Vivek Kalia1,2, Benjamin Fritz3, Rory Johnson4, Wesley D Gilson5, Esther Raithel6, Jan Fritz7. 1. Department of Radiology, University of Vermont Medical Center, 111 Colchester Ave, Burlington, VT, 05401, USA. 2. Russell H. Morgan Department of Radiology and Radiological Science, Section of Musculoskeletal Radiology, Johns Hopkins University School of Medicine, 601 N. Caroline Street, JHOC 3140A, Baltimore, MD, 21287, USA. 3. Department of Radiology, University Medical Center Freiburg, Robert-Koch-Straße 3, 79106, Freiburg im Breisgau, Germany. 4. Siemens Healthcare USA, Inc, 221 Gregson Drive, Cary, NC, 27511, USA. 5. Siemens Healthcare USA, Inc, 855 N Wolfe Street Suite 100, Baltimore, MD, 21205, USA. 6. Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052, Erlangen, Germany. 7. Russell H. Morgan Department of Radiology and Radiological Science, Section of Musculoskeletal Radiology, Johns Hopkins University School of Medicine, 601 N. Caroline Street, JHOC 3140A, Baltimore, MD, 21287, USA. jfritz9@jhmi.edu.
Abstract
OBJECTIVES: To test the hypothesis that a fourfold CAIPIRINHA accelerated, 10-min, high-resolution, isotropic 3D TSE MRI prototype protocol of the ankle derives equal or better quality than a 20-min 2D TSE standard protocol. METHODS: Following internal review board approval and informed consent, 3-Tesla MRI of the ankle was obtained in 24 asymptomatic subjects including 10-min 3D CAIPIRINHA SPACE TSE prototype and 20-min 2D TSE standard protocols. Outcome variables included image quality and visibility of anatomical structures using 5-point Likert scales. Non-parametric statistical testing was used. P values ≤0.001 were considered significant. RESULTS: Edge sharpness, contrast resolution, uniformity, noise, fat suppression and magic angle effects were without statistical difference on 2D and 3D TSE images (p > 0.035). Fluid was mildly brighter on intermediate-weighted 2D images (p < 0.001), whereas 3D images had substantially less partial volume, chemical shift and no pulsatile-flow artifacts (p < 0.001). Oblique and curved planar 3D images resulted in mildly-to-substantially improved visualization of joints, spring, bifurcate, syndesmotic, collateral and sinus tarsi ligaments, and tendons (p < 0.001, respectively). CONCLUSIONS: 3D TSE MRI with CAIPIRINHA acceleration enables high-spatial resolution oblique and curved planar MRI of the ankle and visualization of ligaments, tendons and joints equally well or better than a more time-consuming anisotropic 2D TSE MRI. KEY POINTS: • High-resolution 3D TSE MRI improves visualization of ankle structures. • Limitations of current 3D TSE MRI include long scan times. • 3D CAIPIRINHA SPACE allows now a fourfold-accelerated data acquisition. • 3D CAIPIRINHA SPACE enables high-spatial-resolution ankle MRI within 10 min. • 10-min 3D CAIPIRINHA SPACE produces equal-or-better quality than 20-min 2D TSE.
OBJECTIVES: To test the hypothesis that a fourfold CAIPIRINHA accelerated, 10-min, high-resolution, isotropic 3D TSE MRI prototype protocol of the ankle derives equal or better quality than a 20-min 2D TSE standard protocol. METHODS: Following internal review board approval and informed consent, 3-Tesla MRI of the ankle was obtained in 24 asymptomatic subjects including 10-min 3D CAIPIRINHA SPACE TSE prototype and 20-min 2D TSE standard protocols. Outcome variables included image quality and visibility of anatomical structures using 5-point Likert scales. Non-parametric statistical testing was used. P values ≤0.001 were considered significant. RESULTS: Edge sharpness, contrast resolution, uniformity, noise, fat suppression and magic angle effects were without statistical difference on 2D and 3D TSE images (p > 0.035). Fluid was mildly brighter on intermediate-weighted 2D images (p < 0.001), whereas 3D images had substantially less partial volume, chemical shift and no pulsatile-flow artifacts (p < 0.001). Oblique and curved planar 3D images resulted in mildly-to-substantially improved visualization of joints, spring, bifurcate, syndesmotic, collateral and sinus tarsi ligaments, and tendons (p < 0.001, respectively). CONCLUSIONS: 3D TSE MRI with CAIPIRINHA acceleration enables high-spatial resolution oblique and curved planar MRI of the ankle and visualization of ligaments, tendons and joints equally well or better than a more time-consuming anisotropic 2D TSE MRI. KEY POINTS: • High-resolution 3D TSE MRI improves visualization of ankle structures. • Limitations of current 3D TSE MRI include long scan times. • 3D CAIPIRINHA SPACE allows now a fourfold-accelerated data acquisition. • 3D CAIPIRINHA SPACE enables high-spatial-resolution ankle MRI within 10 min. • 10-min 3D CAIPIRINHA SPACE produces equal-or-better quality than 20-min 2D TSE.
Authors: Felix A Breuer; Martin Blaimer; Matthias F Mueller; Nicole Seiberlich; Robin M Heidemann; Mark A Griswold; Peter M Jakob Journal: Magn Reson Med Date: 2006-03 Impact factor: 4.668
Authors: Bernard Mengiardi; Christian W A Pfirrmann; Patrick Vienne; Juerg Hodler; Marco Zanetti Journal: Radiology Date: 2007-01-05 Impact factor: 11.105
Authors: Oliver Ristow; Lynne Steinbach; Gregory Sabo; Roland Krug; Markus Huber; Isabel Rauscher; Ben Ma; Thomas M Link Journal: Eur Radiol Date: 2009-01-10 Impact factor: 5.315
Authors: Katherine L Wright; Michael W Harrell; John A Jesberger; Luis Landeras; Dean A Nakamoto; Smitha Thomas; Dominik Nickel; Randall Kroeker; Mark A Griswold; Vikas Gulani Journal: J Magn Reson Imaging Date: 2013-10-07 Impact factor: 4.813
Authors: Mike Notohamiprodjo; Annie Horng; Bernhard Kuschel; Dominik Paul; Guobin Li; Jose G Raya; Maximilian F Reiser; Christian Glaser Journal: Eur J Radiol Date: 2012-05-12 Impact factor: 3.528
Authors: Jessica R Mann; Ged G Wieschhoff; Ryan Tai; William C Wrobel; Nehal Shah; Jacob C Mandell Journal: Skeletal Radiol Date: 2019-08-17 Impact factor: 2.199
Authors: Benjamin Fritz; Susanne Bensler; Gaurav K Thawait; Esther Raithel; Steven E Stern; Jan Fritz Journal: Eur Radiol Date: 2018-07-23 Impact factor: 5.315
Authors: Hannes Seuss; Matthias Hammon; Frank Roemer; Rafael Heiss; Rolf Janka; Michael Uder; Peter Dankerl Journal: Diagnostics (Basel) Date: 2021-01-29