Literature DB >> 9464727

The clinical significance of antenatal detection of discordant umbilical arteries.

L Raio1, F Ghezzi, E Di Naro, R Gomez, G Saile, H Brühwiler.   

Abstract

OBJECTIVE: To evaluate the clinical significance of the antenatally detected discordant umbilical arteries (UAs).
METHODS: Women with singleton gestations undergoing sonographic evaluations were examined for the presence of discordant UAs. Transverse and longitudinal diameters as well as the area of both UAs were measured. Doppler flow velocity waveforms were recorded from both arteries. Macroscopic and microscopic examination of the umbilical cord was performed after delivery and the area of each artery was measured. Mann-Whitney U test and Spearman rank correlation were used for statistical purposes.
RESULTS: Data are presented as median (range). Discordance between UAs was found in 14 of 1012 women who underwent sonographic examinations. The vessel diameters and areas differed significantly between the discordant UAs (diameter 2.9 [1-4.3] versus 4.5 [3.8-6.5] mm, P < .001; area 6.6 [0.78-14.5] versus 16.25 [11.33-33.16] mm2, P < .001). A significant difference between UA size was confirmed after delivery (area 1.68 [0.9-3.06] versus 4.17 [1.12-13.8] mm2, P < .005). The difference in the area of the UAs in utero and at microscopic examination correlated significantly (r = .94, P < .05). In all cases, the resistance index was higher in the smaller artery than in the larger artery (0.71 [0.59-0.8] versus 0.6 [0.48-0.75] P < .01). Abnormal insertion of the umbilical cord or an abnormality of the placenta was present in eight cases. Perinatal death occurred only in a trisomic infant born at 24 weeks' gestation.
CONCLUSION: The clinical significance of discordant UAs is that newborns are generally in good condition at birth and placental anomalies are common in this group of parturients. Abnormal Doppler velocimetry of the smaller UA should be taken with caution, because it does not seem to be associated with poor perinatal outcome.

Entities:  

Mesh:

Year:  1998        PMID: 9464727     DOI: 10.1016/s0029-7844(97)00543-7

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  3 in total

1.  Antenatal assessment of discordant umbilical arteries in singleton pregnancies.

Authors:  Mladen Predanic; Sriram C Perni
Journal:  Croat Med J       Date:  2006-10       Impact factor: 1.351

2.  Doppler Ultrasound of the Fetal Descending Aorta: An Objective Tool to Assess Placental Blood Flow Resistance in Pregnancies With Discordant Umbilical Arteries.

Authors:  Lindsay S Cahill; Grace V Mercer; Dakshita Jagota; Anjana Ravi Chandran; Natasha Milligan; Shiri Shinar; Clare L Whitehead; Sebastian R Hobson; Lena Serghides; W Tony Parks; Christopher K Macgowan; John C Kingdom; John G Sled; Ahmet A Baschat
Journal:  J Ultrasound Med       Date:  2021-07-06       Impact factor: 2.153

3.  Inter- and intra-observer variability in Sonographic measurements of the cross-sectional diameters and area of the umbilical cord and its vessels during pregnancy.

Authors:  Cristiane Barbieri; Jose G Cecatti; Carla E Souza; Emilio F Marussi; Jose V Costa
Journal:  Reprod Health       Date:  2008-10-15       Impact factor: 3.223

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.