Literature DB >> 19196520

Selection of the optimum electrospray voltage for gradient elution LC-MS measurements.

Ioan Marginean1, Ryan T Kelly, Ronald J Moore, David C Prior, Brian L LaMarche, Keqi Tang, Richard D Smith.   

Abstract

Changes in liquid composition during gradient elution liquid chromatography (LC) coupled to mass spectrometry (MS) analyses affect the electrospray operation. To establish methodologies for judicious selection of the electrospray voltage, we monitored in real time the effect of the LC gradient on the spray current. The optimum range of the electrospray voltage decreased as the concentration of organic solvent in the eluent increased during reversed-phase LC analyses. These results and related observations provided the means to rationally select the voltage to ensure effective electrospray operation throughout gradient-elution LC separations. For analyses in which the electrospray was operated at constant voltage, a small run-to-run variation in the spray current was observed, indicating a changing electric field resulting from fouling or degradation of the emitter. Algorithms using feedback from spray current measurements that can maintain the electrospray voltage within the optimum operating range throughout gradient elution LC-MS were evaluated. The electrospray operation with voltage regulation and at a constant, judiciously selected voltage during gradient elution LC-MS measurements produced data with similar reproducibility.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19196520      PMCID: PMC2692488          DOI: 10.1016/j.jasms.2008.12.004

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  20 in total

1.  Electrical equivalence of electrospray ionization with conducting and nonconducting needles.

Authors:  G S Jackson; C G Enke
Journal:  Anal Chem       Date:  1999-09-01       Impact factor: 6.986

2.  High-throughput proteomics using high-efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry.

Authors:  Y Shen; N Tolić; R Zhao; L Pasa-Tolić; L Li; S J Berger; R Harkewicz; G A Anderson; M E Belov; R D Smith
Journal:  Anal Chem       Date:  2001-07-01       Impact factor: 6.986

3.  Oxidation artifacts in the electrospray mass spectrometry of Abeta Peptide.

Authors:  Maolian Chen; Kelsey D Cook
Journal:  Anal Chem       Date:  2007-01-24       Impact factor: 6.986

4.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Quanzhou Luo; Ronald J Moore; Daniel J Orton; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

5.  Electrospray characteristic curves: in pursuit of improved performance in the nanoflow regime.

Authors:  Ioan Marginean; Ryan T Kelly; Jason S Page; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2007-09-27       Impact factor: 6.986

6.  Label-free quantitative proteomics using large peptide data sets generated by nanoflow liquid chromatography and mass spectrometry.

Authors:  Masaya Ono; Miki Shitashige; Kazufumi Honda; Tomohiro Isobe; Hideya Kuwabara; Hirotaka Matsuzuki; Setsuo Hirohashi; Tesshi Yamada
Journal:  Mol Cell Proteomics       Date:  2006-03-21       Impact factor: 5.911

7.  Electrospray interface for liquid chromatographs and mass spectrometers.

Authors:  C M Whitehouse; R N Dreyer; M Yamashita; J B Fenn
Journal:  Anal Chem       Date:  1985-03       Impact factor: 6.986

8.  Response normalized liquid chromatography nanospray ionization mass spectrometry.

Authors:  Ragu Ramanathan; Ruyun Zhong; Neil Blumenkrantz; Swapan K Chowdhury; Kevin B Alton
Journal:  J Am Soc Mass Spectrom       Date:  2007-07-29       Impact factor: 3.109

9.  Analytical characterization of the electrospray ion source in the nanoflow regime.

Authors:  Ioan Marginean; Ryan T Kelly; David C Prior; Brian L LaMarche; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2008-07-29       Impact factor: 6.986

10.  Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data.

Authors:  Navdeep Jaitly; Anoop Mayampurath; Kyle Littlefield; Joshua N Adkins; Gordon A Anderson; Richard D Smith
Journal:  BMC Bioinformatics       Date:  2009-03-17       Impact factor: 3.169

View more
  4 in total

1.  Performance comparisons of nano-LC systems, electrospray sources and LC-MS-MS platforms.

Authors:  Qian Liu; Jennifer S Cobb; Joshua L Johnson; Qi Wang; Jeffrey N Agar
Journal:  J Chromatogr Sci       Date:  2013-01-17       Impact factor: 1.618

2.  Macaque proteome response to highly pathogenic avian influenza and 1918 reassortant influenza virus infections.

Authors:  Joseph N Brown; Robert E Palermo; Carole R Baskin; Marina Gritsenko; Patrick J Sabourin; James P Long; Carol L Sabourin; Helle Bielefeldt-Ohmann; Adolfo García-Sastre; Randy Albrecht; Terrence M Tumpey; Jon M Jacobs; Richard D Smith; Michael G Katze
Journal:  J Virol       Date:  2010-09-15       Impact factor: 5.103

3.  Morphine produces immunosuppressive effects in nonhuman primates at the proteomic and cellular levels.

Authors:  Joseph N Brown; Gabriel M Ortiz; Thomas E Angel; Jon M Jacobs; Marina Gritsenko; Eric Y Chan; David E Purdy; Robert D Murnane; Kay Larsen; Robert E Palermo; Anil K Shukla; Theresa R Clauss; Michael G Katze; Joseph M McCune; Richard D Smith
Journal:  Mol Cell Proteomics       Date:  2012-05-11       Impact factor: 5.911

4.  Proteomic analysis of saliva in HIV-positive heroin addicts reveals proteins correlated with cognition.

Authors:  Stephen S Dominy; Joseph N Brown; Mark I Ryder; Marina Gritsenko; Jon M Jacobs; Richard D Smith
Journal:  PLoS One       Date:  2014-04-09       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.