Literature DB >> 20859994

Immobilized contrast-enhanced MRI: Gadolinium-based long-term MR contrast enhancement of the vein graft vessel wall.

Dimitris Mitsouras1, Praveen Kumar Vemula, Peng Yu, Ming Tao, Binh T Nguyen, Christina M Campagna, Jeffrey M Karp, Robert V Mulkern, C Keith Ozaki, Frank J Rybicki.   

Abstract

An implantable MR contrast agent that can be covalently immobilized on tissue during surgery has been developed. The rationale is that a durable increase in tissue contrast using an implantable contrast agent can enhance postsurgical tissue differentiation using MRI. For small-vessel (e.g., vein graft) MRI, the direct benefit of such permanent "labeling" of the vessel wall by modification of its relaxation properties is to achieve more efficient imaging. This efficiency can be realized as either increased contrast leading to more accurate delineation of vessel wall and lesion tissue boundaries, or, faster imaging without penalizing contrast-to-noise ratio, or a combination thereof. We demonstrate, for the first time, stable long-term MRI enhancement using such an exogenous contrast mechanism based on immobilizing a modified diethylenetriaminepentaacetic acid gadolinium(3+) dihydrogen complex on a human vein using a covalent amide bond. Signal enhancement due to the covalently immobilized contrast agent is demonstrated for excised human vein specimens imaged at 3 T, and its long-term stability is demonstrated during a 4-month incubation period.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20859994      PMCID: PMC3005031          DOI: 10.1002/mrm.22606

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement.

Authors:  Lindsey A Crowe; Peter Gatehouse; Guang Zhong Yang; Raad H Mohiaddin; Anitha Varghese; Clare Charrier; Jennifer Keegan; David N Firmin
Journal:  J Magn Reson Imaging       Date:  2003-05       Impact factor: 4.813

2.  Lumen loss in the first year in saphenous vein grafts is predominantly a result of negative remodeling of the whole vessel rather than a result of changes in wall thickness.

Authors:  George T Lau; Lloyd J Ridley; Paul G Bannon; Louise A Wong; Joseph Trieu; David B Brieger; Harry C Lowe; Ben S Freedman; Leonard Kritharides
Journal:  Circulation       Date:  2006-07-04       Impact factor: 29.690

3.  Rationale and applications for macromolecular Gd-based contrast agents.

Authors:  R C Brasch
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

4.  High-resolution peripheral vein bypass graft wall studies using high sampling efficiency inner volume 3D FSE.

Authors:  Dimitris Mitsouras; Robert V Mulkern; Christopher D Owens; Michael S Conte; Hale Ersoy; Tuan M Luu; Amanda G Whitmore; Mark A Creager; Frank J Rybicki
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

5.  Chemical engineering of mesenchymal stem cells to induce a cell rolling response.

Authors:  Debanjan Sarkar; Praveen Kumar Vemula; Grace S L Teo; Dawn Spelke; Rohit Karnik; Le Y Wee; Jeffrey M Karp
Journal:  Bioconjug Chem       Date:  2008-11-19       Impact factor: 4.774

6.  The interaction of MS-325 with human serum albumin and its effect on proton relaxation rates.

Authors:  Peter Caravan; Normand J Cloutier; Matthew T Greenfield; Sarah A McDermid; Stephen U Dunham; Jeff W M Bulte; John C Amedio; Richard J Looby; Ronald M Supkowski; William DeW Horrocks; Thomas J McMurry; Randall B Lauffer
Journal:  J Am Chem Soc       Date:  2002-03-27       Impact factor: 15.419

7.  In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

Authors:  Dimitris Mitsouras; Christopher D Owens; Michael S Conte; Hale Ersoy; Mark A Creager; Frank J Rybicki; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

8.  Improved characterization of atherosclerotic plaques by gadolinium contrast during intravascular magnetic resonance imaging of human arteries.

Authors:  Eric Larose; Scott Kinlay; Andrew P Selwyn; Yerem Yeghiazarians; E Kent Yucel; Daniel F Kacher; Peter Libby; Peter Ganz
Journal:  Atherosclerosis       Date:  2007-03-27       Impact factor: 5.162

9.  Lower extremity peripheral vein bypass graft wall thickness changes demonstrated at 1 and 6 months after surgery with ultra-high spatial resolution black blood inner volume three-dimensional fast spin echo magnetic resonance imaging.

Authors:  Frank John Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda G Whitmore; Hale Ersoy; Robert V Mulkern; Mark A Creager; Michael S Conte
Journal:  Int J Cardiovasc Imaging       Date:  2007-12-14       Impact factor: 2.357

10.  Prediction of the localization of high-risk coronary atherosclerotic plaques on the basis of low endothelial shear stress: an intravascular ultrasound and histopathology natural history study.

Authors:  Yiannis S Chatzizisis; Michael Jonas; Ahmet U Coskun; Roy Beigel; Benjamin V Stone; Charles Maynard; Ross G Gerrity; William Daley; Campbell Rogers; Elazer R Edelman; Charles L Feldman; Peter H Stone
Journal:  Circulation       Date:  2008-02-04       Impact factor: 29.690

View more
  1 in total

1.  Early animal model evaluation of an implantable contrast agent to enhance magnetic resonance imaging of arterial bypass vein grafts.

Authors:  Dimitrios Mitsouras; Ming Tao; Margreet R de Vries; Kaspar Trocha; Oscar R Miranda; Praveen Kumar Vemula; Kui Ding; Amir Imanzadeh; Frederick J Schoen; Jeffrey M Karp; C Keith Ozaki; Frank J Rybicki
Journal:  Acta Radiol       Date:  2018-01-29       Impact factor: 1.990

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.