Literature DB >> 19000872

Validation and statistical power comparison of methods for analyzing free-response observer performance studies.

Dev P Chakraborty1.   

Abstract

RATIONALE AND
OBJECTIVES: The aim of this work was to validate and compare the statistical powers of proposed methods for analyzing free-response data using a search-model-based simulator.
MATERIALS AND METHODS: A free-response data simulator is described that can model a single reader interpreting the same cases in two modalities, or two computer-aided detection (CAD) algorithms, or two human observers, interpreting the same cases in one modality. A variance components model, analogous to the Roe and Metz receiver-operating characteristic (ROC) data simulator, is described; it models intracase and intermodality correlations in free-response studies. Two generic observers were simulated: a quasi-human observer and a quasi-CAD algorithm. Null hypothesis (NH) validity and statistical powers of ROC, jackknife alternative free-response operating characteristic (JAFROC), a variant of JAFROC termed JAFROC-1, initial detection and candidate analysis (IDCA), and a nonparametric (NP) approach were investigated.
RESULTS: All methods had valid NH behavior over a wide range of simulator parameters. For equal numbers of normal and abnormal cases, for the human observer, the statistical power ranking of the methods was JAFROC-1 > JAFROC > (IDCA approximately NP) > ROC. For the CAD algorithm, the ranking was (NP approximately IDCA) > (JAFROC-1 approximately JAFROC) > ROC. In either case, the statistical power of the highest ranked method exceeded that of the lowest ranked method by about a factor of two. Dependence of statistical power on simulator parameters followed expected trends. For data sets with more abnormal cases than normal cases, JAFROC-1 power significantly exceeded JAFROC power.
CONCLUSION: Based on this work, the recommendation is to use JAFROC-1 for human observers (including human observers with CAD assist) and the NP method for evaluating CAD algorithms.

Entities:  

Mesh:

Year:  2008        PMID: 19000872      PMCID: PMC2705988          DOI: 10.1016/j.acra.2008.07.018

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  22 in total

1.  A contaminated binormal model for ROC data: Part III. Initial evaluation with detection ROC data.

Authors:  D D Dorfman; K S Berbaum
Journal:  Acad Radiol       Date:  2000-06       Impact factor: 3.173

2.  Observer studies involving detection and localization: modeling, analysis, and validation.

Authors:  Dev P Chakraborty; Kevin S Berbaum
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

3.  ROC curves predicted by a model of visual search.

Authors:  D P Chakraborty
Journal:  Phys Med Biol       Date:  2006-07-06       Impact factor: 3.609

Review 4.  Receiver operating characteristic analysis: a tool for the quantitative evaluation of observer performance and imaging systems.

Authors:  Charles E Metz
Journal:  J Am Coll Radiol       Date:  2006-06       Impact factor: 5.532

5.  Variance-component modeling in the analysis of receiver operating characteristic index estimates.

Authors:  C A Roe; C E Metz
Journal:  Acad Radiol       Date:  1997-08       Impact factor: 3.173

6.  Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: validation with computer simulation.

Authors:  C A Roe; C E Metz
Journal:  Acad Radiol       Date:  1997-04       Impact factor: 3.173

7.  Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data.

Authors:  D P Chakraborty
Journal:  Med Phys       Date:  1989 Jul-Aug       Impact factor: 4.071

8.  A visual concept shapes image perception.

Authors:  H L Kundel; C F Nodine
Journal:  Radiology       Date:  1983-02       Impact factor: 11.105

9.  Reliable and computationally efficient maximum-likelihood estimation of "proper" binormal ROC curves.

Authors:  Lorenzo L Pesce; Charles E Metz
Journal:  Acad Radiol       Date:  2007-07       Impact factor: 3.173

10.  Evaluating computer-aided detection algorithms.

Authors:  Hong Jun Yoon; Bin Zheng; Berkman Sahiner; Dev P Chakraborty
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

View more
  37 in total

1.  Digital breast tomosynthesis: computer-aided detection of clustered microcalcifications on planar projection images.

Authors:  Ravi K Samala; Heang-Ping Chan; Yao Lu; Lubomir M Hadjiiski; Jun Wei; Mark A Helvie
Journal:  Phys Med Biol       Date:  2014-11-13       Impact factor: 3.609

2.  Measures of angular spread and entropy for the detection of architectural distortion in prior mammograms.

Authors:  Shantanu Banik; Rangaraj M Rangayyan; J E Leo Desautels
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-03-30       Impact factor: 2.924

3.  Evaluating imaging and computer-aided detection and diagnosis devices at the FDA.

Authors:  Brandon D Gallas; Heang-Ping Chan; Carl J D'Orsi; Lori E Dodd; Maryellen L Giger; David Gur; Elizabeth A Krupinski; Charles E Metz; Kyle J Myers; Nancy A Obuchowski; Berkman Sahiner; Alicia Y Toledano; Margarita L Zuley
Journal:  Acad Radiol       Date:  2012-02-03       Impact factor: 3.173

4.  Radiological technologists' performance for the detection of malignant microcalcifications in digital mammograms without and with a computer-aided detection system.

Authors:  Rie Tanaka; Miho Takamori; Yoshikazu Uchiyama; Junji Shiraishi
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-27

5.  Distributed human intelligence for colonic polyp classification in computer-aided detection for CT colonography.

Authors:  Tan B Nguyen; Shijun Wang; Vishal Anugu; Natalie Rose; Matthew McKenna; Nicholas Petrick; Joseph E Burns; Ronald M Summers
Journal:  Radiology       Date:  2012-01-24       Impact factor: 11.105

6.  ROCView: prototype software for data collection in jackknife alternative free-response receiver operating characteristic analysis.

Authors:  J Thompson; P Hogg; S Thompson; D Manning; K Szczepura
Journal:  Br J Radiol       Date:  2012-05-09       Impact factor: 3.039

7.  Quantifying the clinical relevance of a laboratory observer performance paradigm.

Authors:  D P Chakraborty; T M Haygood; J Ryan; E M Marom; M Evanoff; M F McEntee; P C Brennan
Journal:  Br J Radiol       Date:  2012-05-09       Impact factor: 3.039

Review 8.  A brief history of free-response receiver operating characteristic paradigm data analysis.

Authors:  Dev P Chakraborty
Journal:  Acad Radiol       Date:  2013-04-12       Impact factor: 3.173

9.  A status report on free-response analysis.

Authors:  D P Chakraborty
Journal:  Radiat Prot Dosimetry       Date:  2010-01-18       Impact factor: 0.972

10.  Evaluation of Transient Motion During Gadoxetic Acid-Enhanced Multiphasic Liver Magnetic Resonance Imaging Using Free-Breathing Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging.

Authors:  Jeong Hee Yoon; Jeong Min Lee; Mi Hye Yu; Bo Yun Hur; Robert Grimm; Kai Tobias Block; Hersh Chandarana; Berthold Kiefer; Yohan Son
Journal:  Invest Radiol       Date:  2018-01       Impact factor: 6.016

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.