OBJECTIVES: The aim of this study was to determine the accuracy and reliability of shoulder magnetic resonance (MR) arthrography with three-dimensional (3D) isotropic intermediate-weighted turbo spin-echo (TSE) sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) in the diagnosis of superior labrum anterior-to-posterior (SLAP) lesions compared with two-dimensional (2D) TSE at 3.0 T. METHODS: MR arthrograms, including 2D TSE and 3D TSE-SPACE, in 87 patients who underwent arthroscopy were retrospectively analysed by two reviewers for the presence and type of SLAP lesions. Sensitivity and specificity were compared using McNemar's test, and inter-observer agreement was calculated using Cohen's kappa. Receiver operating characteristic (ROC) curve analyses were performed. RESULTS: The mean sensitivity, specificity and accuracy were 90%, 85% and 86% for 2D TSE, and 81%, 86% and 85% for 3D TSE-SPACE respectively, with no statistically significant differences. Inter-observer agreements were substantial in 2D TSE (κ = 0.76) and 3D TSE-SPACE (κ = 0.68). The areas under the ROC curves were 0.92 for 2D TSE and 0.90 for 3D TSE-SPACE, which were not significantly different. CONCLUSIONS: MR arthrography with 3D TSE-SPACE showed comparable accuracy and substantial inter-observer agreement for the diagnosis of SLAP lesions.
OBJECTIVES: The aim of this study was to determine the accuracy and reliability of shoulder magnetic resonance (MR) arthrography with three-dimensional (3D) isotropic intermediate-weighted turbo spin-echo (TSE) sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) in the diagnosis of superior labrum anterior-to-posterior (SLAP) lesions compared with two-dimensional (2D) TSE at 3.0 T. METHODS: MR arthrograms, including 2D TSE and 3D TSE-SPACE, in 87 patients who underwent arthroscopy were retrospectively analysed by two reviewers for the presence and type of SLAP lesions. Sensitivity and specificity were compared using McNemar's test, and inter-observer agreement was calculated using Cohen's kappa. Receiver operating characteristic (ROC) curve analyses were performed. RESULTS: The mean sensitivity, specificity and accuracy were 90%, 85% and 86% for 2D TSE, and 81%, 86% and 85% for 3D TSE-SPACE respectively, with no statistically significant differences. Inter-observer agreements were substantial in 2D TSE (κ = 0.76) and 3D TSE-SPACE (κ = 0.68). The areas under the ROC curves were 0.92 for 2D TSE and 0.90 for 3D TSE-SPACE, which were not significantly different. CONCLUSIONS: MR arthrography with 3D TSE-SPACE showed comparable accuracy and substantial inter-observer agreement for the diagnosis of SLAP lesions.
Authors: Simone Waldt; Andreas Burkart; Peter Lange; Andreas B Imhoff; Ernst J Rummeny; Klaus Woertler Journal: AJR Am J Roentgenol Date: 2004-05 Impact factor: 3.959
Authors: Oliver Ristow; Lynne Steinbach; Gregory Sabo; Roland Krug; Markus Huber; Isabel Rauscher; Ben Ma; Thomas M Link Journal: Eur Radiol Date: 2009-01-10 Impact factor: 5.315
Authors: Tobias Johannes Dietrich; Marco Zanetti; Nadja Saupe; Christian W A Pfirrmann; Sandro F Fucentese; Juerg Hodler Journal: Skeletal Radiol Date: 2009-12-17 Impact factor: 2.199
Authors: Ji Hyun Lee; Young Cheol Yoon; Sukkyung Jee; Jong Won Kwon; Jang Gyu Cha; Jae Chul Yoo Journal: Korean J Radiol Date: 2014-11-07 Impact factor: 3.500