| Literature DB >> 18922175 |
Cristiane Barbieri1, Jose G Cecatti, Carla E Souza, Emilio F Marussi, Jose V Costa.
Abstract
BACKGROUND: The purpose of the study was to evaluate inter- and intra-observer variability in sonographic measurements of the cross-sectional area of the umbilical cord and the diameters of its vessels in low-risk pregnancies of 12 to 40 weeks of gestation.Entities:
Year: 2008 PMID: 18922175 PMCID: PMC2572583 DOI: 10.1186/1742-4755-5-5
Source DB: PubMed Journal: Reprod Health ISSN: 1742-4755 Impact factor: 3.223
Figure 1Ultrasonographic measurement A. of the cross-sectional area of the umbilical cord (C), the diameter of the umbilical vein (V) and the umbilical artery (A); and B. of the longitudinal section of the umbilical cord (between 12 and 14 weeks).
Characteristics of study population
| Characteristics | n | % |
| Nulliparous | 103 | 46.6 |
| Previous abortion | 27 | 12.2 |
| At least one living child | 118 | 53.4 |
| White | 168 | 76.0 |
| Age (years) | ||
| 14 – 19 | 21 | 9.5 |
| 20 – 29 | 98 | 44.3 |
| 30 – 39 | 85 | 38.5 |
| 40 – 45 | 17 | 7.7 |
| Gestational age (weeks) | ||
| 14 – 16 | 7 | 3.2 |
| 17 – 21 | 23 | 10.4 |
| 22 – 24 | 23 | 10.4 |
| 25 – 28 | 43 | 19.5 |
| 29 – 32 | 50 | 22.6 |
| 33 – 36 | 30 | 13.6 |
| 37 – 40 | 45 | 20.4 |
| Total | 221 |
Inter-observer variability in the ultrasonographic measurements of the umbilical cord (n = 221)
| Characteristics | Mean Difference (SD) | 95%CI | p* | R | ICC | Crombach's alpha |
| Diameter of the cord (mm) | 0.024 (1.208) | (-0.136; 0.185) | 0.896 | 0.90 | 0.94 | 0.97 |
| Diameter of the artery (mm) | -0.057 (0.677) | (-0.147; 0.032) | 0.728 | 0.79 | 0.83 | 0.91 |
| Diameter of the vein (mm) | 0.045 (0.907) | (-0.075; 0.166) | 0.800 | 0.90 | 0.91 | 0.95 |
| Area of the cord (mm2) | 1.088 (30.120) | (-2.905; 5.081) | 0.903 | 0.90 | 0.92 | 0.96 |
* Mann-Whitney's non parametric test.
R: Spearman's correlation coefficient (p < 0.0001).
ICC: intraclass correlation coefficient (internal consistency).
Figure 2Inter-observer agreement by plotting the mean differences against the mean values (method of Bland & Altman) for the following measurements: A. Diameter of the umbilical cord (cord1 and cord2 are respectively the measurements of observer 1 and 2); and B. diameter of the area of the umbilical cord (area1 and area2 are respectively the measurements of observer 1 and 2).
Figure 3Linear correlation (r = correlation coefficient of Spearman) of the inter-observer ultra-sonographic measurements: A. of the diameter of the umbilical cord (cord1 and cord2 are respectively the measurements of observer 1 and 2); and B. of the cross-sectional area of the umbilical cord (area1 and area2 are respectively the measurements of observer 1 and 2).
Intra-observer variability in the ultrasonographic measurements of the umbilical cord (n = 221)
| Characteristics | Mean Difference (SD) | (95%CI) | p* | R | ICC | Crombach's alpha |
| Diameter of the cord (mm) | -0.120 (0.960) | (-0.248; 0.007) | 0.734 | 0.95 | 0.96 | 0.98 |
| Diameter of the artery (mm) | -0.137 (0.576) | (-0.213; -0.06) | 0.332 | 0.86 | 0.88 | 0.94 |
| Diameter of the vein (mm) | 0.011 (0.763) | (-0.09; 0.113) | 0.917 | 0.92 | 0.94 | 0.97 |
| Area of the cord (mm2) | -2.500 (24.390) | (-5.74; 0.73) | 0.732 | 0.95 | 0.95 | 0.97 |
* Mann-Whitney's non parametric test.
R: Spearman's correlation coefficient (p < 0.0001).
ICC: intraclass correlation coefficient (internal consistency)
Figure 4Linear correlation (r = correlation coefficient of Spearman) of the intra-observer ultrasonographic measurements: A. of the diameter of the umbilical cord (cord1 and cord3 are respectively the first and second measurements of observer 1); and B. of the cross-sectional area of the umbilical cord (area1 and area3 are respectively the first and second measurements of observer 1).