Literature DB >> 16982560

Comparison of respiratory surrogates for gated lung radiotherapy without internal fiducials.

S Korreman1, H Mostafavi, Q-T Le, A Boyer.   

Abstract

An investigation was carried out to compare the ability of two respiratory surrogates to mimic actual lung tumor motion during audio coaching. The investigation employed video clips acquired after patients had had fiducial markers implanted in lung tumors to be used for image-guided stereoscopic radiotherapy. The positions of the markers in the clips were measured within the video frames and used as the standard for tumor volume motion. An external marker was tracked optically during the fluoroscopic acquisitions. An image correlation technique was developed to compute a gating signal from the fluoroscopic images. The correlation gating trace was similar to the optical gating trace in the phase regions of the respiratory cycle used for gating. A cross correlation analysis and comparison of the external optical marker gating with internal fluoroscopic gating was performed. The fluoroscopic image correlation surrogate was found to be superior to the external optical surrogate in the AP-views in four out of six cases. In one of the remaining two cases, the two surrogates performed comparably, while in the last case, the external fiducial trace performed best. It was concluded that fluoroscopic gating based on correlation of native image features in the fluoroscopic images will be adequate for respiratory gating.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16982560     DOI: 10.1080/02841860600917161

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  5 in total

1.  Potential underestimation of the internal target volume (ITV) from free-breathing CBCT.

Authors:  Irina Vergalasova; Jacqueline Maurer; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

2.  Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate.

Authors:  Guang Li; Naveen C Arora; Huchen Xie; Holly Ning; Wei Lu; Daniel Low; Deborah Citrin; Aradhana Kaushal; Leor Zach; Kevin Camphausen; Robert W Miller
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

Review 3.  Image-guided radiotherapy and motion management in lung cancer.

Authors:  S S Korreman
Journal:  Br J Radiol       Date:  2015-05-08       Impact factor: 3.039

4.  External respiratory motion analysis and statistics for patients and volunteers.

Authors:  Sarah Quirk; Nathan Becker; W L Smith
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

5.  Investigation of tumor and vessel motion correlation in the liver.

Authors:  Sydney A Jupitz; Andrew J Shepard; Patrick M Hill; Bryan P Bednarz
Journal:  J Appl Clin Med Phys       Date:  2020-06-13       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.