Literature DB >> 16076617

The umbilical cord thickness measured at 18-23 weeks of gestational age.

Mladen Predanic1, Sriram C Perni, Stephen T Chasen.   

Abstract

OBJECTIVE: To establish an umbilical cord thickness nomogram from anatomy ultrasound scans performed between 18 and 23 weeks of gestational age in singleton pregnancies, and compare it to two previously published nomograms.
MATERIAL AND METHODS: In this retrospective cohort study of 1107 patients, a total of 650 singleton pregnancies were included. The umbilical cord diameter measurements were performed at the level of fetal abdominal wall insertion, and were correlated with gestational age (GA) and estimated fetal weight (EFW). Statistical analysis with non-parametric polynomial least squares regression analysis was performed.
RESULTS: A statistically significant correlation between umbilical cord diameter and GA (P<0001, r=0.399, 95% CI 0.331 to 0.464), and EFW (P<0001, r=0.420, 95% CI 0.353-0.483) was observed. A nomogram of umbilical cord thickness according to GA (y), and EFW (y'), was generated from the following equations:y=-51.30+5.367*x-0.1165*x(2) and y'=6.917+0.007233*x, respectively.
CONCLUSION: Our nomogram is in agreement with one of the previously published nomograms that also measured umbilical cord diameter at the level of the fetal abdominal umbilical cord insertion. Therefore, we recommend umbilical cord thickness to be measured in close proximity to the fetal abdominal wall, but no further than 0.5 cm away from the wall insertion.

Entities:  

Mesh:

Year:  2005        PMID: 16076617     DOI: 10.1080/14767050500042824

Source DB:  PubMed          Journal:  J Matern Fetal Neonatal Med        ISSN: 1476-4954


  3 in total

1.  Is there any relation between umbilical artery and vein diameter and estimated fetal weight in healthy pregnant women?

Authors:  Aydın Köşüş; Nermin Köşüş; Nilgün Ö Turhan
Journal:  J Med Ultrason (2001)       Date:  2012-05-09       Impact factor: 1.314

2.  Evaluation of umbilical cord thickness, cross-sectional area, and coiling index as predictors of pregnancy outcome.

Authors:  Morteza Tahmasebi; Reza Alighanbari
Journal:  Indian J Radiol Imaging       Date:  2011-07

3.  Inter- and intra-observer variability in Sonographic measurements of the cross-sectional diameters and area of the umbilical cord and its vessels during pregnancy.

Authors:  Cristiane Barbieri; Jose G Cecatti; Carla E Souza; Emilio F Marussi; Jose V Costa
Journal:  Reprod Health       Date:  2008-10-15       Impact factor: 3.223

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.