Literature DB >> 22374285

320-detector row CT coronary angiography: effects of heart rate and heart rate variability on image quality, diagnostic accuracy and radiation exposure.

G Sun1, M Li, X-S Jiang, L Li, Z-H Peng, G-Y Li, L Xu.   

Abstract

OBJECTIVES: To evaluate the effects of heart rate and heart rate variability on image quality, patient dose and diagnostic accuracy of 320-detector row CT.
METHODS: 94 patients were prospectively enrolled. Heart rate was defined as the mean value of different intervals elapsing between two consecutive R waves in an electrocardiogram (R-R intervals) and the heart rate variability was calculated as the standard deviation from the average heart rate. The image quality was evaluated by four grades, according to motion artefacts ("step artefacts" and "blurring artefacts"). The diagnostic accuracy was analysed in 43 patients who were scheduled for invasive coronary angiography (ICA). The coeffects of heart rate and heart rate variability on image quality, radiation dose and diagnostic accuracy were evaluated by multivariate regression.
RESULTS: The mean image quality score was 1.2 ± 0.5 and the mean effective dose was 14.8 ± 9.8 mSv. The results showed that heart rate (74.0 ± 11.2 beats per minute) was the single factor influencing image quality (p<0.001) and radiation dose (p<0.001), while heart rate variability (3.7 ± 4.6) had no significant effect on them (p=0.16 and p=0.47, respectively). For 43 patients who underwent ICA, heart rate and heart rate variability showed no influence on the accuracy (p=0.17 and p=0.12, respectively). Overall sensitivity was 97.4% (37/38), specificity was 99.4% (351/353), positive predictive value was 94.9% (37/39) and negative predictive value was 99.7% (351/352).
CONCLUSION: 320-detector row CT, with improved longitudinal coverage of detector, resolves step artefact and high patient dose caused by irregular heart rate. However, it is still recommended to control heart rate to a lower level to eliminate blurring artefact and radiation dose.

Entities:  

Mesh:

Year:  2012        PMID: 22374285      PMCID: PMC3587067          DOI: 10.1259/bjr/92160185

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  23 in total

1.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

2.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

3.  Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

Authors:  David Matt; Hans Scheffel; Sebastian Leschka; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

4.  Ethical authorship and publishing.

Authors:  Andrew J S Coats
Journal:  Int J Cardiol       Date:  2008-11-28       Impact factor: 4.164

5.  Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose.

Authors:  Paul Stolzmann; Sebastian Leschka; Hans Scheffel; Tobias Krauss; Lotus Desbiolles; André Plass; Michele Genoni; Thomas G Flohr; Simon Wildermuth; Borut Marincek; Hatem Alkadhi
Journal:  Radiology       Date:  2008-10       Impact factor: 11.105

6.  Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality.

Authors:  Sebastian Leschka; Simon Wildermuth; Thomas Boehm; Lotus Desbiolles; Lars Husmann; André Plass; Pascal Koepfli; Tiziano Schepis; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Radiology       Date:  2006-09-11       Impact factor: 11.105

7.  Evaluation of CT coronary artery angiography with 320-row detector CT in a high-risk population.

Authors:  S Gang; L Min; L Li; L Guo-Ying; X Lin; J Qun; Z Hua
Journal:  Br J Radiol       Date:  2011-02-08       Impact factor: 3.039

8.  Effect of decrease in heart rate variability on the diagnostic accuracy of 64-MDCT coronary angiography.

Authors:  Sebastian Leschka; Hans Scheffel; Lars Husmann; Oliver Gämperli; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2008-06       Impact factor: 3.959

9.  Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy.

Authors:  Harald Brodoefel; Christof Burgstahler; Ilias Tsiflikas; Anja Reimann; Stephen Schroeder; Claus D Claussen; Martin Heuschmid; Andreas F Kopp
Journal:  Radiology       Date:  2008-03-27       Impact factor: 11.105

10.  Coronary artery motion and cardiac phases: dependency on heart rate -- implications for CT image reconstruction.

Authors:  Lars Husmann; Sebastian Leschka; Lotus Desbiolles; Tiziano Schepis; Oliver Gaemperli; Burkhardt Seifert; Philippe Cattin; Thomas Frauenfelder; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Radiology       Date:  2007-09-11       Impact factor: 11.105

View more
  13 in total

1.  Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine.

Authors:  Jean-François Paul; Aude Amato; Adela Rohnean
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-24       Impact factor: 2.357

2.  Feasibility Study of Computational Fluid Dynamics Simulation of Coronary Computed Tomography Angiography Based on Dual-Source Computed Tomography.

Authors:  Jing Lu; Jie Yu; Heshui Shi
Journal:  J Clin Med Res       Date:  2016-11-24

3.  Superior CT coronary angiography image quality at lower radiation exposure with second generation 320-detector row CT in patients with elevated heart rate: a comparison with first generation 320-detector row CT.

Authors:  Dennis T L Wong; Siang Y Soh; Brian S H Ko; James D Cameron; Marcus Crossett; Arthur Nasis; John Troupis; Ian T Meredith; Sujith K Seneviratne
Journal:  Cardiovasc Diagn Ther       Date:  2014-08

Review 4.  Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease.

Authors:  Linfeng Yang; Tao Zhou; Ruijie Zhang; Lin Xu; Zhaohui Peng; Juan Ding; Sen Wang; Min Li; Gang Sun
Journal:  Eur Radiol       Date:  2014-05-28       Impact factor: 5.315

Review 5.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

Review 6.  Selecting a CT scanner for cardiac imaging: the heart of the matter.

Authors:  Maria A Lewis; Ana Pascoal; Stephen F Keevil; Cornelius A Lewis
Journal:  Br J Radiol       Date:  2016-07-07       Impact factor: 3.039

7.  Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients.

Authors:  Marcus Y Chen; Sujata M Shanbhag; Andrew E Arai
Journal:  Radiology       Date:  2013-01-22       Impact factor: 11.105

8.  Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease.

Authors:  Akihiro Tada; Shuhei Sato; Yuichiro Kanie; Takashi Tanaka; Ryota Inai; Noriaki Akagi; Yusuke Morimitsu; Susumu Kanazawa
Journal:  Pediatr Cardiol       Date:  2015-11-12       Impact factor: 1.655

9.  The impact of image resolution on computation of fractional flow reserve: coronary computed tomography angiography versus 3-dimensional quantitative coronary angiography.

Authors:  Lili Liu; Wenjie Yang; Yasuomi Nagahara; Yingguang Li; Saeb R Lamooki; Takashi Muramatsu; Pieter Kitslaar; Masayoshi Sarai; Yukio Ozaki; Peter Barlis; Fuhua Yan; Johan H C Reiber; Shengxian Tu
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-27       Impact factor: 2.357

10.  Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

Authors:  Fabian Morsbach; Sonja Gordic; Lotus Desbiolles; Daniela Husarik; Thomas Frauenfelder; Bernhard Schmidt; Thomas Allmendinger; Simon Wildermuth; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2014-05-17       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.