Literature DB >> 20087606

Evaluation of swallowing using 320-detector-row multislice CT. Part I: single- and multiphase volume scanning for three-dimensional morphological and kinematic analysis.

Naoko Fujii1, Yoko Inamoto, Eiichi Saitoh, Mikoto Baba, Sumiko Okada, Satoshi Yoshioka, Toshiaki Nakai, Yoshihiro Ida, Kazuhiro Katada, Jeffrey B Palmer.   

Abstract

A 320-detector-row multislice computed tomography (320-MSCT) scanner can acquire a volume data set covering a maximum range of 16 cm and can generate axial images 0.5-mm thick at 0.5-mm intervals. Three-dimensional (3D) images reconstructed from the thin axial slices include multiplanar reconstruction and 3D-CT. Single-phase 3D images are reconstructed from 0.175-s data, and multiphase 3D images are created in 29 phases at intervals of 0.1 s. Continuous replay of these 3D images produces four-dimensional moving images. In order to determine the feasibility of the morphologic and kinematic analyses of swallowing using 320-MSCT, single-phase volume scanning was performed on three patients and multiphase volume scanning was performed on one healthy volunteer. The single-phase 3D images clearly and accurately showed the structures involved in swallowing, and the multiphase 3D images were able to show the oral stage to the early esophageal stage of swallowing, allowing a kinematic analysis of swallowing. We developed a reclining chair that allows scanning to be performed with the subject in a semisitting position, which makes swallowing evaluation by 320-MSCT applicable not only to research on healthy swallowing but also to the clinical examination of dysphagia patients.

Entities:  

Mesh:

Year:  2010        PMID: 20087606     DOI: 10.1007/s00455-009-9268-2

Source DB:  PubMed          Journal:  Dysphagia        ISSN: 0179-051X            Impact factor:   3.438


  22 in total

1.  Radiation dose in videofluoroscopic swallow studies.

Authors:  Ivan Zammit-Maempel; Claire-Louise Chapple; Paula Leslie
Journal:  Dysphagia       Date:  2006-10-06       Impact factor: 3.438

2.  Initial experience with a chest pain protocol using 320-slice volume MDCT.

Authors:  Patrick A Hein; Valentina C Romano; Alexander Lembcke; Juliane May; Patrik Rogalla
Journal:  Eur Radiol       Date:  2009-01-10       Impact factor: 5.315

3.  Patterns of lingual tissue deformation associated with bolus containment and propulsion during deglutition as determined by echo-planar MRI.

Authors:  R J Gilbert; S Daftary; T A Campbell; R M Weisskoff
Journal:  J Magn Reson Imaging       Date:  1998 May-Jun       Impact factor: 4.813

4.  Technical note: dynamic analysis of the pharynx during swallowing using Turbo-FLASH magnetic resonance imaging combined with an oral positive contrast agent--a preliminary study.

Authors:  Y Suto; M Kamba; T Kato
Journal:  Br J Radiol       Date:  1995-10       Impact factor: 3.039

5.  Patient and operator dose during fluoroscopic examination of swallow mechanism.

Authors:  M T Crawley; P Savage; F Oakley
Journal:  Br J Radiol       Date:  2004-08       Impact factor: 3.039

6.  Whole-brain perfusion CT performed with a prototype 256-detector row CT system: initial experience.

Authors:  Kazuhiro Murayama; Kazuhiro Katada; Masato Nakane; Hiroshi Toyama; Hirofumi Anno; Motoharu Hayakawa; Diego San Millan Ruiz; Kieran J Murphy
Journal:  Radiology       Date:  2009-01       Impact factor: 11.105

7.  Morphologic parameters of normal swallowing events using single-shot fast spin echo dynamic MRI.

Authors:  Dana M Hartl; Marcella Albiter; Frédéric Kolb; Bernard Luboinski; Robert Sigal
Journal:  Dysphagia       Date:  2003       Impact factor: 3.438

8.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007

9.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

10.  4-D Imaging in cerebrovascular disorders by using 320-slice CT: feasibility and preliminary clinical experience.

Authors:  Randolf Klingebiel; Eberhard Siebert; Susanne Diekmann; Edzard Wiener; Florian Masuhr; Moritz Wagner; Hans-Christian Bauknecht; Marc Dewey; G Bohner
Journal:  Acad Radiol       Date:  2009-02       Impact factor: 3.173

View more
  14 in total

1.  The effect of bolus viscosity on laryngeal closure in swallowing: kinematic analysis using 320-row area detector CT.

Authors:  Yoko Inamoto; Eiichi Saitoh; Sumiko Okada; Hitoshi Kagaya; Seiko Shibata; Kikuo Ota; Mikoto Baba; Naoko Fujii; Kazuhiro Katada; Pattra Wattanapan; Jeffrey B Palmer
Journal:  Dysphagia       Date:  2012-06-05       Impact factor: 3.438

Review 2.  Assessing Upper Esophageal Sphincter Function in Clinical Practice: a Primer.

Authors:  Nitin K Ahuja; Walter W Chan
Journal:  Curr Gastroenterol Rep       Date:  2016-02

3.  Evaluation of swallowing using 320-detector-row multislice CT. Part II: kinematic analysis of laryngeal closure during normal swallowing.

Authors:  Yoko Inamoto; Naoko Fujii; Eiichi Saitoh; Mikoto Baba; Sumiko Okada; Kazuhiro Katada; Yasunori Ozeki; Daisuke Kanamori; Jeffrey B Palmer
Journal:  Dysphagia       Date:  2010-03-05       Impact factor: 3.438

4.  Temporal and Physiologic Measurements of Deglutition in the Upright and Supine Position with Videofluoroscopy (VFS) in Healthy Subjects.

Authors:  H K Su; A Khorsandi; J Silberzweig; A J Kobren; M L Urken; M R Amin; R C Branski; C L Lazarus
Journal:  Dysphagia       Date:  2015-05-13       Impact factor: 3.438

5.  The Association of 3-D Volume and 2-D Area of Post-swallow Pharyngeal Residue on CT Imaging.

Authors:  Rachel W Mulheren; Yoko Inamoto; Charles A Odonkor; Yuriko Ito; Seiko Shibata; Hitoshi Kagaya; Marlis Gonzalez-Fernandez; Eiichi Saitoh; Jeffrey B Palmer
Journal:  Dysphagia       Date:  2019-01-14       Impact factor: 3.438

6.  Changes in pyriform sinus morphology in the head rotated position as assessed by 320-row area detector CT.

Authors:  Enri Nakayama; Hitoshi Kagaya; Eiichi Saitoh; Yoko Inamoto; Shuji Hashimoto; Naoko Fujii; Kazuhiro Katada; Daisuke Kanamori; Haruka Tohara; Koichiro Ueda
Journal:  Dysphagia       Date:  2012-11-03       Impact factor: 3.438

7.  Measurement of Pharyngo-laryngeal Volume During Swallowing Using 320-Row Area Detector Computed Tomography.

Authors:  Takatoshi Iida; Hitoshi Kagaya; Yoko Inamoto; Seiko Shibata; Eiichi Saitoh; Daisuke Kanamori; Shuji Hashimoto; Kazuhiro Katada; Haruka Tohara; Koichiro Ueda
Journal:  Dysphagia       Date:  2017-07-03       Impact factor: 3.438

8.  Evaluation of patient dose and operator dose in swallowing CT studies performed with a 320-detector-row multislice CT scanner.

Authors:  Masanao Kobayashi; Kichiro Koshida; Shoichi Suzuki; Kazuhiro Katada
Journal:  Radiol Phys Technol       Date:  2012-03-04

9.  Ingestible roasted barley for contrast-enhanced photoacoustic imaging in animal and human subjects.

Authors:  Depeng Wang; Dong Hyeun Lee; Haoyuan Huang; Tri Vu; Rachel Su Ann Lim; Nikhila Nyayapathi; Upendra Chitgupi; Maggie Liu; Jumin Geng; Jun Xia; Jonathan F Lovell
Journal:  Biomaterials       Date:  2018-05-17       Impact factor: 12.479

10.  Dysphagia Rehabilitation: Similarities and Differences in Three Areas of the World.

Authors:  Marlís González-Fernández; Maggi-Lee Huckabee; Sebastian H Doeltgen; Yoko Inamoto; Hitoshi Kagaya; Eichii Saitoh
Journal:  Curr Phys Med Rehabil Rep       Date:  2013-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.