Literature DB >> 18946513

Investigation of new flow modifying endovascular image-guided interventional (EIGI) techniques in patient-specific aneurysm phantoms (PSAPs) using optical imaging.

Jr Sherman1, Hs Rangwala, Cn Ionita, Ac Dohatcu, Jw Lee, Dr Bednarek, Kr Hoffmann, S Rudin.   

Abstract

Effective minimally invasive treatment of cerebral bifurcation aneurysms is challenging due to the complex and remote vessel morphology. An evaluation of endovascular treatment in a phantom involving image-guided deployment of new asymmetric stents consisting of polyurethane patches placed to modify blood flow into the aneurysm is reported. The 3D lumen-geometry of a patient-specific basilar-artery bifurcation aneurysm was derived from a segmented computed-tomography dataset. This was used in a stereolithographic rapid-prototyping process to generate a mold which was then used to create any number of exact wax models. These models in turn were used in a lost-wax technique to create transparent elastomer patient-specific aneurysm phantoms (PSAP) for evaluating the effectiveness of asymmetric-stent deployment for flow modification. Flow was studied by recording real-time digitized video images of optical dye in the PSAP and its feeding vessel. For two asymmetric stent placements: through the basilar into the right-posterior communicating artery (RPCA) and through the basilar into the left-posterior communicating artery (LPCA), the greatest deviation of flow streamlines away from the aneurysm occurred for the RPCA stent deployment. Flow was also substantially affected by variations of inflow angle into the basilar artery, resulting in alternations in washout times as derived from time-density curves. Evaluation of flow in the PSAPs with real-time optical imaging can be used to determine new EIGI effectiveness and to validate computational-fluid-dynamic calculations for EIGI-treatment planning.

Entities:  

Year:  2008        PMID: 18946513      PMCID: PMC2570532          DOI: 10.1117/12.772583

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  10 in total

Review 1.  Fluid mechanics of vascular systems, diseases, and thrombosis.

Authors:  D M Wootton; D N Ku
Journal:  Annu Rev Biomed Eng       Date:  1999       Impact factor: 9.590

2.  Determination of instantaneous and average blood flow rates from digital angiograms of vessel phantoms using distance-density curves.

Authors:  K R Hoffmann; K Doi; L E Fencil
Journal:  Invest Radiol       Date:  1991-03       Impact factor: 6.016

3.  Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT).

Authors:  C N Ionita; C Keleshis; V Patel; G Yadava; K R Hoffmann; D R Bednarek; A Jain; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

4.  LabVIEW Graphical User Interface for a New High Sensitivity, High Resolution Micro-Angio-Fluoroscopic and ROI-CBCT System.

Authors:  C Keleshis; Cn Ionita; G Yadava; V Patel; Dr Bednarek; Kr Hoffmann; A Verevkin; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

5.  Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity.

Authors:  B B Lieber; A P Stancampiano; A K Wakhloo
Journal:  Ann Biomed Eng       Date:  1997 May-Jun       Impact factor: 3.934

6.  Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coils.

Authors:  G Bavinzski; V Talazoglu; M Killer; B Richling; A Gruber; C E Gross; H Plenk
Journal:  J Neurosurg       Date:  1999-08       Impact factor: 5.115

7.  Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using a computerized tomography angiogram as a mold.

Authors:  S Tateshima; Y Murayama; J P Villablanca; T Morino; H Takahashi; T Yamauchi; K Tanishita; F Vinuela
Journal:  J Neurosurg       Date:  2001-12       Impact factor: 5.115

8.  Finite-element modeling of the hemodynamics of stented aneurysms.

Authors:  Gordon R Stuhne; David A Steinman
Journal:  J Biomech Eng       Date:  2004-06       Impact factor: 2.097

9.  Measurement of flow modification in phantom aneurysm model: comparison of coils and a longitudinally and axially asymmetric stent--initial findings.

Authors:  Stephen Rudin; Zhou Wang; Iacovos Kyprianou; Kenneth R Hoffmann; Ye Wu; Hui Meng; Lee R Guterman; Balazs Nemes; Daniel R Bednarek; Jacek Dmochowski; L Nelson Hopkins
Journal:  Radiology       Date:  2004-04       Impact factor: 11.105

10.  Double-stent method: therapeutic alternative for small wide-necked aneurysms. Technical note.

Authors:  Arnd Doerfler; Isabel Wanke; Thomas Egelhof; Dietmar Stolke; Michael Forsting
Journal:  J Neurosurg       Date:  2004-01       Impact factor: 5.115

  10 in total
  10 in total

1.  Investigation of metrics to assess vascular flow modifications for diverter device designs using hydrodynamics and angiographic studies.

Authors:  Ciprian N Ionita; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-23

2.  Design Optimization for Accurate Flow Simulations in 3D Printed Vascular Phantoms Derived from Computed Tomography Angiography.

Authors:  Kelsey Sommer; Richard L Izzo; Lauren Shepard; Alexander R Podgorsak; Stephen Rudin; Adnan H Siddiqui; Michael F Wilson; Erin Angel; Zaid Said; Michael Springer; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

3.  Angiographic imaging evaluation of patient-specific bifurcation-aneurysm phantom treatment with pre-shaped, self-expanding, flow-diverting stents: feasibility study.

Authors:  Ciprian N Ionita; Himanshu Suri; Sabareesh Nataranjian; Adnan Siddiqui; Elad Levy; Nelson L Hopkins; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011

4.  Evaluation of challenges and limitations of mechanical thrombectomy using 3D printed neurovascular phantoms.

Authors:  Kelsey N Sommer; Mohammad Mahdi Shiraz Bhurwani; Maxim Mokin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

5.  Endovascular image-guided interventions (EIGIs).

Authors:  Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

6.  Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

Authors:  Ciprian N Ionita; Andreea Dohatcu; Andrey Sinelnikov; Jason Sherman; Christos Keleshis; Ann M Paciorek; K R Hoffmann; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

7.  Treatment Planning for Image-Guided Neuro-Vascular Interventions Using Patient-Specific 3D Printed Phantoms.

Authors:  M Russ; R O'Hara; S V Setlur Nagesh; M Mokin; C Jimenez; A Siddiqui; D Bednarek; S Rudin; C Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-19

8.  The asymmetric vascular stent: efficacy in a rabbit aneurysm model.

Authors:  Ciprian N Ionita; Ann M Paciorek; Andreea Dohatcu; Kenneth R Hoffmann; Daniel R Bednarek; John Kolega; Elad I Levy; L Nelson Hopkins; Stephen Rudin; J Duffy Mocco
Journal:  Stroke       Date:  2009-01-08       Impact factor: 7.914

9.  Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing.

Authors:  Ciprian N Ionita; Maxim Mokin; Nicole Varble; Daniel R Bednarek; Jianping Xiang; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-13

10.  Partially polyurethane-covered stent for cerebral aneurysm treatment.

Authors:  Hussain S Rangwala; Ciprian N Ionita; Stephen Rudin; Robert E Baier
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-05       Impact factor: 3.405

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.