Literature DB >> 26429261

Induced magnetic moment in stainless steel components of orthodontic appliances in 1.5 T MRI scanners.

Zhiyue J Wang1, Nancy K Rollins1, Hui Liang2, Yong Jong Park3.   

Abstract

PURPOSE: Most orthodontic appliances are made of stainless steel materials and induce severe magnetic susceptibility artifacts in brain MRI. In an effort for correcting these artifacts, it is important to know the value of induced magnetic moments in all parts of orthodontic appliances. In this study, the induced magnetic moment of stainless steel orthodontic brackets, molar bands, and arch-wires from several vendors is measured.
METHODS: Individual stainless steel brackets, molar bands, and short segments of arch-wire were positioned in the center of spherical flask filled with water through a thin plastic rod. The induced magnetic moment at 1.5 T was determined by fitting the B0 map to the z-component of the magnetic dipole field using a computer routine.
RESULTS: The induced magnetic moment at 1.5 T was dominated by the longitudinal component mz, with a small contribution from the transverse components. The mz was insensitive to the orientation of the metal parts. The orthodontic brackets collectively dominated the magnetic dipole moment in orthodontic appliances. In brackets from six vendors, the total induced mz from 20 brackets for nonmolar teeth ranged from 0.108 to 0.158 (median 0.122) A ⋅ m(2). The mz in eight molar bands with bracket attachment from two vendors ranged from 0.0004 to 0.0166 (median 0.0035) A ⋅ m(2). Several full length arch wires had induced magnetic moment in the range of 0.006-0.025 (median 0.015) A ⋅ m(2).
CONCLUSIONS: Orthodontic brackets collectively contributed most to the total magnetic moment. Different types of brackets, molar bands, and arch wires all exhibit substantial variability in the induced magnetic moment.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26429261      PMCID: PMC5148096          DOI: 10.1118/1.4930796

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems.

Authors:  J Kemper; A N Priest; D Schulze; B Kahl-Nieke; G Adam; A Klocke
Journal:  Eur Radiol       Date:  2006-06-29       Impact factor: 5.315

2.  MRI scanning and orthodontics.

Authors:  A Patel; G S Bhavra; J R S O'Neill
Journal:  J Orthod       Date:  2006-12

Review 3.  Orthodontic materials research and applications: part 2. Current status and projected future developments in materials and biocompatibility.

Authors:  Theodore Eliades
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-02       Impact factor: 2.650

4.  MR-imaging of the TMJ: artefacts caused by dental alloys.

Authors:  M Behr; C Fellner; G Bayreuther; A Leibrock; P Held; F Fellner; G Handel
Journal:  Eur J Prosthodont Restor Dent       Date:  1996-09

5.  Dental material artifacts on MR images.

Authors:  D B Hinshaw; B A Holshouser; H I Engstrom; A H Tjan; E L Christiansen; W F Catelli
Journal:  Radiology       Date:  1988-03       Impact factor: 11.105

6.  Influence of dental materials on dental MRI.

Authors:  O Tymofiyeva; S Vaegler; K Rottner; J Boldt; A J Hopfgartner; P C Proff; E J Richter; P M Jakob
Journal:  Dentomaxillofac Radiol       Date:  2013-04-22       Impact factor: 2.419

7.  Single-shot turbo spin-echo diffusion-weighted imaging for retinoblastoma: initial experience.

Authors:  P de Graaf; P J W Pouwels; F Rodjan; A C Moll; S M Imhof; D L Knol; E Sanchez; P van der Valk; J A Castelijns
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

8.  [Orthodontic brackets in high field MR imaging: experimental evaluation of magnetic field interactions at 3.0 Tesla].

Authors:  J Kemper; A Klocke; B Kahl-Nieke; G Adam
Journal:  Rofo       Date:  2005-12

9.  Effect of orthodontic brackets and different wires on radiofrequency heating and magnetic field interactions during 3-T MRI.

Authors:  S Görgülü; S Ayyildiz; K Kamburoglu; S Gökçe; T Ozen
Journal:  Dentomaxillofac Radiol       Date:  2013-11-20       Impact factor: 2.419

10.  Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging.

Authors:  P F New; B R Rosen; T J Brady; F S Buonanno; J P Kistler; C T Burt; W S Hinshaw; J H Newhouse; G M Pohost; J M Taveras
Journal:  Radiology       Date:  1983-04       Impact factor: 11.105

View more
  3 in total

1.  Microleakage beneath orthodontic brackets in high field magnetic resonance imaging (MRI) AT 1.5 & 3 Tesla.

Authors:  Esra Bolat Gümüş; Samed Şatir; Alper Kuştarci
Journal:  Dentomaxillofac Radiol       Date:  2022-02-09       Impact factor: 3.525

2.  Magnetic Resonance Imaging and Its Effects on Metallic Brackets and Wires: Does It Alter the Temperature and Bonding Efficacy of Orthodontic Devices?

Authors:  Maria Francesca Sfondrini; Lorenzo Preda; Fabrizio Calliada; Lorenzo Carbone; Luca Lungarotti; Luisa Bernardinelli; Paola Gandini; Andrea Scribante
Journal:  Materials (Basel)       Date:  2019-11-30       Impact factor: 3.623

3.  Correcting B0 Field Distortions in MRI Caused by Stainless Steel Orthodontic Appliances at 1.5 T Using Permanent Magnets - A Head Phantom Study.

Authors:  Zhiyue J Wang; Yong Jong Park; Michael C Morriss; Youngseob Seo; Trung Nguyen; Rami R Hallac; Ana Nava; Rajiv Chopra; Yonatan Chatzinoff; Khyana Price; Nancy K Rollins
Journal:  Sci Rep       Date:  2018-04-09       Impact factor: 4.379

  3 in total