Literature DB >> 18823731

Carr-Purcell-Meiboom-Gill imaging of prostate cancer: quantitative T2 values for cancer discrimination.

Joseph R Roebuck1, Steven J Haker, Dimitris Mitsouras, Frank J Rybicki, Clare M Tempany, Robert V Mulkern.   

Abstract

Quantitative, apparent T(2) values of suspected prostate cancer and healthy peripheral zone tissue in men with prostate cancer were measured using a Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence in order to assess the cancer discrimination potential of tissue T(2) values. The CPMG imaging sequence was used to image the prostates of 18 men with biopsy-proven prostate cancer. Whole gland coverage with nominal voxel volumes of 0.54 x 1.1 x 4 mm(3) was obtained in 10.7 min, resulting in data sets suitable for generating high-quality images with variable T(2)-weighting and for evaluating quantitative T(2) values on a pixel-by-pixel basis. Region-of-interest analysis of suspected healthy peripheral zone tissue and suspected cancer, identified on the basis of both T(1)- and T(2)-weighted signal intensities and available histopathology reports, yielded significantly (P<.0001) longer apparent T(2) values in suspected healthy tissue (193+/-49 ms) vs. suspected cancer (100+/-26 ms), suggesting potential utility of this method as a tissue specific discrimination index for prostate cancer. We conclude that CPMG imaging of the prostate can be performed in reasonable scan times and can provide advantages over T(2)-weighted fast spin echo (FSE) imaging alone, including quantitative T(2) values for cancer discrimination as well as proton density maps without the point spread function degradation associated with short effective echo time FSE sequences.

Entities:  

Mesh:

Year:  2008        PMID: 18823731      PMCID: PMC2720831          DOI: 10.1016/j.mri.2008.08.001

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  27 in total

Review 1.  Imaging prostate cancer.

Authors:  K K Yu; H Hricak
Journal:  Radiol Clin North Am       Date:  2000-01       Impact factor: 2.303

2.  Comparison of quantitative T2 mapping and diffusion-weighted imaging in the normal and pathologic prostate.

Authors:  P Gibbs; D J Tozer; G P Liney; L W Turnbull
Journal:  Magn Reson Med       Date:  2001-12       Impact factor: 4.668

3.  Detection of prostate cancer by integration of line-scan diffusion, T2-mapping and T2-weighted magnetic resonance imaging; a multichannel statistical classifier.

Authors:  Ian Chan; William Wells; Robert V Mulkern; Steven Haker; Jianqing Zhang; Kelly H Zou; Stephan E Maier; Clare M C Tempany
Journal:  Med Phys       Date:  2003-09       Impact factor: 4.071

4.  Osmotic effects on the T2 relaxation decay of in vivo muscle.

Authors:  G Gambarota; B E Cairns; C B Berde; R V Mulkern
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

5.  Prostate cancer: localization with three-dimensional proton MR spectroscopic imaging--clinicopathologic study.

Authors:  J Scheidler; H Hricak; D B Vigneron; K K Yu; D L Sokolov; L R Huang; C J Zaloudek; S J Nelson; P R Carroll; J Kurhanewicz
Journal:  Radiology       Date:  1999-11       Impact factor: 11.105

Review 6.  Prostate cancer: assessment of risk using digital rectal examination, tumor grade, prostate-specific antigen, and systematic biopsy.

Authors:  J C Presti
Journal:  Radiol Clin North Am       Date:  2000-01       Impact factor: 2.303

7.  In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo-planar imaging.

Authors:  Bashar Issa
Journal:  J Magn Reson Imaging       Date:  2002-08       Impact factor: 4.813

8.  Discrimination of prostate cancer from normal peripheral zone and central gland tissue by using dynamic contrast-enhanced MR imaging.

Authors:  Marc R Engelbrecht; Henkjan J Huisman; Robert J F Laheij; Gerrit J Jager; Geert J L H van Leenders; Christina A Hulsbergen-Van De Kaa; Jean J M C H de la Rosette; Johan G Blickman; Jelle O Barentsz
Journal:  Radiology       Date:  2003-08-27       Impact factor: 11.105

Review 9.  [MR imaging of prostate cancer].

Authors:  A Heuck; J Scheidler; B Sommer; A Graser; U G Müller-Lisse; J Massmann
Journal:  Radiologe       Date:  2003-06       Impact factor: 0.635

10.  Combined T2-weighted and diffusion-weighted MRI for localization of prostate cancer.

Authors:  Masoom A Haider; Theodorus H van der Kwast; Jeff Tanguay; Andrew J Evans; Ali-Tahir Hashmi; Gina Lockwood; John Trachtenberg
Journal:  AJR Am J Roentgenol       Date:  2007-08       Impact factor: 3.959

View more
  16 in total

1.  Quantification of Nonenhancing Tumor Burden in Gliomas Using Effective T2 Maps Derived from Dual-Echo Turbo Spin-Echo MRI.

Authors:  Benjamin M Ellingson; Albert Lai; Huytram N Nguyen; Phioanh L Nghiemphu; Whitney B Pope; Timothy F Cloughesy
Journal:  Clin Cancer Res       Date:  2015-04-21       Impact factor: 12.531

2.  A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.

Authors:  Yoichi Watanabe; Hitoshi Kubo
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

3.  Characterization of gradient echo signal decays in healthy and cancerous prostate at 3T improves with a Gaussian augmentation of the mono-exponential (GAME) model.

Authors:  Pelin Aksit Ciris; Mukund Balasubramanian; Ravi T Seethamraju; Junichi Tokuda; Jonathan Scalera; Tobias Penzkofer; Fiona M Fennessy; Clare M Tempany-Afdhal; Kemal Tuncali; Robert V Mulkern
Journal:  NMR Biomed       Date:  2016-05-31       Impact factor: 4.044

4.  Prostate cancer discrimination in the peripheral zone with a reduced field-of-view T(2)-mapping MRI sequence.

Authors:  Fernando I Yamauchi; Tobias Penzkofer; Andriy Fedorov; Fiona M Fennessy; Renxin Chu; Stephan E Maier; Clare M C Tempany; Robert V Mulkern; Lawrence P Panych
Journal:  Magn Reson Imaging       Date:  2015-02-14       Impact factor: 2.546

5.  Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM/NIST MRI system phantom.

Authors:  Yun Jiang; Dan Ma; Kathryn E Keenan; Karl F Stupic; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2016-10-27       Impact factor: 4.668

6.  3-T MR-guided brachytherapy for gynecologic malignancies.

Authors:  Tina Kapur; Jan Egger; Antonio Damato; Ehud J Schmidt; Akila N Viswanathan
Journal:  Magn Reson Imaging       Date:  2012-08-13       Impact factor: 2.546

7.  Immobilized contrast-enhanced MRI: Gadolinium-based long-term MR contrast enhancement of the vein graft vessel wall.

Authors:  Dimitris Mitsouras; Praveen Kumar Vemula; Peng Yu; Ming Tao; Binh T Nguyen; Christina M Campagna; Jeffrey M Karp; Robert V Mulkern; C Keith Ozaki; Frank J Rybicki
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

Review 8.  Multiparametric MRI of prostate cancer: an update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer.

Authors:  John V Hegde; Robert V Mulkern; Lawrence P Panych; Fiona M Fennessy; Andriy Fedorov; Stephan E Maier; Clare M C Tempany
Journal:  J Magn Reson Imaging       Date:  2013-05       Impact factor: 4.813

9.  Performance of a fast and high-resolution multi-echo spin-echo sequence for prostate T2 mapping across multiple systems.

Authors:  Petra J van Houdt; Harsh K Agarwal; Laurens D van Buuren; Stijn W T P J Heijmink; Søren Haack; Henk G van der Poel; Ghazaleh Ghobadi; Floris J Pos; Johannes M Peeters; Peter L Choyke; Uulke A van der Heide
Journal:  Magn Reson Med       Date:  2017-07-03       Impact factor: 4.668

10.  Rapid and accurate T2 mapping from multi-spin-echo data using Bloch-simulation-based reconstruction.

Authors:  Noam Ben-Eliezer; Daniel K Sodickson; Kai Tobias Block
Journal:  Magn Reson Med       Date:  2014-03-19       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.