| Literature DB >> 30830442 |
Joshua M Mitchell1,2,3, Robert M Flight2,3, Qing Jun Wang2,4, Richard M Higashi2,3,5, Teresa W-M Fan2,3,5, Andrew N Lane2,3,5, Hunter N B Moseley6,7,8,9.
Abstract
INTRODUCTION: Direct injection Fourier-transform mass spectrometry (FT-MS) allows for the high-throughput and high-resolution detection of thousands of metabolite-associated isotopologues. However, spectral artifacts can generate large numbers of spectral features (peaks) that do not correspond to known compounds. Misassignment of these artifactual features creates interpretive errors and limits our ability to discern the role of representative features within living systems.Entities:
Keywords: Artifact; Data analysis; Fourier transform; Mass spectrometry; Metabolomics
Mesh:
Year: 2018 PMID: 30830442 PMCID: PMC6153687 DOI: 10.1007/s11306-018-1426-9
Source DB: PubMed Journal: Metabolomics ISSN: 1573-3882 Impact factor: 4.290
Fig. 1Automated HPD-site detection. The HPD artifact detection algorithm in three steps: first, a peak density metric is calculated for the spectrum using a sliding window method (1 m/z window, 0.1 m/z increment); second, a set of N + 1 windows and the peak density metric are used to calculate a peak density statistic for each portion of the spectrum. This metric flattens out density differences due to signal-to-noise differences or baseline differences and highlights spectra with HPD artifacts (Fig. 3e–h). Filtering this metric reveals the location of the HPD artifacts
Fig. 3Peak density and peak density statistics. Peak density metric and statistic plots produced by our HPD-detector tool highlight the impact of the instrument on peak density and HPD artifact location. All instruments have higher peak densities at lower m/z, representing trends in signal-to-noise and digitization with respect to m/z in FT-MS. The sharp spikes in peak density correspond to HPD artifacts. The locations of these spikes on Fusion 1 are different before and after the firmware update (a, b), suggesting instrument-level data processing is related to HPD generation. e–h show the effectiveness of our peak density statistic metric for flattening the non-constant baseline observed in plots of the raw peak density. Without this correction, identifying HPD regions reliably is difficult. a–c, e–g were generated from spectra acquired using sample C. d and h were generated from spectra acquired using sample E
Fig. 2Three types of HPD artifacts. We observed three subclasses of HPD artifacts. The first is the fuzzy site (a, sample D), which we believe is a novel artifact type. The second is ringing, a well-known FT-MS artifact where a single intense peak has many side peaks (b, sample B). We only observed ringing at the scan level. The third artifact is partial ringing which is a ringing-like artifact at the aggregate level (c, sample A). R is the resolution setting used for data acquisition, µS is the microscan setting, and N is the number of scans aggregated to create the spectrum
Fig. 4Fuzzy sites at the Aggregate and Scan Level. A typical fuzzy site a occupies 0.5–3 m/z at the aggregate level and has a distinct ‘fuzzy’ appearance due to very high peak density (this image is identical to Fig. 2a). At the scan level, only a subdomain of the m/z occupied by the fuzzy site contains peaks; the subdomain with peaks varies from scan-to-scan (b). As increasingly more scans are aggregated together, the peak distribution converges to the pattern observed at the aggregate level (c). All panels were generated using sample A. R is the resolution setting used for the acquisition, µS is the microscan setting, and N is the number of scans aggregated to create the spectrum
Fig. 6Example fuzzy site locations that vary with sample class. The location of fuzzy sites in spectra from the same biological unit can differ significantly based on sample class (cancer vs. non-cancer). a and b illustrates one fuzzy site whose location varies by rough 2 m/z between sample class. c and d shows a single fuzzy site whose location varies by over 12 m/z between sample class
Fig. 5HPD regions depend on biological unit, sample class, and instrument