Literature DB >> 18383281

Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels.

K Setsompop1, L L Wald, V Alagappan, B A Gagoski, E Adalsteinsson.   

Abstract

Spatially tailored radio frequency (RF) excitations accelerated with parallel transmit systems provide the opportunity to create shaped volume excitations or mitigate inhomogeneous B(1) excitation profiles with clinically relevant pulse lengths. While such excitations are often designed as a least-squares optimized approximation to a target magnitude and phase profile, adherence to the target phase profile is usually not important as long as the excitation phase is slowly varying compared with the voxel dimension. In this work, we demonstrate a method for a magnitude least squares optimization of the target magnetization profile for multichannel parallel excitation to improve the magnitude profile and reduce the RF power at the cost of a less uniform phase profile. The method enables the designer to trade off the allowed spatial phase variation for the improvement in magnitude profile and reduction in RF power. We validate the method with simulation studies and demonstrate its performance in fourfold accelerated two-dimensional spiral excitations, as well as for uniform in-plane slice selective parallel excitations using an eight-channel transmit array on a 7T human MRI scanner. The experimental results are in good agreement with the simulations, which show significant improvement in the magnitude profile and reductions in the required RF power while still maintaining negligible intravoxel phase variation.

Entities:  

Mesh:

Year:  2008        PMID: 18383281      PMCID: PMC2715966          DOI: 10.1002/mrm.21513

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Dualband spectral-spatial RF pulses for prostate MR spectroscopic imaging.

Authors:  A A Schricker; J M Pauly; J Kurhanewicz; M G Swanson; D B Vigneron
Journal:  Magn Reson Med       Date:  2001-12       Impact factor: 4.668

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies.

Authors:  Christopher M Collins; Wanzhan Liu; Bryan J Swift; Michael B Smith
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

4.  Improved gradient-echo 3D magnetic resonance imaging using pseudo-echoes created by frequency-swept pulses.

Authors:  Jang-Yeon Park; Lance DelaBarre; Michael Garwood
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

5.  Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Authors:  William Grissom; Chun-yu Yip; Zhenghui Zhang; V Andrew Stenger; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

6.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

7.  Parallel RF transmission with eight channels at 3 Tesla.

Authors:  Kawin Setsompop; Lawrence L Wald; Vijayanand Alagappan; Borjan Gagoski; Franz Hebrank; Ulrich Fontius; Franz Schmitt; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

8.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

9.  Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity.

Authors:  Suwit Saekho; Chun-yu Yip; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

10.  Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging.

Authors:  P Le Roux; R J Gilles; G C McKinnon; P G Carlier
Journal:  J Magn Reson Imaging       Date:  1998 Sep-Oct       Impact factor: 4.813

View more
  72 in total

1.  Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array.

Authors:  Kamil Uğurbil; Edward Auerbach; Steen Moeller; Andrea Grant; Xiaoping Wu; Pierre-Francois Van de Moortele; Cheryl Olman; Lance DelaBarre; Scott Schillak; Jerahmie Radder; Russell Lagore; Gregor Adriany
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

2.  Broadband slab selection with B1+ mitigation at 7T via parallel spectral-spatial excitation.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Andreas Potthast; Franz Hebrank; Ulrich Fontius; Franz Schmitt; L L Wald; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

3.  Pushing the limits of in vivo diffusion MRI for the Human Connectome Project.

Authors:  K Setsompop; R Kimmlingen; E Eberlein; T Witzel; J Cohen-Adad; J A McNab; B Keil; M D Tisdall; P Hoecht; P Dietz; S F Cauley; V Tountcheva; V Matschl; V H Lenz; K Heberlein; A Potthast; H Thein; J Van Horn; A Toga; F Schmitt; D Lehne; B R Rosen; V Wedeen; L L Wald
Journal:  Neuroimage       Date:  2013-05-24       Impact factor: 6.556

4.  Strategies for improved 3D small-tip fast recovery imaging.

Authors:  Hao Sun; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2013-10-11       Impact factor: 4.668

5.  Comparison of simulated parallel transmit body arrays at 3 T using excitation uniformity, global SAR, local SAR, and power efficiency metrics.

Authors:  Bastien Guérin; Matthias Gebhardt; Peter Serano; Elfar Adalsteinsson; Michael Hamm; Josef Pfeuffer; Juergen Nistler; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

6.  Controlling radiofrequency-induced currents in guidewires using parallel transmit.

Authors:  Maryam Etezadi-Amoli; Pascal Stang; Adam Kerr; John Pauly; Greig Scott
Journal:  Magn Reson Med       Date:  2014-12-17       Impact factor: 4.668

7.  Mitigation of B1+ inhomogeneity using spatially selective excitation with jointly designed quadratic spatial encoding magnetic fields and RF shimming.

Authors:  Yi-Cheng Hsu; Riccardo Lattanzi; Ying-Hua Chu; Martijn A Cloos; Daniel K Sodickson; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2016-10-02       Impact factor: 4.668

8.  Joint design of large-tip-angle parallel RF pulses and blipped gradient trajectories.

Authors:  Zhipeng Cao; Manus J Donahue; Jun Ma; William A Grissom
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668

9.  Design of parallel transmission pulses for simultaneous multislice with explicit control for peak power and local specific absorption rate.

Authors:  Bastien Guérin; Kawin Setsompop; Huihui Ye; Benedikt A Poser; Andrew V Stenger; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-06-17       Impact factor: 4.668

10.  Fast large-tip-angle multidimensional and parallel RF pulse design in MRI.

Authors:  William A Grissom; Dan Xu; Adam B Kerr; Jeffrey A Fessler; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.