Literature DB >> 19142849

Artifacts in Fourier transform mass spectrometry.

Raman Mathur1, Peter B O'Connor.   

Abstract

Recent work on a new, higher sensitivity preamplifier design for Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) revealed a number of artifact peaks (spectral features) which do not contain useful chemical information. In order to determine the cause of these artifacts and eliminate them, these severely distorted spectra were compared with similarly distorted signal models. The source of several common signal processing artifacts was thereby determined and correlated to radio-frequency interference (RFI) noise and saturation of the amplifier and/or the digitizer. Under such conditions, the fast Fourier transform (FFT) generates spectral artifact peaks corresponding to harmonics and mixing frequencies of the real signal peaks and RFI frequencies. While this study was done using FTICRMS data, it is important to stress that these artifacts are inherent to the digitization and FFT process and thus are relevant to any FT-based MS instrument, including the orbitrap and FT ion trap. Copyright 2009 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2009        PMID: 19142849      PMCID: PMC2872032          DOI: 10.1002/rcm.3904

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  13 in total

1.  Protein analysis by mass spectrometry and sequence database searching: tools for cancer research in the post-genomic era.

Authors:  S P Gygi; D K Han; A C Gingras; N Sonenberg; R Aebersold
Journal:  Electrophoresis       Date:  1999-02       Impact factor: 3.535

Review 2.  Mass spectrometry in proteomics.

Authors:  R Aebersold; D R Goodlett
Journal:  Chem Rev       Date:  2001-02       Impact factor: 60.622

3.  A high pressure matrix-assisted laser desorption ion source for Fourier transform mass spectrometry designed to accommodate large targets with diverse surfaces.

Authors:  Peter B O'Connor; Bogdan A Budnik; Vera B Ivleva; Parminder Kaur; Susanne C Moyer; Jason L Pittman; Catherine E Costello
Journal:  J Am Soc Mass Spectrom       Date:  2004-01       Impact factor: 3.109

4.  The Orbitrap: a new mass spectrometer.

Authors:  Qizhi Hu; Robert J Noll; Hongyan Li; Alexander Makarov; Mark Hardman; R Graham Cooks
Journal:  J Mass Spectrom       Date:  2005-04       Impact factor: 1.982

5.  A low-noise, wideband preamplifier for a Fourier-transform ion cyclotron resonance mass spectrometer.

Authors:  Raman Mathur; Ronald W Knepper; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2007-09-29       Impact factor: 3.109

6.  Two-dimensional coulomb-induced frequency modulation in Fourier transform ion cyclotron resonance: A mechanism for line broadening at high mass and for large ion populations.

Authors:  C L Hendrickson; S C Beu; D A Laude
Journal:  J Am Soc Mass Spectrom       Date:  1993-12       Impact factor: 3.109

7.  Routine Part-per-Million Mass Accuracy for High- Mass Ions:  Space-Charge Effects in MALDI FT-ICR.

Authors:  M L Easterling; T H Mize; I J Amster
Journal:  Anal Chem       Date:  1999-02-01       Impact factor: 6.986

8.  Broad-band fourier transform quadrupole ion trap mass spectrometry.

Authors:  M Soni; V Frankevich; M Nappi; R E Santini; J W Amy; R G Cooks
Journal:  Anal Chem       Date:  1996-10-01       Impact factor: 6.986

9.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

10.  Proteomic analysis of the mammalian nuclear pore complex.

Authors:  Janet M Cronshaw; Andrew N Krutchinsky; Wenzhu Zhang; Brian T Chait; Michael J Matunis
Journal:  J Cell Biol       Date:  2002-08-26       Impact factor: 10.539

View more
  9 in total

1.  A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry.

Authors:  Tzu-Yung Lin; Roger J Green; Peter B O'Connor
Journal:  Rev Sci Instrum       Date:  2011-12       Impact factor: 1.523

2.  Using fragmentation trees and mass spectral trees for identifying unknown compounds in metabolomics.

Authors:  Arpana Vaniya; Oliver Fiehn
Journal:  Trends Analyt Chem       Date:  2015-06-01       Impact factor: 12.296

3.  A Miniaturized Fourier Transform Electrostatic Linear Ion Trap Mass Spectrometer: Mass Range and Resolution.

Authors:  Joshua T Johnson; Kenneth W Lee; Jay S Bhanot; Scott A McLuckey
Journal:  J Am Soc Mass Spectrom       Date:  2019-02-12       Impact factor: 3.109

4.  Mass spectral peak distortion due to Fourier transform signal processing.

Authors:  Alan L Rockwood; John C L Erve
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-27       Impact factor: 3.109

Review 5.  Isobaric labeling-based relative quantification in shotgun proteomics.

Authors:  Navin Rauniyar; John R Yates
Journal:  J Proteome Res       Date:  2014-11-04       Impact factor: 4.466

6.  New methods to identify high peak density artifacts in Fourier transform mass spectra and to mitigate their effects on high-throughput metabolomic data analysis.

Authors:  Joshua M Mitchell; Robert M Flight; Qing Jun Wang; Richard M Higashi; Teresa W-M Fan; Andrew N Lane; Hunter N B Moseley
Journal:  Metabolomics       Date:  2018-09-17       Impact factor: 4.290

Review 7.  A tutorial in small molecule identification via electrospray ionization-mass spectrometry: The practical art of structural elucidation.

Authors:  Thomas De Vijlder; Dirk Valkenborg; Filip Lemière; Edwin P Romijn; Kris Laukens; Filip Cuyckens
Journal:  Mass Spectrom Rev       Date:  2017-11-09       Impact factor: 10.946

8.  Fragmentation trees for the structural characterisation of metabolites.

Authors:  Piotr T Kasper; Miguel Rojas-Chertó; Robert Mistrik; Theo Reijmers; Thomas Hankemeier; Rob J Vreeken
Journal:  Rapid Commun Mass Spectrom       Date:  2012-10-15       Impact factor: 2.419

9.  Evaluation of Sibling and Twin Fragment Ions Improves the Structural Characterization of Proteins by Top-Down MALDI In-Source Decay Mass Spectrometry.

Authors:  Simone Nicolardi; David P A Kilgour; Natasja Dolezal; Jan W Drijfhout; Manfred Wuhrer; Yuri E M van der Burgt
Journal:  Anal Chem       Date:  2020-04-02       Impact factor: 6.986

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.