Literature DB >> 26067037

Coherent flow power Doppler (CFPD): flow detection using spatial coherence beamforming.

You Leo Li, Jeremy J Dahl.   

Abstract

Power Doppler imaging is a widely used method of flow detection for tissue perfusion monitoring, inflammatory hyperemia detection, deep vein thrombosis diagnosis, and other clinical applications. However, thermal noise and clutter limit its sensitivity and ability to detect slow flow. In addition, large ensembles are required to obtain sufficient sensitivity, which limits frame rate and yields flash artifacts during moderate tissue motion. We propose an alternative method of flow detection using the spatial coherence of backscattered ultrasound echoes. The method enhances slow flow detection and frame rate, while maintaining or improving the signal quality of conventional power Doppler techniques. The feasibility of this method is demonstrated with simulations, flow-phantom experiments, and an in vivo human thyroid study. In comparison with conventional power Doppler imaging, the proposed method can produce Doppler images with 15- to 30-dB SNR improvement. Therefore, the method is able to detect flow with velocities approximately 50% lower than conventional power Doppler, or improve the frame rate by a factor of 3 with comparable image quality. The results show promise for clinical applications of the method.

Entities:  

Mesh:

Year:  2015        PMID: 26067037      PMCID: PMC4467462          DOI: 10.1109/TUFFC.2014.006793

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  30 in total

1.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

2.  Functional ultrasound imaging of the brain.

Authors:  Emilie Macé; Gabriel Montaldo; Ivan Cohen; Michel Baulac; Mathias Fink; Mickael Tanter
Journal:  Nat Methods       Date:  2011-07-03       Impact factor: 28.547

3.  Speckle coherence and implications for adaptive imaging.

Authors:  W F Walker; G E Trahey
Journal:  J Acoust Soc Am       Date:  1997-04       Impact factor: 1.840

4.  Ultrafast Doppler reveals the mapping of cerebral vascular resistivity in neonates.

Authors:  Charlie Demené; Mathieu Pernot; Valérie Biran; Marianne Alison; Mathias Fink; Olivier Baud; Mickaël Tanter
Journal:  J Cereb Blood Flow Metab       Date:  2014-03-26       Impact factor: 6.200

5.  Diagnosis of lower limb venous thrombosis by Doppler ultrasound technique.

Authors:  B Sigel; W R Felix; G L Popky; J Ipsen
Journal:  Arch Surg       Date:  1972-02

6.  Functional ultrasound imaging of the brain: theory and basic principles.

Authors:  Emilie Mace; Gabriel Montaldo; Bruno-Felix Osmanski; Ivan Cohen; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

7.  Sensitive noninvasive monitoring of tumor perfusion during antiangiogenic therapy by intermittent bolus-contrast power Doppler sonography.

Authors:  Martin Krix; Fabian Kiessling; Silvia Vosseler; Nabeel Farhan; Margareta M Mueller; Peter Bohlen; Norbert E Fusenig; Stefan Delorme
Journal:  Cancer Res       Date:  2003-12-01       Impact factor: 12.701

8.  Sonographic assessment of carotid artery stenosis. Comparison of power Doppler imaging and color Doppler flow imaging.

Authors:  W Steinke; S Meairs; S Ries; M Hennerici
Journal:  Stroke       Date:  1996-01       Impact factor: 7.914

9.  The use of power Doppler ultrasound in the diagnosis of isolated deep venous thrombosis of the calf.

Authors:  K Forbes; A J Stevenson
Journal:  Clin Radiol       Date:  1998-10       Impact factor: 2.350

Review 10.  A systematic review of the accuracy of ultrasound in the diagnosis of deep venous thrombosis in asymptomatic patients.

Authors:  Behrouz Kassaï; Jean-Pierre Boissel; Michel Cucherat; Sandrine Sonie; Nirav R Shah; Alain Leizorovicz
Journal:  Thromb Haemost       Date:  2004-04       Impact factor: 5.249

View more
  18 in total

1.  Debiasing-Based Noise Suppression for Ultrafast Ultrasound Microvessel Imaging.

Authors:  Chengwu Huang; Pengfei Song; Ping Gong; Joshua D Trzasko; Armando Manduca; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-05-22       Impact factor: 2.725

2.  Angular coherence in ultrasound imaging: Theory and applications.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2017-03       Impact factor: 1.840

3.  Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler.

Authors:  You Leo Li; Dongwoon Hyun; Lotfi Abou-Elkacem; Juergen Karl Willmann; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11       Impact factor: 2.725

4.  Combining Slow Flow Techniques With Adaptive Demodulation for Improved Perfusion Ultrasound Imaging Without Contrast.

Authors:  Jaime Tierney; Kristy Walsh; Helen Griffith; Jennifer Baker; Daniel B Brown; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-02-07       Impact factor: 2.725

5.  Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging.

Authors:  Jaime Tierney; Crystal Coolbaugh; Theodore Towse; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2017-06-13       Impact factor: 10.048

6.  Coherent Multi-Transducer Ultrasound Imaging.

Authors:  Laura Peralta; Alberto Gomez; Ying Luan; Bae-Hyung Kim; Joseph V Hajnal; Robert J Eckersley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-05       Impact factor: 2.725

7.  A Spatial Coherence Beamformer Design for Power Doppler Imaging.

Authors:  Kathryn Ozgun; Jaime Tierney; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2019-11-14       Impact factor: 10.048

8.  High Resolution Ultrasound Superharmonic Perfusion Imaging: In Vivo Feasibility and Quantification of Dynamic Contrast-Enhanced Acoustic Angiography.

Authors:  Brooks D Lindsey; Sarah E Shelton; K Heath Martin; Kathryn A Ozgun; Juan D Rojas; F Stuart Foster; Paul A Dayton
Journal:  Ann Biomed Eng       Date:  2016-11-10       Impact factor: 3.934

9.  Efficient Strategies for Estimating the Spatial Coherence of Backscatter.

Authors:  Dongwoon Hyun; Anna Lisa C Crowley; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-12-01       Impact factor: 2.725

10.  Lag-One Coherence as a Metric for Ultrasonic Image Quality.

Authors:  Will Long; Nick Bottenus; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07-12       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.