Literature DB >> 27696286

Radiation dose optimization for the bolus tracking technique in abdominal computed tomography: usefulness of real-time iterative reconstruction for monitoring scan.

Yuya Ishikawa1, Atsushi Urikura2, Tsukasa Yoshida2, Keisuke Takiguchi2, Yoshihiro Nakaya2.   

Abstract

The purpose of this study was to optimize the monitoring dose, obtained using the conventional filtered back projection (FBP) method and iterative reconstruction algorithms, for the bolus tracking technique. A phantom study was performed to assess the effect of the scan start time in patients grouped according to different body weights. An oval torso phantom was used for simulating the time enhancement curve of the bolus tracking technique. To reproduce image noise levels in the two body weight groups, the phantom diameter was adjusted with a water-equivalent material. The tube currents were 10, 20, 30, and 50 mA. The monitoring scan was performed with the conventional FBP method and real-time adaptive iterative dose reduction by three-dimensional processing (AIDR 3D). The results at different doses were compared with those at 50 mA. The volume computed tomography dose index was 1.31, 2.65, 3.93, and 6.56 mGy at tube currents of 10, 20, 30, and 50 mA, respectively. The scan start time, reconstructed using FBP, was significantly faster at 10 and 20 mA in group A (50-59 kg) and at 20 mA in group B (≥80 kg). The CT values in the region of interest could not be measured at 10 mA because of artifacts. With real-time AIDR 3D, both groups showed no significant differences between the measurements obtained at 30 or 20 mA and those obtained at 50 mA. Our study demonstrated that the real-time AIDR 3D algorithm improved the accuracy of the CT measurements with the bolus tracking technique.

Entities:  

Keywords:  Bolus tracking; Computed tomography; Contrast media; Iterative reconstruction; Radiation dose

Mesh:

Year:  2016        PMID: 27696286     DOI: 10.1007/s12194-016-0378-x

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  20 in total

1.  Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT.

Authors:  J J Sandstede; A Tschammler; M Beer; C Vogelsang; G Wittenberg; D Hahn
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

2.  Initial experience with a chest pain protocol using 320-slice volume MDCT.

Authors:  Patrick A Hein; Valentina C Romano; Alexander Lembcke; Juliane May; Patrik Rogalla
Journal:  Eur Radiol       Date:  2009-01-10       Impact factor: 5.315

3.  Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels.

Authors:  A Löve; M-L Olsson; R Siemund; F Stålhammar; I M Björkman-Burtscher; M Söderberg
Journal:  Br J Radiol       Date:  2013-09-18       Impact factor: 3.039

Review 4.  Optimizing radiation dose and image quality.

Authors:  Carlo Catalano; Marco Francone; Adriano Ascarelli; Matteo Mangia; Ilaria Iacucci; Roberto Passariello
Journal:  Eur Radiol       Date:  2007-12       Impact factor: 5.315

5.  Optimizing liver contrast in helical liver CT: value of a real-time bolus-triggering technique.

Authors:  H P Dinkel; M Fieger; J Knüpffer; R Moll; G Schindler
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

6.  Spatial resolution measurement for iterative reconstruction by use of image-averaging techniques in computed tomography.

Authors:  Atsushi Urikura; Katsuhiro Ichikawa; Takanori Hara; Eiji Nishimaru; Yoshihiro Nakaya
Journal:  Radiol Phys Technol       Date:  2014-06-01

7.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

8.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Jiang Hsieh; Paul E Licato; Synho Do; Homer H Pien; Michael A Blake
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

9.  Reduction of interpatient variability of arterial enhancement using a new bolus tracking system in 320-detector computed tomographic coronary angiography.

Authors:  Fuminari Tatsugami; Kazuo Awai; Haruhiko Takada; Shushi Yoshikawa; Yoshihiro Takeda; Hideaki Morita; Yoshifumi Narumi
Journal:  J Comput Assist Tomogr       Date:  2013 Jan-Feb       Impact factor: 1.826

Review 10.  Abdominal MDCT: protocols and contrast considerations.

Authors:  Renate M Hammerstingl; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-12       Impact factor: 5.315

View more