Literature DB >> 11467548

High-throughput proteomics using high-efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry.

Y Shen1, N Tolić, R Zhao, L Pasa-Tolić, L Li, S J Berger, R Harkewicz, G A Anderson, M E Belov, R D Smith.   

Abstract

We report on the design and application of a high-efficiency multiple-capillary liquid chromatography (LC) system for high-throughput proteome analysis. The multiple-capillary LC system using commercial LC pumps was operated at a pressure of 10,000 psi to deliver mobile phases through a novel passive feedback valve arrangement that permitted mobile-phase flow path switching and efficient sample introduction. The multiple-capillary LC system uses several serially connected dual-capillary column devices. The dual-capillary column approach eliminates the time delays for column regeneration (or equilibration) since one capillary column was used for a separation while the other was being washed. Several serially connected dual-capillary columns and electrospray ionization (ESI) sources were operated independently and can be used either for "backup" operation or for parallel operation with other mass spectrometers. This high-efficiency multiple-capillary LC system utilizes switching valves for all operations, enabling automated operation. The separation efficiency of the dual-capillary column arrangement, optimal capillary dimensions (column length and packed particle size), capillary regeneration conditions, and mobile-phase compositions and their compatibility with electrospray ionization were investigated. A high magnetic field (11.4 T) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer was coupled on-line with this high-efficiency multiple-capillary LC system using an ESI interface. The capillary LC provided a peak capacity of approximately 650, and the 2-D capillary LC-FTICR analysis provided a combined resolving power of > 6 x 10(7) components. For yeast cytosolic tryptic digests > 100,000 polypeptides were detected, and approximately 1,000 proteins could be characterized from a single capillary LC-FTICR analysis using the high mass measurement accuracy (approximately 1 ppm) of FTICR, and likely more if LC retention time information were also exploited for peptide identification.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11467548     DOI: 10.1021/ac001393n

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  43 in total

1.  Frequency shifts due to the interference of resolved peaks in magnitude-mode Fourier-transform ion cyclotron resonance mass spectra.

Authors:  Aleksey V Tolmachev; Christophe D Masselon; Gordon A Anderson; Harold R Udseth; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2002-04       Impact factor: 3.109

2.  Direct mass spectrometric analysis of intact proteins of the yeast large ribosomal subunit using capillary LC/FTICR.

Authors:  Sang-Won Lee; Scott J Berger; Suzana Martinović; Ljiljana Pasa-Tolić; Gordon A Anderson; Yufeng Shen; Rui Zhao; Richard D Smith
Journal:  Proc Natl Acad Sci U S A       Date:  2002-04-30       Impact factor: 11.205

3.  ESI-FTICR mass spectrometry employing data-dependent external ion selection and accumulation.

Authors:  Richard Harkewicz; Mikhail E Belov; Gordon A Anderson; Ljiljana Pasa-Tolić; Christophe D Masselon; David C Prior; Harold R Udseth; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2002-02       Impact factor: 3.109

4.  Controlled ion fragmentation in a 2-D quadrupole ion trap for external ion accumulation in ESI FTICR mass spectrometry.

Authors:  M E Belov; M V Gorshkov; H R Udseth; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2001-12       Impact factor: 3.109

5.  On-line integration of PCR and cycle sequencing in capillaries: from human genomic DNA directly to called bases.

Authors:  Masahiko Hashimoto; Yan He; Edward S Yeung
Journal:  Nucleic Acids Res       Date:  2003-04-15       Impact factor: 16.971

6.  An automated high performance capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometer for high-throughput proteomics.

Authors:  Mikhail E Belov; Gordon A Anderson; Mark A Wingerd; Harold R Udseth; Keqi Tang; David C Prior; Kenneth R Swanson; Michael A Buschbach; Eric F Strittmatter; Ronald J Moore; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2004-02       Impact factor: 3.109

7.  Proteome analyses using accurate mass and elution time peptide tags with capillary LC time-of-flight mass spectrometry.

Authors:  Eric F Strittmatter; P Lee Ferguson; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2003-09       Impact factor: 3.109

8.  Global analysis of the Deinococcus radiodurans proteome by using accurate mass tags.

Authors:  Mary S Lipton; Ljiljana Pasa-Tolic'; Gordon A Anderson; David J Anderson; Deanna L Auberry; John R Battista; Michael J Daly; Jim Fredrickson; Kim K Hixson; Heather Kostandarithes; Christophe Masselon; Lye Meng Markillie; Ronald J Moore; Margaret F Romine; Yufeng Shen; Eric Stritmatter; Nikola Tolic'; Harold R Udseth; Amudhan Venkateswaran; Kwong-Kwok Wong; Rui Zhao; Richard D Smith
Journal:  Proc Natl Acad Sci U S A       Date:  2002-08-12       Impact factor: 11.205

9.  Improved peptide elution time prediction for reversed-phase liquid chromatography-MS by incorporating peptide sequence information.

Authors:  Konstantinos Petritis; Lars J Kangas; Bo Yan; Matthew E Monroe; Eric F Strittmatter; Wei-Jun Qian; Joshua N Adkins; Ronald J Moore; Ying Xu; Mary S Lipton; David G Camp; Richard D Smith
Journal:  Anal Chem       Date:  2006-07-15       Impact factor: 6.986

10.  An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies.

Authors:  Erin Shammel Baker; Eric A Livesay; Daniel J Orton; Ronald J Moore; William F Danielson; David C Prior; Yehia M Ibrahim; Brian L LaMarche; Anoop M Mayampurath; Athena A Schepmoes; Derek F Hopkins; Keqi Tang; Richard D Smith; Mikhail E Belov
Journal:  J Proteome Res       Date:  2010-02-05       Impact factor: 4.466

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.