MR relaxation times in human brain: measurement at 4 T.

P Jezzard1, S Duewell, R S Balaban.   

Abstract

PURPOSE: To determine the values for relaxation times in human brain for magnetic resonance (MR) imaging at 4 T.
MATERIALS AND METHODS: T1 measurements were made with a progressive saturation sequence, an implementation of the Look-Locker sequence, and an inversion-recovery (IR) interleaved echo-planar imaging (IEPI) sequence. T2 measurements were made with a standard spin-echo (SE) sequence and an SE IEPI sequence.
RESULTS: The T1 measurements yielded values of 1,724 msec +/- 51 for gray matter, 1,043 msec +/- 27 for white matter, and 4,550 msec +/- 800 msec for cerebrospinal fluid. The deep gray matter regions had T1 values of 1,458 +/- 38 (caudate nucleus) and 1,372 +/- 60 (putamen). The T2 measurements yielded results of 63 msec +/- 6.2 for gray matter and 49.8 msec +/- 2.2 for white matter.
CONCLUSION: The T1 values measured at 4 T show a higher value than predicted from extrapolation at lower field strengths. The T2 measurements showed a slight decrease in values over those measured at lower-field strength. The gain in signal-to-noise ratio from the higher field strength may be substantially offset by these altered relaxation time values to a degree that is sequence dependent.

Entities:  

Mesh:

Year:  1996        PMID: 8638004     DOI: 10.1148/radiology.199.3.8638004

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  28 in total

1.  Multivoxel 3D proton spectroscopy in the brain at 1.5 versus 3.0 T: signal-to-noise ratio and resolution comparison.

Authors:  O Gonen; S Gruber; B S Li; V Mlynárik; E Moser
Journal:  AJNR Am J Neuroradiol       Date:  2001-10       Impact factor: 3.825

2.  Magnetic resonance imaging protocols for examination of the neurocranium at 3 T.

Authors:  W Schwindt; H Kugel; R Bachmann; S Kloska; T Allkemper; D Maintz; B Pfleiderer; B Tombach; W Heindel
Journal:  Eur Radiol       Date:  2003-07-05       Impact factor: 5.315

Review 3.  Prostate MR imaging at high-field strength: evolution or revolution?

Authors:  Olivier Rouvière; Robert P Hartman; Denis Lyonnet
Journal:  Eur Radiol       Date:  2005-09-10       Impact factor: 5.315

Review 4.  Foundations of advanced magnetic resonance imaging.

Authors:  Roland Bammer; Stefan Skare; Rexford Newbould; Chunlei Liu; Vincent Thijs; Stefan Ropele; David B Clayton; Gunnar Krueger; Michael E Moseley; Gary H Glover
Journal:  NeuroRx       Date:  2005-04

5.  High-resolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla.

Authors:  Seshasailaja Anumula; Hee Kwon Song; Alexander C Wright; Felix W Wehrli
Journal:  Acad Radiol       Date:  2005-12       Impact factor: 3.173

6.  Measurement of Signal-to-Noise and Contrast-to-Noise in the fBIRN Multicenter Imaging Study.

Authors:  Vincent A Magnotta; Lee Friedman
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

7.  Apparent diffusion coefficient reveals gray and white matter disease, and T2 mapping detects white matter disease in the brain in feline alpha-mannosidosis.

Authors:  C H Vite; S Magnitsky; D Aleman; P O'Donnell; K Cullen; W Ding; S Pickup; J H Wolfe; H Poptani
Journal:  AJNR Am J Neuroradiol       Date:  2007-11-01       Impact factor: 3.825

8.  Magnetic field dependence of the distribution of NMR relaxation times in the living human brain.

Authors:  A M Oros-Peusquens; M Laurila; N J Shah
Journal:  MAGMA       Date:  2008-03-13       Impact factor: 2.310

9.  Assessment of the effects of cellular tissue properties on ADC measurements by numerical simulation of water diffusion.

Authors:  Kevin D Harkins; Jean-Philippe Galons; Timothy W Secomb; Theodore P Trouard
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

10.  Reducing ghosting due to k-space discontinuities in fast spin echo (FSE) imaging by a new combination of k-space ordering and parallel imaging.

Authors:  David W Carmichael; David L Thomas; Roger J Ordidge
Journal:  J Magn Reson       Date:  2009-06-21       Impact factor: 2.229

View more