Literature DB >> 11893246

The response of tissue-equivalent proportional counters to heavy ions.

Hooshang Nikjoo1, Igor K Khvostunov, Francis A Cucinotta.   

Abstract

The paper presents a theoretical model for the response of a tissue-equivalent proportional counter (TEPC) irradiated with charged particles. Heavy ions and iron ions in particular constitute a significant part of radiation in space. TEPCs are used for all space shuttle and International Space Station (ISS) missions to estimate the dose and radiation quality (in terms of lineal energy) inside spacecraft. The response of the tissue-equivalent proportional counters shows distortions at the wall/cavity interface. In this paper, we present microdosimetric investigation using Monte Carlo track structure calculations to simulate the response of a TEPC to charged particles of various LET (1 MeV protons, 2.4 MeV alpha particles, 46 MeV/nucleon 20Ne, 55 MeV/nucleon 20Ne, 45 MeV/nucleon 40Ar, and 1.05 GeV/nucleon 56Fe). Data are presented for energy lost and energy absorbed in the counter cavity and wall. The model calculations are in good agreement with the results of Rademacher et al. (Radiat. Res. 149, 387-389, 1998), including the study of the interface between the wall and the sensitive region of the counter. It is shown that the anomalous response observed at large event sizes in the experiment is due to an enhanced entry of secondary electrons from the wall into the gas cavity.

Entities:  

Keywords:  NASA Center JSC; NASA Discipline Radiation Health

Mesh:

Substances:

Year:  2002        PMID: 11893246     DOI: 10.1667/0033-7587(2002)157[0435:trotep]2.0.co;2

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  3 in total

1.  The response of a spherical tissue-equivalent proportional counter to different heavy ions having similar velocities.

Authors:  Phillip J Taddei; Thomas B Borak; Stephen B Guetersloh; Brad B Gersey; Cary Zeitlin; Lawrence Heilbronn; Jack Miller; Takeshi Murakami; Yoshiyuki Iwata
Journal:  Radiat Meas       Date:  2006-10       Impact factor: 1.898

Review 2.  Proton relative biological effectiveness (RBE): a multiscale problem.

Authors:  Tracy Sa Underwood; Stephen J McMahon
Journal:  Br J Radiol       Date:  2018-07-26       Impact factor: 3.039

3.  A comparison of the measured responses of a tissue-equivalent proportional counter to high energy heavy (HZE) particles and those simulated using the Geant4 Monte Carlo code.

Authors:  Phillip J Taddei; Zhongxiang Zhao; Thomas B Borak
Journal:  Radiat Meas       Date:  2008-10       Impact factor: 1.898

  3 in total