Literature DB >> 22253489

Comparison of through-focus image quality across five presbyopia-correcting intraocular lenses (an American Ophthalmological Society thesis).

Jay S Pepose1, Daozhi Wang, Griffith E Altmann.   

Abstract

PURPOSE: To assess through-focus polychromatic image sharpness of five US Food and Drug Administration-approved presbyopia-correcting intraocular lenses (IOLs) through a range of object vergences and pupil diameters utilizing an image sharpness algorithm.
METHODS: A 1951 US Air Force resolution target was imaged through a Crystalens AO (AO) (Bausch & Lomb Surgical, Aliso Viejo, California), Crystalens HD (HD) (Bausch & Lomb Surgical, Aliso Viejo, California), aspheric ReSTOR +4.0 (R4) (Alcon Laboratories, Fort Worth, Texas), aspheric ReSTOR +3.0 (R3) (Alcon Laboratories, Fort Worth, Texas), and Tecnis Multifocal Acrylic (TMF) (Abbott Medical Optics, Irvine, California) IOL in an anatomically and optically accurate model eye and captured digitally for each combination of pupil diameter and object vergence. The sharpness of each digital image was objectively scored using a two-dimensional gradient function.
RESULTS: The AO lens had the best distance image sharpness for all pupil diameters, followed by the HD. With a 5-mm pupil, the R4 lens achieved distance image quality similar to the HD, but inferior to the AO. The R3 successfully moved the near focal point farther from the patient compared to the R4, but did not improve image sharpness at intermediate distances and showed worse distance and near image sharpness. Consistent with apodization, the ReSTOR IOLs displayed better distance and poorer near image sharpness as pupil diameter increased. The TMF lens showed consistent distance and near image sharpness across pupil diameters and exhibited the best near image sharpness for all pupil diameters.
CONCLUSIONS: Differing IOL design strategies to increase depth of field are associated with quantifiable differences in image sharpness at varying vergences and pupil sizes. An objective comparison of the imaging properties of specific presbyopia-correcting IOLs, in conjunction with patients' pupil sizes, can be useful in selecting the most appropriate IOL for each patient.

Entities:  

Mesh:

Year:  2011        PMID: 22253489      PMCID: PMC3259672     

Source DB:  PubMed          Journal:  Trans Am Ophthalmol Soc        ISSN: 0065-9533


  52 in total

1.  Performance of presbyopia-correcting intraocular lenses in distance optical bench tests.

Authors:  W Andrew Maxwell; Stephen S Lane; Fan Zhou
Journal:  J Cataract Refract Surg       Date:  2009-01       Impact factor: 3.351

2.  Pupil sizes in different Japanese age groups and the implications for intraocular lens choice.

Authors:  Kunihiko Nakamura; Hiroko Bissen-Miyajima; Shinichi Oki; Kazuhiko Onuma
Journal:  J Cataract Refract Surg       Date:  2009-01       Impact factor: 3.351

3.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

4.  Assessing the optical performance of multifocal (diffractive) intraocular lenses.

Authors:  Timo Eppig; Katja Scholz; Achim Langenbucher
Journal:  Ophthalmic Physiol Opt       Date:  2008-09       Impact factor: 3.117

5.  Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a +3.0 or +4.0 diopter addition power Randomized multicenter clinical study.

Authors:  W Andrew Maxwell; Robert J Cionni; Robert P Lehmann; Satish S Modi
Journal:  J Cataract Refract Surg       Date:  2009-12       Impact factor: 3.351

6.  Visual function after implantation of an aspheric bifocal intraocular lens.

Authors:  José F Alfonso; Luis Fernández-Vega; Hussein Amhaz; Robert Montés-Micó; Beatriz Valcárcel; Teresa Ferrer-Blasco
Journal:  J Cataract Refract Surg       Date:  2009-05       Impact factor: 3.351

7.  Intraindividual comparison of the effect of training on visual performance with ReSTOR and Tecnis diffractive multifocal IOLs.

Authors:  Hakan Kaymak; Manfred Fahle; Gregor Ott; Ulrich Mester
Journal:  J Refract Surg       Date:  2008-03       Impact factor: 3.573

8.  An image based auto-focusing algorithm for digital fundus photography.

Authors:  Michele Moscaritolo; Henry Jampel; Frederick Knezevich; Ran Zeimer
Journal:  IEEE Trans Med Imaging       Date:  2009-04-10       Impact factor: 10.048

9.  Global vision impairment due to uncorrected presbyopia.

Authors:  Brien A Holden; Timothy R Fricke; S May Ho; Reg Wong; Gerhard Schlenther; Sonja Cronjé; Anthea Burnett; Eric Papas; Kovin S Naidoo; Kevin D Frick
Journal:  Arch Ophthalmol       Date:  2008-12

10.  Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models.

Authors:  Alfredo Castillo-Gómez; David Carmona-González; José María Martínez-de-la-Casa; Carlos Palomino-Bautista; Julián García-Feijoo
Journal:  J Cataract Refract Surg       Date:  2009-07       Impact factor: 3.351

View more
  3 in total

1.  Influence of spherical aberration, stimulus spatial frequency, and pupil apodisation on subjective refractions.

Authors:  Arthur Bradley; Renfeng Xu; Larry Thibos; Gildas Marin; Martha Hernandez
Journal:  Ophthalmic Physiol Opt       Date:  2014-01-07       Impact factor: 3.117

2.  Prospective evaluation of visual outcomes with three presbyopia-correcting intraocular lenses following cataract surgery.

Authors:  Re Ang; Ga Martinez; Em Cruz; Aa Tiongson; Ag Dela Cruz
Journal:  Clin Ophthalmol       Date:  2013-09-17

3.  Visual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens.

Authors:  Alice T Epitropoulos
Journal:  J Ophthalmol       Date:  2016-01-13       Impact factor: 1.909

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.