Literature DB >> 15377098

Observer studies involving detection and localization: modeling, analysis, and validation.

Dev P Chakraborty1, Kevin S Berbaum.   

Abstract

Although the receiver operating characteristic (ROC) paradigm is the accepted method for evaluation of diagnostic imaging systems, it has some serious shortcomings inasmuch as it is restricted to one observer report per image. By contrast the free-response ROC (FROC) paradigm and associated analysis method allows the observer to report multiple abnormalities within each imaging study, and uses the location of reported abnormalities to improve the measurement. Because the ROC method cannot accommodate multiple responses or use location information, its statistical power will suffer. The FROC paradigm/analysis has not enjoyed widespread acceptance because of concern about whether responses made to the same diagnostic study can be treated as independent. We propose a new jackknife FROC analysis method (JAFROC) that does not make the independence assumption. The new analysis method combines elements of FROC and the Dorfman-Berbaum-Metz (DBM) methods. To compare JAFROC to an earlier free-response analysis method (specifically the alternative free-response, or AFROC method), and to the DBM method, which uses conventional ROC scoring, we developed a model for generating simulated FROC data. The simulation model is based on an eye-movement model of how experts evaluate images. It allowed us to examine null hypothesis (NH) behavior and statistical power of the different methods. We found that AFROC analysis did not pass the NH test, being unduly conservative. Both the JAFROC method and the DBM method passed the NH test, but JAFROC had more statistical power than the DBM method. The results of this comparison suggest that future studies of diagnostic performance may enjoy improved statistical power or reduced sample size requirements through the use of the JAFROC method.

Entities:  

Mesh:

Year:  2004        PMID: 15377098     DOI: 10.1118/1.1769352

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  122 in total

1.  Detection of noncalcified pulmonary nodules on low-dose MDCT: comparison of the sensitivity of two CAD systems by using a double reference standard.

Authors:  A R Larici; M Amato; P Ordóñez; F Maggi; L Menchini; A Caulo; L Calandriello; G Vallati; S Giunta; M Crecco; L Bonomo
Journal:  Radiol Med       Date:  2012-02-10       Impact factor: 3.469

2.  Basic concepts and development of an all-purpose computer interface for ROC/FROC observer study.

Authors:  Junji Shiraishi; Daisuke Fukuoka; Takeshi Hara; Hiroyuki Abe
Journal:  Radiol Phys Technol       Date:  2012-07-05

Review 3.  ROC analysis in medical imaging: a tutorial review of the literature.

Authors:  Charles E Metz
Journal:  Radiol Phys Technol       Date:  2007-10-27

4.  Evaluating imaging and computer-aided detection and diagnosis devices at the FDA.

Authors:  Brandon D Gallas; Heang-Ping Chan; Carl J D'Orsi; Lori E Dodd; Maryellen L Giger; David Gur; Elizabeth A Krupinski; Charles E Metz; Kyle J Myers; Nancy A Obuchowski; Berkman Sahiner; Alicia Y Toledano; Margarita L Zuley
Journal:  Acad Radiol       Date:  2012-02-03       Impact factor: 3.173

5.  Reporting instructions significantly impact false positive rates when reading chest radiographs.

Authors:  John W Robinson; Patrick C Brennan; Claudia Mello-Thoms; Sarah J Lewis
Journal:  Eur Radiol       Date:  2016-01-15       Impact factor: 5.315

6.  Radiological technologists' performance for the detection of malignant microcalcifications in digital mammograms without and with a computer-aided detection system.

Authors:  Rie Tanaka; Miho Takamori; Yoshikazu Uchiyama; Junji Shiraishi
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-27

7.  Observer performance for adaptive, image-based denoising and filtered back projection compared to scanner-based iterative reconstruction for lower dose CT enterography.

Authors:  Joel G Fletcher; Amy K Hara; Jeff L Fidler; Alvin C Silva; John M Barlow; Rickey E Carter; Adam Bartley; Maria Shiung; David R Holmes; Nicolas K Weber; David H Bruining; Lifeng Yu; Cynthia H McCollough
Journal:  Abdom Imaging       Date:  2015-06

8.  Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.

Authors:  D Kim; Y J Heo; H W Jeong; J W Baek; J-Y Han; J Y Lee; S-C Jin; H J Baek
Journal:  AJNR Am J Neuroradiol       Date:  2019-08-01       Impact factor: 3.825

9.  Morphologic blooming in breast MRI as a characterization of margin for discriminating benign from malignant lesions.

Authors:  Alan Penn; Scott Thompson; Rachel Brem; Constance Lehman; Paul Weatherall; Mitchell Schnall; Gillian Newstead; Emily Conant; Susan Ascher; Elizabeth Morris; Etta Pisano
Journal:  Acad Radiol       Date:  2006-11       Impact factor: 3.173

Review 10.  A brief history of free-response receiver operating characteristic paradigm data analysis.

Authors:  Dev P Chakraborty
Journal:  Acad Radiol       Date:  2013-04-12       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.