Literature DB >> 26778878

Treatment Planning for Image-Guided Neuro-Vascular Interventions Using Patient-Specific 3D Printed Phantoms.

M Russ1, R O'Hara1, S V Setlur Nagesh1, M Mokin1, C Jimenez2, A Siddiqui1, D Bednarek1, S Rudin1, C Ionita1.   

Abstract

Minimally invasive endovascular image-guided interventions (EIGIs) are the preferred procedures for treatment of a wide range of vascular disorders. Despite benefits including reduced trauma and recovery time, EIGIs have their own challenges. Remote catheter actuation and challenging anatomical morphology may lead to erroneous endovascular device selections, delays or even complications such as vessel injury. EIGI planning using 3D phantoms would allow interventionists to become familiarized with the patient vessel anatomy by first performing the planned treatment on a phantom under standard operating protocols. In this study the optimal workflow to obtain such phantoms from 3D data for interventionist to practice on prior to an actual procedure was investigated. Patient-specific phantoms and phantoms presenting a wide range of challenging geometries were created. Computed Tomographic Angiography (CTA) data was uploaded into a Vitrea 3D station which allows segmentation and resulting stereo-lithographic files to be exported. The files were uploaded using processing software where preloaded vessel structures were included to create a closed-flow vasculature having structural support. The final file was printed, cleaned, connected to a flow loop and placed in an angiographic room for EIGI practice. Various Circle of Willis and cardiac arterial geometries were used. The phantoms were tested for ischemic stroke treatment, distal catheter navigation, aneurysm stenting and cardiac imaging under angiographic guidance. This method should allow for adjustments to treatment plans to be made before the patient is actually in the procedure room and enabling reduced risk of peri-operative complications or delays.

Entities:  

Keywords:  3D Printing; Additive Manufacturing; DSA; Image Guided Interventions; Neuro-vascular; Patient-Specific Phantoms; Treatment Planning; Vascular Phantoms

Year:  2015        PMID: 26778878      PMCID: PMC4712717          DOI: 10.1117/12.2081997

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  25 in total

1.  Pipeline flow-diverter stent for endovascular treatment of intracranial aneurysms: preliminary experience in 20 patients with 27 aneurysms.

Authors:  Boris Lubicz; Laurent Collignon; Gaï Raphaeli; Olivier De Witte
Journal:  World Neurosurg       Date:  2011 Jul-Aug       Impact factor: 2.104

2.  Comparison of modern stroke thrombectomy approaches using an in vitro cerebrovascular occlusion model.

Authors:  M Mokin; S V Setlur Nagesh; C N Ionita; E I Levy; A H Siddiqui
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-06       Impact factor: 3.825

3.  Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents.

Authors:  Ciprian N Ionita; Y Hoi; H Meng; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004

4.  Angiographic imaging evaluation of patient-specific bifurcation-aneurysm phantom treatment with pre-shaped, self-expanding, flow-diverting stents: feasibility study.

Authors:  Ciprian N Ionita; Himanshu Suri; Sabareesh Nataranjian; Adnan Siddiqui; Elad Levy; Nelson L Hopkins; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011

5.  Anesthesia and perioperative management of patients undergoing transcatheter aortic valve implantation: analysis of 90 consecutive patients with focus on perioperative complications.

Authors:  Pierre-Grégoire Guinot; Jean-Pol Depoix; Laure Etchegoyen; Abdel Benbara; Sophie Provenchère; Marie-Pierre Dilly; Ivan Philip; Daniel Enguerand; Hassan Ibrahim; Alec Vahanian; Dominique Himbert; Nawaar Al-Attar; Patrick Nataf; Jean-Marie Desmonts; Philippe Montravers; Dan Longrois
Journal:  J Cardiothorac Vasc Anesth       Date:  2010-02-25       Impact factor: 2.628

6.  Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison.

Authors:  Maxim Mokin; Ciprian N Ionita; Swetadri Vasan Setlur Nagesh; Stephen Rudin; Elad I Levy; Adnan H Siddiqui
Journal:  J Neurointerv Surg       Date:  2014-04-30       Impact factor: 5.836

7.  US multicenter experience with the wingspan stent system for the treatment of intracranial atheromatous disease: periprocedural results.

Authors:  David Fiorella; Elad I Levy; Aquilla S Turk; Felipe C Albuquerque; David B Niemann; Beverly Aagaard-Kienitz; Ricardo A Hanel; Henry Woo; Peter A Rasmussen; L Nelson Hopkins; Thomas J Masaryk; Cameron G McDougall
Journal:  Stroke       Date:  2007-02-08       Impact factor: 7.914

8.  Management of neuroform stent dislodgement and misplacement.

Authors:  L Paul Broadbent; Christopher J Moran; DeWitte T Cross; Colin P Derdeyn
Journal:  AJNR Am J Neuroradiol       Date:  2003-10       Impact factor: 3.825

9.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

10.  Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing.

Authors:  Ciprian N Ionita; Maxim Mokin; Nicole Varble; Daniel R Bednarek; Jianping Xiang; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-13
View more
  22 in total

1.  3D Printed Abdominal Aortic Aneurysm Phantom for Image Guided Surgical Planning with a Patient Specific Fenestrated Endovascular Graft System.

Authors:  Karen M Meess; Richard L Izzo; Maciej L Dryjski; Richard E Curl; Linda M Harris; Michael Springer; Adnan H Siddiqui; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

2.  3D Printed Cardiac Phantom for Procedural Planning of a Transcatheter Native Mitral Valve Replacement.

Authors:  Richard L Izzo; Ryan P O'Hara; Vijay Iyer; Rose Hansen; Karen M Meess; S V Setlur Nagesh; Stephen Rudin; Adnan H Siddiqui; Michael Springer; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-04-05

3.  A simulation platform using 3D printed neurovascular phantoms for clinical utility evaluation of new imaging technologies.

Authors:  S V Setlur Nagesh; J Hinaman; K Sommer; Z Xiong; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-12

4.  Flow-Pattern Details in an Aneurysm Model Using High-Speed 1000-Frames-per-Second Angiography.

Authors:  J M Krebs; A Shankar; S V Setlur Nagesh; J M Davies; K V Snyder; E I Levy; L N Hopkins; M Mokin; D R Bednarek; A H Siddiqui; S Rudin
Journal:  AJNR Am J Neuroradiol       Date:  2019-06-06       Impact factor: 3.825

5.  Design Optimization for Accurate Flow Simulations in 3D Printed Vascular Phantoms Derived from Computed Tomography Angiography.

Authors:  Kelsey Sommer; Richard L Izzo; Lauren Shepard; Alexander R Podgorsak; Stephen Rudin; Adnan H Siddiqui; Michael F Wilson; Erin Angel; Zaid Said; Michael Springer; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

6.  Initial evaluation of three-dimensionally printed patient-specific coronary phantoms for CT-FFR software validation.

Authors:  Lauren M Shepard; Kelsey N Sommer; Erin Angel; Vijay Iyer; Michael F Wilson; Frank J Rybicki; Dimitrios Mitsouras; Sabee Molloi; Ciprian N Ionita
Journal:  J Med Imaging (Bellingham)       Date:  2019-03-12

7.  A Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study.

Authors:  A Sonig; S V Setlur Nagesh; V S Fennell; S Gandhi; L Rangel-Castilla; C N Ionita; K V Snyder; L N Hopkins; D R Bednarek; S Rudin; A H Siddiqui; E I Levy
Journal:  AJNR Am J Neuroradiol       Date:  2018-02-15       Impact factor: 3.825

8.  Three-dimensional printing of MRI-visible phantoms and MR image-guided therapy simulation.

Authors:  Dimitris Mitsouras; Thomas C Lee; Peter Liacouras; Ciprian N Ionita; Todd Pietilla; Stephan E Maier; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2016-02-11       Impact factor: 4.668

9.  Evaluation of challenges and limitations of mechanical thrombectomy using 3D printed neurovascular phantoms.

Authors:  Kelsey N Sommer; Mohammad Mahdi Shiraz Bhurwani; Maxim Mokin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

Review 10.  Cardiac 3D Printing and its Future Directions.

Authors:  Marija Vukicevic; Bobak Mosadegh; James K Min; Stephen H Little
Journal:  JACC Cardiovasc Imaging       Date:  2017-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.