The response of a spherical tissue-equivalent proportional counter to different heavy ions having similar velocities.

Phillip J Taddei1, Thomas B Borak, Stephen B Guetersloh, Brad B Gersey, Cary Zeitlin, Lawrence Heilbronn, Jack Miller, Takeshi Murakami, Yoshiyuki Iwata.   

Abstract

A tissue-equivalent proportional counter (TEPC) has been used as a dosimeter in mixed radiation fields. Since it does not measure LET directly, the response function must be characterized in order to estimate quality factor and thus equivalent dose for the incident radiation. The objectives of this study were to measure the response of a spherical TEPC for different high-energy heavy ions (HZE) having similar velocity and to determine how quality factors can be determined. Data were obtained at the HIMAC heavy ion accelerator for (4)He and (12)C at 220 +/- 5 MeV/nucleon (beta = 0.59) and (12)C, (16)O, (28)Si and (56)Fe at 376 +/- 15 MeV/nucleon (beta = 0.70). A particle spectrometer recorded the charge and position of each incident beam particle. Events with low energy deposition were observed for particles that passed through the wall of the TEPC but not through the sensitive volume. The frequency averaged lineal energy, y(f), was always less than the LET of the incident particles. The dose averaged lineal energy, y(D), was approximately equal to LET for particles with LET greater than 10 keV/mum, whereas y(D) was larger than LET for the lighter particles with lower LET. Part of this effect is due to detector resolution and energy straggling that increases the variance of the response function. Although the TEPC is not a LET spectrometer, it can provide real time measurements of dose and provide estimates of quality factors for HZE particles using averaged values of lineal energy.

Entities:  

Year:  2006        PMID: 19079798      PMCID: PMC2600531          DOI: 10.1016/j.radmeas.2006.01.003

Source DB:  PubMed          Journal:  Radiat Meas        ISSN: 1350-4487            Impact factor:   1.898


  17 in total

Review 1.  Radiation measurements in low Earth orbit: U.S. and Russian results.

Authors:  G D Badhwar
Journal:  Health Phys       Date:  2000-11       Impact factor: 1.316

2.  A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis.

Authors:  C J Zeitlin; K A Frankel; W Gong; L Heilbronn; E J Lampo; R Leres; J Miller; W Schimmerling
Journal:  Radiat Meas       Date:  1994       Impact factor: 1.898

3.  The response of tissue-equivalent proportional counters to heavy ions.

Authors:  Hooshang Nikjoo; Igor K Khvostunov; Francis A Cucinotta
Journal:  Radiat Res       Date:  2002-04       Impact factor: 2.841

4.  The use of TEPC for reference dosimetry.

Authors:  L Lindborg; J E Kyllonen; P Beck; J F Bottollier-Depois; S Gerdung; R E Grillmaier; U Schrewe
Journal:  Radiat Prot Dosimetry       Date:  1999       Impact factor: 0.972

5.  A device for the measurement of dose as a function of specific ionization.

Authors:  H H ROSSI; W ROSENZWEIG
Journal:  Radiology       Date:  1955-03       Impact factor: 11.105

6.  Comparisons of LET distributions for protons with energies between 50 and 200 MeV determined using a spherical tissue-equivalent proportional counter (TEPC) and a position-sensitive silicon spectrometer (RRMD-III).

Authors:  T B Borak; T Doke; T Fuse; S Guetersloh; L Heilbronn; K Hara; M Moyers; S Suzuki; P Taddei; K Terasawa; C J Zeitlin
Journal:  Radiat Res       Date:  2004-12       Impact factor: 2.841

7.  Wall effects observed in tissue-equivalent proportional counters from 1.05 GeV/nucleon iron-56 particles.

Authors:  S E Rademacher; T B Borak; C Zeitlin; L Heilbronn; J Miller
Journal:  Radiat Res       Date:  1998-04       Impact factor: 2.841

8.  The multiple Coulomb scattering of very heavy charged particles.

Authors:  M Wong; W Schimmerling; M H Phillips; B A Ludewigt; D A Landis; J T Walton; S B Curtis
Journal:  Med Phys       Date:  1990 Mar-Apr       Impact factor: 4.071

9.  The response of a spherical tissue-equivalent proportional counter to different ions having similar linear energy transfer.

Authors:  Stephen B Guetersloh; Thomas B Borak; Phillip J Taddei; Cary Zeitlin; Lawrence Heilbronn; Jack Miller; Takeshi Murakami; Yoshiyuki Iwata
Journal:  Radiat Res       Date:  2004-01       Impact factor: 2.841

10.  Application of TEPC microdosimetry to boron neutron capture therapy.

Authors:  J Burmeister; C Kota; R L Maughan; A J Waker; K Riley; L Wielopolski
Journal:  Radiat Prot Dosimetry       Date:  2002       Impact factor: 0.972

View more
  3 in total

1.  A comparison of the measured responses of a tissue-equivalent proportional counter to high energy heavy (HZE) particles and those simulated using the Geant4 Monte Carlo code.

Authors:  Phillip J Taddei; Zhongxiang Zhao; Thomas B Borak
Journal:  Radiat Meas       Date:  2008-10       Impact factor: 1.898

2.  Low- and middle-income countries can reduce risks of subsequent neoplasms by referring pediatric craniospinal cases to centralized proton treatment centers.

Authors:  Phillip J Taddei; Nabil Khater; Bassem Youssef; Rebecca M Howell; Wassim Jalbout; Rui Zhang; Fady B Geara; Annelise Giebeler; Anita Mahajan; Dragan Mirkovic; Wayne D Newhauser
Journal:  Biomed Phys Eng Express       Date:  2018-02-07

3.  Dual-storage phosphor proton therapy dosimetry: Simultaneous quantification of dose and linear energy transfer.

Authors:  Jufri Setianegara; Thomas R Mazur; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2021-02-19       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.