Calculating T2 in images from a phased array receiver.

Peter A Hardy1, Anders H Andersen.   

Abstract

Images reconstructed from multielement, phased array coils and presented as the square root of the sum of the squares of the signals received by the individual elements have a distribution of signal and noise that distorts the relationship between the image intensity and the underlying signal. The distortion is accentuated for long echo times for which the signal-to-noise ratio (SNR) may be low. When measuring T(2) or T(2)* this signal distortion leads to biased estimates of these parameters. We demonstrate this effect and its dependence on the image SNR and the number of elements in a phased array coil. We evaluated the effects of four techniques for calculating T(2) from data acquired in phased array coils (log transform, least squares, lookup table correction, and maximum likelihood [ML] estimation). The ML estimation gave the most accurate T(2) in the presence of this bias.

Entities:  

Mesh:

Year:  2009        PMID: 19215046      PMCID: PMC2710582          DOI: 10.1002/mrm.21904

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Assessment of regional differences in myocardial blood flow using T2-weighted 3D BOLD imaging.

Authors:  K B Wright; F J Klocke; V S Deshpande; J Zheng; K R Harris; R Tang; J P Finn; D Li
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

3.  Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging.

Authors:  Jacco A de Zwart; Patrick J Ledden; Peter Kellman; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla.

Authors:  Jacco A de Zwart; Patrick J Ledden; Peter van Gelderen; Jerzy Bodurka; Renxin Chu; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

5.  Maximum likelihood estimation of signal amplitude and noise variance from MR data.

Authors:  J Sijbers; A J den Dekker
Journal:  Magn Reson Med       Date:  2004-03       Impact factor: 4.668

6.  Liver iron concentration evaluated by two magnetic methods: magnetic resonance imaging and magnetic susceptometry.

Authors:  Antonio Adilton O Carneiro; Juliana P Fernandes; Draulio B de Araujo; Jorge Elias; Ana L C Martinelli; Dimas T Covas; Marco A Zago; Ivan L Angulo; Timothy G St Pierre; Oswaldo Baffa
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

7.  Measurement of in vivo multi-component T2 relaxation times for brain tissue using multi-slice T2 prep at 1.5 and 3 T.

Authors:  Joonmi Oh; Eric T Han; Daniel Pelletier; Sarah J Nelson
Journal:  Magn Reson Imaging       Date:  2005-12-19       Impact factor: 2.546

8.  An unbiased signal-to-noise ratio measure for magnetic resonance images.

Authors:  G McGibney; M R Smith
Journal:  Med Phys       Date:  1993 Jul-Aug       Impact factor: 4.071

9.  Iron accumulation in the striatum predicts aging-related decline in motor function in rhesus monkeys.

Authors:  Wayne A Cass; Richard Grondin; Anders H Andersen; Zhiming Zhang; Peter A Hardy; Lindsay K Hussey-Andersen; William S Rayens; Greg A Gerhardt; Don M Gash
Journal:  Neurobiol Aging       Date:  2006-01-26       Impact factor: 4.673

10.  R2 and R2* mapping for sensing cell-bound superparamagnetic nanoparticles: in vitro and murine in vivo testing.

Authors:  Rebecca Kuhlpeter; Hannes Dahnke; Lars Matuszewski; Thorsten Persigehl; Angelika von Wallbrunn; Thomas Allkemper; Walter L Heindel; Tobias Schaeffter; Christoph Bremer
Journal:  Radiology       Date:  2007-09-11       Impact factor: 11.105

View more
  5 in total

Review 1.  Errors in quantitative T1rho imaging and the correction methods.

Authors:  Weitian Chen
Journal:  Quant Imaging Med Surg       Date:  2015-08

2.  A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.

Authors:  Yoichi Watanabe; Hitoshi Kubo
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

3.  Bayesian analysis of transverse signal decay with application to human brain.

Authors:  Mustapha Bouhrara; David A Reiter; Richard G Spencer
Journal:  Magn Reson Med       Date:  2014-09-19       Impact factor: 4.668

4.  Algorithm for fast monoexponential fitting based on Auto-Regression on Linear Operations (ARLO) of data.

Authors:  Mengchao Pei; Thanh D Nguyen; Nanda D Thimmappa; Carlo Salustri; Fang Dong; Mitch A Cooper; Jianqi Li; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2014-03-24       Impact factor: 4.668

5.  Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping.

Authors:  Alois M Sprinkart; Julian A Luetkens; Frank Träber; Jonas Doerner; Jürgen Gieseke; Bernhard Schnackenburg; Georg Schmitz; Daniel Thomas; Rami Homsi; Wolfgang Block; Hans Schild; Claas P Naehle
Journal:  J Cardiovasc Magn Reson       Date:  2015-02-12       Impact factor: 5.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.