Literature DB >> 3809241

The development of harmonic distortion in pulsed finite-amplitude ultrasound passing through liver.

H C Starritt, F A Duck, A J Hawkins, V F Humphrey.   

Abstract

The progressive development of finite-amplitude distortion of ultrasonic pulses has been investigated in excised bovine liver using pulsed focused ultrasonic beams at nominal frequencies of 2.5 and 3.5 MHz. Both the transducers and the powers used were those which may be encountered with clinical imaging equipment. Significant distortion of the waveform was observed to occur, particularly at higher powers. For example, at 2.5 MHz, with a mean input pressure (p0) of 0.58 MPa, the second harmonic in the pulse spectrum showed a maximum value of 10.5 dB below the fundamental and the highest third harmonic component was 19 dB below the fundamental. These particular observations illustrate that finite-amplitude distortion may be of considerable significance in the transmission through tissue of ultrasonic pulses during diagnostic scanning.

Entities:  

Mesh:

Year:  1986        PMID: 3809241     DOI: 10.1088/0031-9155/31/12/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Simulation of nonlinear propagation of biomedical ultrasound using pzflex and the Khokhlov-Zabolotskaya-Kuznetsov Texas code.

Authors:  Shan Qiao; Edward Jackson; Constantin C Coussios; Robin O Cleveland
Journal:  J Acoust Soc Am       Date:  2016-09       Impact factor: 1.840

Review 2.  Superharmonic Imaging for Medical Ultrasound: a Review.

Authors:  Narendra D Londhe; Jasjit S Suri
Journal:  J Med Syst       Date:  2016-10-27       Impact factor: 4.460

3.  Medical ultrasound systems.

Authors:  Jeff Powers; Frederick Kremkau
Journal:  Interface Focus       Date:  2011-05-18       Impact factor: 3.906

4.  Effects of dual apodization with cross-correlation on tissue harmonic and pulse inversion harmonic imaging in the presence of phase aberration.

Authors:  Junseob Shin; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

5.  Analyzing the Impact of Increasing Mechanical Index and Energy Deposition on Shear Wave Speed Reconstruction in Human Liver.

Authors:  Yufeng Deng; Mark L Palmeri; Ned C Rouze; Stephen J Rosenzweig; Manal F Abdelmalek; Kathryn R Nightingale
Journal:  Ultrasound Med Biol       Date:  2015-04-18       Impact factor: 2.998

6.  Enhanced methods for visualizing myocardial perfusion with peripheral venous injection of levovist: application of triggered harmonic imaging and triggered harmonic power Doppler imaging techniques.

Authors:  K Hirooka; K Miyatake; A Hanatani; K Komamura; S Nakatani; Y Yasumura; M Yamagishi
Journal:  Int J Card Imaging       Date:  2000-08

7.  Quantitative assessment of the magnitude, impact and spatial extent of ultrasonic clutter.

Authors:  Muyinatu A Lediju; Michael J Pihl; Jeremy J Dahl; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2008-07       Impact factor: 1.578

8.  Phase-inversion tissue harmonic imaging compared with conventional B-mode ultrasound in the evaluation of pancreatic lesions.

Authors:  Christian Hohl; Thorsten Schmidt; Patrick Haage; Dagmar Honnef; Marcus Blaum; Gundula Staatz; Rolf W Guenther
Journal:  Eur Radiol       Date:  2004-01-09       Impact factor: 5.315

9.  Short-lag spatial coherence imaging of cardiac ultrasound data: initial clinical results.

Authors:  Muyinatu A Lediju Bell; Robi Goswami; Joseph A Kisslo; Jeremy J Dahl; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2013-08-09       Impact factor: 2.998

10.  Role of clinical judgment and tissue harmonic imaging ultrasonography in diagnosis of paediatric acute appendicitis.

Authors:  Ossama Zakaria; Tamer A Sultan; Tarek H Khalil; Tamer Wahba
Journal:  World J Emerg Surg       Date:  2011-11-16       Impact factor: 5.469

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.