| Literature DB >> 15548122 |
T B Borak1, T Doke, T Fuse, S Guetersloh, L Heilbronn, K Hara, M Moyers, S Suzuki, P Taddei, K Terasawa, C J Zeitlin.
Abstract
Experiments have been performed to measure the response of a spherical tissue-equivalent proportional counter (TEPC) and a silicon-based LET spectrometer (RRMD-III) to protons with energies ranging from 50-200 MeV. This represents a large portion of the energy distribution for trapped protons encountered by astronauts in low-Earth orbit. The beam energies were obtained using plastic polycarbonate degraders with a monoenergetic beam that was extracted from a proton synchrotron. The LET spectrometer provided excellent agreement with the expected LET distribution emerging from the energy degraders. The TEPC cannot measure the LET distribution directly. However, the frequency mean value of lineal energy, y(-)(f), provided a good approximation to LET. This is in contrast to previous results for high-energy heavy ions where y(-)(f) underestimated LET, whereas the dose-averaged lineal energy, y(-)(D), provided a good approximation to LET.Keywords: NASA Discipline Radiation Health; Non-NASA Center
Mesh:
Substances:
Year: 2004 PMID: 15548122 DOI: 10.1667/rr3262
Source DB: PubMed Journal: Radiat Res ISSN: 0033-7587 Impact factor: 2.841