internal Correlation by Phase-Shift Detection and Correction Based on Concurrent External Bellows and Internal Navigator Signals.

Authors:  Andrew R Milewski; Devin Olek; Joseph O Deasy; Andreas Rimner; Guang Li
Journal:  Adv Radiat Oncol       Date:  2019-03-01

9.  Employing an Incentive Spirometer to Calibrate Tidal Volumes Estimated from a Smartphone Camera.

Authors:  Bersain A Reyes; Natasa Reljin; Youngsun Kong; Yunyoung Nam; Sangho Ha; Ki H Chon
Journal:  Sensors (Basel)       Date:  2016-03-18       Impact factor: 3.576

10.  Investigation of sliced body volume (SBV) as respiratory surrogate.

Authors:  Jing Cai; Zheng Chang; Jennifer O'Daniel; Sua Yoo; Hong Ge; Christopher Kelsey; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.