Literature DB >> 22225232

A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry.

Tzu-Yung Lin1, Roger J Green, Peter B O'Connor.   

Abstract

The nature of the ion signal from a 12-T Fourier-transform ion cyclotron resonance mass spectrometer and the electronic noise were studied to further understand the electronic detection limit. At minimal cost, a new transimpedance preamplifier was designed, computer simulated, built, and tested. The preamplifier design pushes the electronic signal-to-noise performance at room temperature to the limit, because of its enhanced tolerance of the capacitance of the detection device, lower intrinsic noise, and larger flat mid-band gain (input current noise spectral density of around 1 pA/√Hz when the transimpedance is about 85 dBΩ). The designed preamplifier has a bandwidth of ~3 kHz to 10 MHz, which corresponds to the mass-to-charge ratio, m/z, of approximately 18 to 61 k at 12 T. The transimpedance and the bandwidth can be easily adjusted by changing the value of passive components. The feedback limitation of the circuit is discussed. With the maximum possible transimpedance of 5.3 MΩ when using an 0402 surface mount resistor, the preamplifier was estimated to be able to detect ~110 charges in a single scan.

Mesh:

Year:  2011        PMID: 22225232      PMCID: PMC3253747          DOI: 10.1063/1.3660778

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  19 in total

1.  Considerations for design of a Fourier transform mass spectrometer in the 4.2 K cold bore of a superconducting magnet.

Authors:  Peter B O'Connor
Journal:  Rapid Commun Mass Spectrom       Date:  2002       Impact factor: 2.419

2.  Fourier transform ion cyclotron resonance mass spectrometer with coaxial multi-electrode cell ('O-trap'): first experimental demonstration.

Authors:  A S Misharin; R A Zubarev; V M Doroshenko
Journal:  Rapid Commun Mass Spectrom       Date:  2010-07-30       Impact factor: 2.419

3.  Artifacts in Fourier transform mass spectrometry.

Authors:  Raman Mathur; Peter B O'Connor
Journal:  Rapid Commun Mass Spectrom       Date:  2009-02       Impact factor: 2.419

4.  The 'hybrid cell': a new compensated infinity cell for larger radius ion excitation in Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Sunghwan Kim; Myoung Choul Choi; Manhoi Hur; Hyun Sik Kim; Jong Shin Yoo; Christopher L Hendrickson; Alan G Marshall
Journal:  Rapid Commun Mass Spectrom       Date:  2008-05       Impact factor: 2.419

Review 5.  Fourier transform ion cyclotron resonance mass spectrometry: a primer.

Authors:  A G Marshall; C L Hendrickson; G S Jackson
Journal:  Mass Spectrom Rev       Date:  1998 Jan-Feb       Impact factor: 10.946

6.  Excite-coupled trapping ring electrode cell (eTREC): radial trapping field control, linearized excitation, and improved detection.

Authors:  Chad R Weisbrod; Nathan K Kaiser; Gunnar E Skulason; James E Bruce
Journal:  Anal Chem       Date:  2010-07-15       Impact factor: 6.986

Review 7.  Peptide and protein imaging mass spectrometry in cancer research.

Authors:  Liam A McDonnell; Garry L Corthals; Stefan M Willems; Alexandra van Remoortere; René J M van Zeijl; André M Deelder
Journal:  J Proteomics       Date:  2010-05-25       Impact factor: 4.044

8.  Unusual fragmentation of β-linked peptides by ExD tandem mass spectrometry.

Authors:  Nadezda P Sargaeva; Cheng Lin; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-29       Impact factor: 3.109

9.  Structural heterogeneity of doubly-charged peptide b-ions.

Authors:  Xiaojuan Li; Yiqun Huang; Peter B O'Connor; Cheng Lin
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-29       Impact factor: 3.109

10.  An external matrix-assisted laser desorption ionization source for flexible FT-ICR Mass spectrometry imaging with internal calibration on adjacent samples.

Authors:  Donald F Smith; Konstantin Aizikov; Marc C Duursma; Frans Giskes; Dirk-Jan Spaanderman; Liam A McDonnell; Peter B O'Connor; Ron M A Heeren
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-20       Impact factor: 3.109

View more
  1 in total

1.  A low noise single-transistor transimpedance preamplifier for Fourier-transform mass spectrometry using a T feedback network.

Authors:  Tzu-Yung Lin; Roger J Green; Peter B O'Connor
Journal:  Rev Sci Instrum       Date:  2012-09       Impact factor: 1.523

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.