Literature DB >> 19149461

Quantitative assessment of the magnitude, impact and spatial extent of ultrasonic clutter.

Muyinatu A Lediju1, Michael J Pihl, Jeremy J Dahl, Gregg E Trahey.   

Abstract

Clutter is anoise artifact in ultrasound images that appears as diffuse echoes overlying signals of interest. It is most easily observed in anechoic or hypoechoic regions, such as in cysts, blood vessels, amniotic fluid, and urine-filled bladders. Clutter often obscures targets of interest and complicates anatomical measurements. An analytical expression that characterizes the extent to which clutter degrades lesion contrast was derived and compared to the measured contrast loss due to clutter in a bladder phantom. Simulation and phantom studies were performed to determine ideal and achievable signal-to-clutter ratios. In vivo clutter magnitudes were quantified in simultaneously-acquired fundamental and harmonic bladder images from five volunteers. Clutter magnitudes ranged from -30 dB to 0 dB, relative to the mean signal of the bladder wall. For this range of clutter magnitudes, the analytical expression predicts a contrast loss of 0-45 dB for lesions with clutter-free contrasts of 6-48 dB. A pixel-wise comparison of simultaneously-acquired fundamental and harmonic bladder images from each volunteer revealed an overall signal reduction in harmonic images, with average reductions ranging from 11-18 dB in the bladder interior and 9-11 dB in the tissue surrounding the bladder. Harmonic imaging did not reduce clutter in all volunteers.

Entities:  

Mesh:

Year:  2008        PMID: 19149461      PMCID: PMC3306837          DOI: 10.1177/016173460803000302

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  19 in total

1.  Real-time spatial compound imaging in breast ultrasound.

Authors:  Sabine Huber; Monika Wagner; Michael Medl; Heinrich Czembirek
Journal:  Ultrasound Med Biol       Date:  2002-02       Impact factor: 2.998

Review 2.  Nonlinear acoustics in diagnostic ultrasound.

Authors:  Francis A Duck
Journal:  Ultrasound Med Biol       Date:  2002-01       Impact factor: 2.998

3.  Stationary clutter rejection in echocardiography.

Authors:  Gil Zwirn; Solange Akselrod
Journal:  Ultrasound Med Biol       Date:  2006-01       Impact factor: 2.998

4.  Improvement of tissue harmonic imaging using the pulse-inversion technique.

Authors:  Qingyu Ma; Yong Ma; Xiufen Gong; Dong Zhang
Journal:  Ultrasound Med Biol       Date:  2005-07       Impact factor: 2.998

5.  Time-domain optimized near-field estimator for ultrasound imaging: initial development and results.

Authors:  F Viola; M A Ellis; W F Walker
Journal:  IEEE Trans Med Imaging       Date:  2008-01       Impact factor: 10.048

6.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

7.  Tissue harmonic imaging: why does it work?

Authors:  J D Thomas; D N Rubin
Journal:  J Am Soc Echocardiogr       Date:  1998-08       Impact factor: 5.251

8.  Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image quality.

Authors:  K T Spencer; J Bednarz; P G Rafter; C Korcarz; R M Lang
Journal:  Am J Cardiol       Date:  1998-09-15       Impact factor: 2.778

9.  The effect of abdominal wall morphology on ultrasonic pulse distortion. Part I. Measurements.

Authors:  L M Hinkelman; T D Mast; L A Metlay; R C Waag
Journal:  J Acoust Soc Am       Date:  1998-12       Impact factor: 1.840

10.  The development of harmonic distortion in pulsed finite-amplitude ultrasound passing through liver.

Authors:  H C Starritt; F A Duck; A J Hawkins; V F Humphrey
Journal:  Phys Med Biol       Date:  1986-12       Impact factor: 3.609

View more
  46 in total

1.  Robust Short-Lag Spatial Coherence Imaging of Breast Ultrasound Data: Initial Clinical Results.

Authors:  Alycen Wiacek; Ole Marius Hoel Rindal; Eniola Falomo; Kelly Myers; Kelly Fabrega-Foster; Susan Harvey; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-27       Impact factor: 2.725

2.  Improved Visualization in Difficult-to-Image Stress Echocardiography Patients Using Real-Time Harmonic Spatial Coherence Imaging.

Authors:  Dongwoon Hyun; Anna Lisa C Crowley; Melissa LeFevre; Jayne Cleve; Jarrett Rosenberg; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Ultrasonic multipath and beamforming clutter reduction: a chirp model approach.

Authors:  Brett Byram; Marko Jakovljevic
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

4.  Equivalence of time and aperture domain additive noise in ultrasound coherence.

Authors:  Nick B Bottenus; Gregg E Trahey
Journal:  J Acoust Soc Am       Date:  2015-01       Impact factor: 1.840

5.  Unsupervised clustering method to convert high-resolution magnetic resonance volumes to three-dimensional acoustic models for full-wave ultrasound simulations.

Authors:  Kevin Looby; Carl D Herickhoff; Christopher Sandino; Tao Zhang; Shreyas Vasanawala; Jeremy J Dahl
Journal:  J Med Imaging (Bellingham)       Date:  2019-07-22

6.  Local speed of sound estimation in tissue using pulse-echo ultrasound: Model-based approach.

Authors:  Marko Jakovljevic; Scott Hsieh; Rehman Ali; Gustavo Chau Loo Kung; Dongwoon Hyun; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2018-07       Impact factor: 1.840

7.  Coherent flow power Doppler (CFPD): flow detection using spatial coherence beamforming.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-06       Impact factor: 2.725

8.  Short-lag spatial coherence imaging on matrix arrays, part II: Phantom and in vivo experiments.

Authors:  Marko Jakovljevic; Brett C Byram; Dongwoon Hyun; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

9.  Short-lag spatial coherence imaging on matrix arrays, part 1: Beamforming methods and simulation studies.

Authors:  Dongwoon Hyun; Gregg E Trahey; Marko Jakovljevic; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

10.  A motion-based approach to abdominal clutter reduction.

Authors:  Muyinatu A Lediju; Michael J Pihl; Stephen J Hsu; Jeremy J Dahl; Caterina M Gallippi; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-11       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.