Literature DB >> 17042061

Antenatal assessment of discordant umbilical arteries in singleton pregnancies.

Mladen Predanic1, Sriram C Perni.   

Abstract

AIM: To assess the relationship between discordant umbilical arterial size and resultant blood flow parameters and determine the impact of discordance on fetal outcome.
METHODS: This is a descriptive, cross-sectional study of 200 patients with a singleton gestation, who underwent a fetal anatomy survey between 18 to 23 weeks of gestation, with documented umbilical cord morphological patterns and blood flow characteristics. Umbilical vessel diameters and Doppler parameters (umbilical vein blood flow volume, mean resistance index, and peak-systolic velocity) were analyzed for discordance. Discordances encountered were examined for their possible association with perinatal outcome.
RESULTS: We had adequate ultrasound umbilical cord images, Doppler flow parameters, and all necessary demographic data for 154 patients. Umbilical artery discordance averaged 13.1% and was significantly correlated with both the expected and the true percent of difference in resistance index values (RI, P<0.001). In 12 patients (7.8%), a significant discordance of more than 29.5%, or 95th percentile, was observed between the two umbilical artery diameters. However, in these cases no associated adverse perinatal outcome or significant placental pathology was noted. There was no significant difference between patients discordant or concordant umbilical artery in terms of maternal, labor, and neonatal data.
CONCLUSION: The magnitude of umbilical arteries' luminal discordance directly influences the corresponding blood flow parameters. In our sample of patients, the presence of discordant-in-size umbilical arteries was not associated with umbilical cord or placental abnormalities.

Entities:  

Mesh:

Year:  2006        PMID: 17042061      PMCID: PMC2080471     

Source DB:  PubMed          Journal:  Croat Med J        ISSN: 0353-9504            Impact factor:   1.351


  14 in total

1.  In-utero characterization of the blood flow in the Hyrtl anastomosis.

Authors:  L Raio; F Ghezzi; E di Naro; M Franchi; D Balestreri; P Dürig; H Schneider
Journal:  Placenta       Date:  2001-07       Impact factor: 3.481

2.  Sonographic estimation of umbilical coiling index and correlation with Doppler flow characteristics.

Authors:  S Degani; R M Lewinsky; H Berger; D Spiegel
Journal:  Obstet Gynecol       Date:  1995-12       Impact factor: 7.661

3.  Discordant umbilical arteries: ultrasonographic and Doppler analysis.

Authors:  L A Dolkart; F T Reimers; C A Kuonen
Journal:  Obstet Gynecol       Date:  1992-01       Impact factor: 7.661

4.  Disparate blood flow patterns in parallel umbilical arteries.

Authors:  M Predanic; J Kolli; P Yousefzadeh; J Pennisi
Journal:  Obstet Gynecol       Date:  1998-05       Impact factor: 7.661

5.  The clinical significance of antenatal detection of discordant umbilical arteries.

Authors:  L Raio; F Ghezzi; E Di Naro; R Gomez; G Saile; H Brühwiler
Journal:  Obstet Gynecol       Date:  1998-01       Impact factor: 7.661

6.  Hyrtl's anastomosis, the only connection between the two umbilical arteries. A study in full term placentas from AGA infants with normal umbilical artery blood flow.

Authors:  U Ullberg; B Sandstedt; G Lingman
Journal:  Acta Obstet Gynecol Scand       Date:  2001-01       Impact factor: 3.636

7.  Antenatal diagnosis of aberrant umbilical vessels.

Authors:  S Aoki; T Hata; Y Ariyuki; K Makihara; K Hata; M Kitao
Journal:  Gynecol Obstet Invest       Date:  1997       Impact factor: 2.031

8.  A review of second-order effects on Poiseuille's equation for application to blood and other viscous fluids.

Authors:  E F Blick; P D Stein
Journal:  Med Res Eng       Date:  1972

9.  Sonographic measurements of the umbilical cord and vessels during normal pregnancies.

Authors:  A Weissman; P Jakobi; M Bronshtein; I Goldstein
Journal:  J Ultrasound Med       Date:  1994-01       Impact factor: 2.153

10.  Single umbilical artery. A statistical analysis of 237 autopsy cases and review of the literature.

Authors:  S A Heifetz
Journal:  Perspect Pediatr Pathol       Date:  1984
View more
  3 in total

1.  Doppler Ultrasound of the Fetal Descending Aorta: An Objective Tool to Assess Placental Blood Flow Resistance in Pregnancies With Discordant Umbilical Arteries.

Authors:  Lindsay S Cahill; Grace V Mercer; Dakshita Jagota; Anjana Ravi Chandran; Natasha Milligan; Shiri Shinar; Clare L Whitehead; Sebastian R Hobson; Lena Serghides; W Tony Parks; Christopher K Macgowan; John C Kingdom; John G Sled; Ahmet A Baschat
Journal:  J Ultrasound Med       Date:  2021-07-06       Impact factor: 2.153

2.  Inter- and intra-observer variability in Sonographic measurements of the cross-sectional diameters and area of the umbilical cord and its vessels during pregnancy.

Authors:  Cristiane Barbieri; Jose G Cecatti; Carla E Souza; Emilio F Marussi; Jose V Costa
Journal:  Reprod Health       Date:  2008-10-15       Impact factor: 3.223

3.  Development of a Bioartificial Vascular Pancreas.

Authors:  Edward X Han; Juan Wang; Mehmet Kural; Bo Jiang; Katherine L Leiby; Nazar Chowdhury; George Tellides; Richard G Kibbey; Jeffrey H Lawson; Laura E Niklason
Journal:  J Tissue Eng       Date:  2021-06-28       Impact factor: 7.813

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.