Literature DB >> 18789794

Maximizing satisfaction with presbyopia-correcting intraocular lenses: the missing links.

Jay S Pepose1.   

Abstract

PURPOSE: To critically analyze recent studies of presbyopia-correcting intraocular lenses (IOLs) and to examine opportunities to enhance patient satisfaction further.
DESIGN: Perspective.
METHODS: Literature review and commentary.
RESULTS: Although overall patient satisfaction with the currently available presbyopia-correcting IOLs remains high, it is not uniform. Current accommodating or multifocal IOL designs are hampered by limited accommodative ability or reduced contrast sensitivity and photic phenomenon, respectively. Toric IOLs and IOLs inserted through smaller incisions minimize postoperative wound healing changes. Better assessment of total ocular characteristics, including corneal wavefront and pupil size and dynamics, will allow further IOL customization to each patient.
CONCLUSIONS: Postoperative modification of IOLs may offset variations in postoperative healing that cannot be predicted before surgery. Further methods to assess and modify neural adaptive capability are needed. Newer IOL designs may enhance functional depth of field further without compromising contrast sensitivity or inducing photic phenomena.

Entities:  

Mesh:

Year:  2008        PMID: 18789794     DOI: 10.1016/j.ajo.2008.07.033

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  19 in total

1.  Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation.

Authors:  G Prakash; D R Prakash; A Agarwal; D A Kumar; A Agarwal; S Jacob
Journal:  Eye (Lond)       Date:  2011-06-17       Impact factor: 3.775

2.  Haigis and SRKT formulae accuracy for intentional myopic overcorrection.

Authors:  Rodrigo Faeda Dalto; Miriam A Ferreira; Wilian Queiroz; Roberto Pinto Coelho; Jayter Silva Paula; Andre Messias
Journal:  Int Ophthalmol       Date:  2017-06-21       Impact factor: 2.031

Review 3.  Clinical application of accommodating intraocular lens.

Authors:  You-Ling Liang; Song-Bai Jia
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

4.  Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system.

Authors:  Myoung Joon Kim; Len Zheleznyak; Scott Macrae; Hungwon Tchah; Geunyoung Yoon
Journal:  J Cataract Refract Surg       Date:  2011-07       Impact factor: 3.351

5.  Clinical evaluation of two multifocal intraocular lens implantation patterns.

Authors:  Hao-Tian Lin; Wei-Rong Chen; Zhao-Feng Ding; Wan Chen; Chang-Rui Wu
Journal:  Int J Ophthalmol       Date:  2012-02-18       Impact factor: 1.779

6.  [Effect of intrastromal correction of presbyopia with femtosecond laser (INTRACOR) on mesopic contrast sensitivity].

Authors:  A Fitting; N Menassa; G U Auffarth; M P Holzer
Journal:  Ophthalmologe       Date:  2012-10       Impact factor: 1.059

7.  Comparison of through-focus image quality across five presbyopia-correcting intraocular lenses (an American Ophthalmological Society thesis).

Authors:  Jay S Pepose; Daozhi Wang; Griffith E Altmann
Journal:  Trans Am Ophthalmol Soc       Date:  2011-12

8.  Wavefront analysis and modulation transfer function of three multifocal intraocular lenses.

Authors:  Marcony R Santhiago; Marcelo V Netto; Jackson Barreto; Beatriz A F Gomes; Arthur Schaefer; Newton Kara-Junior
Journal:  Indian J Ophthalmol       Date:  2010 Mar-Apr       Impact factor: 1.848

9.  Dissatisfaction after multifocal intraocular lens implantation.

Authors:  Maria A Woodward; J Bradley Randleman; R Doyle Stulting
Journal:  J Cataract Refract Surg       Date:  2009-06       Impact factor: 3.351

10.  A contralateral eye study comparing apodized diffractive and full diffractive lenses: wavefront analysis and distance and near uncorrected visual acuity.

Authors:  Marcony Rodrigues de Santhiago; Marcelo Vieira Netto; Jackson Barreto; Beatriz de Abreu Fiuza Gomes; Arthur Schaefer; Newton Kara-Junior
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.