Literature DB >> 23202544

Measurements of entrance-surface vs. conventional single-ended readout of a monolithic scintillator.

William C J Hunter1, Wendy McDougald, Jerome J Griesmer, Lingxiong Shao, Robert Zahn, Tom K Lewellen, Robert S Miyaoka.   

Abstract

Availability of compact high-gain, low-noise Silicon Photomultipliers (SiPM) prompts us to examine readout sensors on the entrance surface (SES) as compared to the conventional single-ended readout with sensors on the opposing surface. We measured detector response statistics versus 3D position for these configurations using an 8×8 SiPM array on a 15-mm-thick by 32-mm-wide LYSO block. We calibrate an independently distributed multivariate-normal likelihood model and use it to generate maximum-likelihood estimates of 3D interaction position. Spatial resolution improved 14% and timing resolution improved 10% for the SES device. Bias was unaffected. Photodetection efficiency of our prototype SiPM may have limited further improvement in positioning and timing performance. In future work, we will look to utilize SiPM arrays with enhanced photodetection efficiency.

Entities:  

Year:  2011        PMID: 23202544      PMCID: PMC3509750          DOI: 10.1109/nssmic.2011.6153688

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  5 in total

1.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.

Authors:  Yuan-Chuan Tai; Arion F Chatziioannou; Yongfeng Yang; Robert W Silverman; Ken Meadors; Stefan Siegel; Danny F Newport; Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2003-06-07       Impact factor: 3.609

2.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

3.  A high resolution, monolithic crystal, PET/MRI detector with DOI positioning capability.

Authors:  Xiaoli Li; Cate Lockhart; Tom K Lewellen; Robert S Miyaoka
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

4.  Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2010       Impact factor: 1.679

5.  Development of a single detector ring micro crystal element scanner: QuickPET II.

Authors:  Robert S Miyaoka; Marie L Janes; Kisung Lee; Byungki Park; Paul E Kinahan; Tom K Lewellen
Journal:  Mol Imaging       Date:  2005 Apr-Jun       Impact factor: 4.488

  5 in total
  1 in total

1.  Performance Evaluation of Small Animal PET Scanners With Different System Designs.

Authors:  Xiaoli Li; Adam M Alessio; Thompson H Burnett; Thomas K Lewellen; Roberts Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2013-06       Impact factor: 1.679

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.