Literature DB >> 18783907

An iterative reconstruction technique for geometric distortion-corrected segmented echo-planar imaging.

Yingbiao Xu1, E Mark Haacke.   

Abstract

In this article, we present a modified interleaved segmented echo-planar imaging (SEPI) sequence with a center-out k-space trajectory that is especially designed for susceptibility-weighted imaging applications. We introduce a simple and efficient technique to phase correct the acquired SEPI data in the presence of moderate field inhomogeneities. This phase correction reduces the distortion in the phase-encoding direction without requiring an extra reference scan. With the use of a center-out k-space trajectory and a low-spatial-frequency phase map, phase discontinuities between segments can be eliminated, in principle, iteratively using a fast Fourier transform from the center segment to the outermost segment in k-space. With an extra echo added in front of the echo train, neither phase unwrapping nor an extra reference scan is required to obtain a low-spatial-frequency phase map. The method is shown to remove blurring and reduce geometric distortion caused by phase changes from echo to echo in both phantom and human data. The method is most useful for high-resolution imaging applications and moderate factors of speed improvement.

Entities:  

Mesh:

Year:  2008        PMID: 18783907      PMCID: PMC3763728          DOI: 10.1016/j.mri.2008.04.008

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  14 in total

1.  Reducing oblique flow effects in interleaved EPI with a centric reordering technique.

Authors:  G Beck; D Li; E M Haacke; T G Noll; L R Schad
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Off-resonance correction of MR images.

Authors:  H Schomberg
Journal:  IEEE Trans Med Imaging       Date:  1999-06       Impact factor: 10.048

3.  Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging.

Authors:  J G Pipe
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

4.  Optimized distortion correction technique for echo planar imaging.

Authors:  N K Chen ; A M Wyrwicz
Journal:  Magn Reson Med       Date:  2001-03       Impact factor: 4.668

5.  A model-based method for phase unwrapping.

Authors:  Z P Liang
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

6.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients.

Authors:  D C Noll; C H Meyer; J M Pauly; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

7.  Correction for geometric distortion in echo planar images from B0 field variations.

Authors:  P Jezzard; R S Balaban
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

8.  Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps.

Authors:  P J Reber; E C Wong; R B Buxton; L R Frank
Journal:  Magn Reson Med       Date:  1998-02       Impact factor: 4.668

9.  Reduction of MR imaging time by the hybrid fast-scan technique.

Authors:  E M Haacke; F H Bearden; J R Clayton; N R Linga
Journal:  Radiology       Date:  1986-02       Impact factor: 11.105

10.  Phase errors in multi-shot echo planar imaging.

Authors:  D A Feinberg; K Oshio
Journal:  Magn Reson Med       Date:  1994-10       Impact factor: 4.668

View more
  7 in total

1.  MR venography of the fetal brain using susceptibility weighted imaging.

Authors:  Jaladhar Neelavalli; Swati Mody; Lami Yeo; Pavan Kumar Jella; Steven J Korzeniewski; Sheena Saleem; Yashwanth Katkuri; Ray O Bahado-Singh; Sonia S Hassan; E Mark Haacke; Roberto Romero; Moriah E Thomason
Journal:  J Magn Reson Imaging       Date:  2013-11-25       Impact factor: 4.813

2.  Improved MR venography using quantitative susceptibility-weighted imaging.

Authors:  Saifeng Liu; Karen Mok; Jaladhar Neelavalli; Yu-Chung N Cheng; Jin Tang; Yongquan Ye; E Mark Haacke
Journal:  J Magn Reson Imaging       Date:  2013-10-31       Impact factor: 4.813

3.  Brain iron detected by SWI high pass filtered phase calibrated with synchrotron X-ray fluorescence.

Authors:  Karla Hopp; Bogdan F Gh Popescu; Richard P E McCrea; Sheri L Harder; Christopher A Robinson; Mark E Haacke; Ali H Rajput; Alex Rajput; Helen Nichol
Journal:  J Magn Reson Imaging       Date:  2010-06       Impact factor: 4.813

Review 4.  Susceptibility-weighted imaging: current status and future directions.

Authors:  Saifeng Liu; Sagar Buch; Yongsheng Chen; Hyun-Seok Choi; Yongming Dai; Charbel Habib; Jiani Hu; Joon-Yong Jung; Yu Luo; David Utriainen; Meiyun Wang; Dongmei Wu; Shuang Xia; E Mark Haacke
Journal:  NMR Biomed       Date:  2016-05-18       Impact factor: 4.044

Review 5.  Rapid brain MRI acquisition techniques at ultra-high fields.

Authors:  Kawin Setsompop; David A Feinberg; Jonathan R Polimeni
Journal:  NMR Biomed       Date:  2016-02-02       Impact factor: 4.044

6.  Initial clinical experience with a radiation oncology dedicated open 1.0T MR-simulation.

Authors:  Carri K Glide-Hurst; Ning Wen; David Hearshen; Joshua Kim; Milan Pantelic; Bo Zhao; Tina Mancell; Kenneth Levin; Benjamin Movsas; Indrin J Chetty; M Salim Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

7.  High-resolution structural and functional assessments of cerebral microvasculature using 3D Gas ΔR2*-mMRA.

Authors:  Chien-Hsiang Huang; Chiao-Chi V Chen; Tiing-Yee Siow; Sheng-Hsiou S Hsu; Yi-Hua Hsu; Fu-Shan Jaw; Chen Chang
Journal:  PLoS One       Date:  2013-11-04       Impact factor: 3.240

  7 in total