Literature DB >> 18929275

Influence of common orthodontic appliances on the diagnostic quality of cranial magnetic resonance images.

J Matthew Elison1, V Leroy Leggitt, Matthew Thomson, Udo Oyoyo, N Dan Wycliffe.   

Abstract

INTRODUCTION: The aim of this study was to evaluate cranial magnetic resonance (MR) image distortion caused by various orthodontic brackets.
METHODS: Ten subjects received 5 consecutive cranial MR scans. A control scan was conducted with Essix trays (GAC International, Bohemia, NY) fitted over the maxillary and mandibular teeth. Four experimental MR scans of the head were conducted with plastic, ceramic, titanium, and stainless steel brackets incorporated into the Essix tray material. Each MR scan consisted of 4 sequences: sagittal T1-weighted spin echo (T1 sagittal), axial T2-weighted spin echo (T2 axial), gradient echo, and diffusion-weighted imaging. Three board-certified neuroradiologists examined the MR images for distortion in predetermined regions of the head.
RESULTS: The paired Wilcoxon signed rank test showed a statistically significant difference between the mean distortion scores of stainless steel brackets and the mean distortion scores of the other experimental MR scans (P <0.0001). Interrater and intrarater agreement was high (kappa statistic and associated 95% confidence intervals).
CONCLUSIONS: The study showed that plastic, ceramic, and titanium brackets cause minimal distortion of cranial MR images (similar to the control). On the other hand, stainless steel brackets cause significant distortion, rendering several cranial regions nondiagnostic. Areas with the most distortion were the body of the mandible, the hard palate, the base of the tongue, the globes, the nasopharynx, and the frontal lobes. In general, the closer the stainless steel appliance was to a specific anatomic region, the greater the distortion of the MR image.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18929275     DOI: 10.1016/j.ajodo.2006.10.038

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  21 in total

1.  Induced magnetic moment in stainless steel components of orthodontic appliances in 1.5 T MRI scanners.

Authors:  Zhiyue J Wang; Nancy K Rollins; Hui Liang; Yong Jong Park
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

2.  Predictability of magnetic susceptibility artifacts from metallic orthodontic appliances in magnetic resonance imaging.

Authors:  F Blankenstein; B T Truong; A Thomas; N Thieme; C Zachriat
Journal:  J Orofac Orthop       Date:  2014-11-26       Impact factor: 1.938

3.  MRI with intraoral orthodontic appliance-a comparative in vitro and in vivo study of image artefacts at 1.5 T.

Authors:  C Zachriat; P Asbach; K I Blankenstein; I Peroz; F H Blankenstein
Journal:  Dentomaxillofac Radiol       Date:  2015-03-03       Impact factor: 2.419

4.  [Metal objects of the head and neck region in magnetic resonance imaging : Survey among radiologists].

Authors:  Ulrike Kielburg; Felix H Blankenstein
Journal:  Radiologe       Date:  2019-10       Impact factor: 0.635

5.  MRI safety: MRI and fixed orthodontic appliances.

Authors:  G Stonier; P Hardee
Journal:  Br Dent J       Date:  2018-10-26       Impact factor: 1.626

6.  Ceramic brackets and low friction : A possible synergy in patients requiring multiple MRI scanning.

Authors:  Matteo Camporesi; Mariana Bulhoes Galvão; André Tortamano; Gladys Cristina Dominguez; Nicolò Defraia; Efisio Defraia; Lorenzo Franchi
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

7.  Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging.

Authors:  Felix H Blankenstein; Patrick Asbach; Florian Beuer; Johannes Glienke; Stefan Mayer; Christine Zachriat
Journal:  Clin Oral Investig       Date:  2016-03-17       Impact factor: 3.573

Review 8.  Should the orthodontic brackets always be removed prior to magnetic resonance imaging (MRI)?

Authors:  Arash Poorsattar-Bejeh Mir; Manouchehr Rahmati-Kamel
Journal:  J Oral Biol Craniofac Res       Date:  2015-09-15

9.  Effect of orthodontic brackets and different wires on radiofrequency heating and magnetic field interactions during 3-T MRI.

Authors:  S Görgülü; S Ayyildiz; K Kamburoglu; S Gökçe; T Ozen
Journal:  Dentomaxillofac Radiol       Date:  2013-11-20       Impact factor: 2.419

10.  BPrevention of Cutaneous Tissue Contracture During Removal of Craniofacial Implant Superstructures for CT and MRI Studies.

Authors:  Maureen Sullivan; Rachael Rossitto; David Casey
Journal:  J Oral Maxillofac Res       Date:  2010-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.