Literature DB >> 16410176

Measurement of in vivo multi-component T2 relaxation times for brain tissue using multi-slice T2 prep at 1.5 and 3 T.

Joonmi Oh1, Eric T Han, Daniel Pelletier, Sarah J Nelson.   

Abstract

The objective of this study was to implement a clinically relevant multi-slice multi-echo imaging sequence in order to quantify multi-component T2 relaxation times for normal volunteers at both 1.5 and 3 T. Multi-echo data were fitted using a nonnegative least square algorithm. Twelve echo data with nonlinear echo sampling were acquired using a receive-only eight-channel phased array coil and volume head coil for phantoms and normal volunteers, and compared to 32-echo data with linear echo sampling. It was observed that the performance of the 180 degrees refocusing trains was more spatially uniform for the receive-only eight-channel phased array coil than for the head coil, particularly at 3 T. The phantom study showed that the estimated T2 relaxation times were accurate and reproducible for both single- and multi-slice acquisition from a commercial phantom with known T2 relaxation times. Short T2 components (T2 <50 ms) were mainly observed within the white matter for normal volunteers, and the fraction of short T2 water components (i.e., myelin water) was 7-12% of total water. It was observed that the calculated myelin water fraction map from the nonlinearly sampled 12-echo data was comparable with that from the linearly sampled 32-echo data. Quantification of T2 relaxation times from multi-slice images was accomplished with a clinically acceptable scan times (16 min) for normal volunteers by using a nonselective T2 prep imaging sequence. The use of the eight-channel head coil involved more accurate quantification of T2 relaxation times particularly when the number of echoes was limited.

Entities:  

Mesh:

Year:  2005        PMID: 16410176     DOI: 10.1016/j.mri.2005.10.016

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  40 in total

1.  Nonexponential T₂ decay in white matter.

Authors:  Peter van Gelderen; Jacco A de Zwart; Jongho Lee; Pascal Sati; Daniel S Reich; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

2.  Limitations of rapid myelin water quantification using 3D bSSFP.

Authors:  C Lenz; M Klarhöfer; K Scheffler
Journal:  MAGMA       Date:  2010-04-28       Impact factor: 2.310

3.  Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent repetition time (TR) dependence for fast T2 measurement.

Authors:  Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun
Journal:  NMR Biomed       Date:  2011-07-14       Impact factor: 4.044

4.  Quantitative T2 measurement of a single voxel with arbitrary shape using pinwheel excitation and CPMG acquisition.

Authors:  Qin Qin; John C Gore; Robin A de Graaf; Mark D Does
Journal:  MAGMA       Date:  2007-11-13       Impact factor: 2.310

Review 5.  Magnetic resonance imaging of myelin.

Authors:  Cornelia Laule; Irene M Vavasour; Shannon H Kolind; David K B Li; Tony L Traboulsee; G R Wayne Moore; Alex L MacKay
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

6.  Spatial analysis of magnetic resonance T1rho and T2 relaxation times improves classification between subjects with and without osteoarthritis.

Authors:  Julio Carballido-Gamio; Robert Stahl; Gabrielle Blumenkrantz; Adan Romero; Sharmila Majumdar; Thomas M Link
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

Review 7.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

Review 8.  MRI in multiple sclerosis: current status and future prospects.

Authors:  Rohit Bakshi; Alan J Thompson; Maria A Rocca; Daniel Pelletier; Vincent Dousset; Frederik Barkhof; Matilde Inglese; Charles R G Guttmann; Mark A Horsfield; Massimo Filippi
Journal:  Lancet Neurol       Date:  2008-07       Impact factor: 44.182

9.  Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

Authors:  Hadrien Dyvorne; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-12-01       Impact factor: 4.668

10.  Calculating T2 in images from a phased array receiver.

Authors:  Peter A Hardy; Anders H Andersen
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.