Literature DB >> 11283990

Reducing oblique flow effects in interleaved EPI with a centric reordering technique.

G Beck1, D Li, E M Haacke, T G Noll, L R Schad.   

Abstract

Segmented interleaved echo planar imaging offers a fast and efficient approach to magnetic resonance angiography. Unfortunately, this technique is particularly sensitive to oblique flow in the imaging plane. In this work, a mathematical analysis of oblique flow effects for several types of k-space coverage is presented. The conventional linear acquisition scheme, an alternating centric and a nonalternating centric encoding scheme are compared with respect to their flow properties. It is shown both by simulations and imaging experiments that artifacts from oblique in-plane flow are effectively reduced by both centric reordered phase-encoding schemes. The nonalternating centric acquisition scheme is preferred to the alternating centric scheme due to the smoother phase error transition in k-space in the presence of obliquely-angled flow. Magn Reson Med 45:623-629, 2001. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11283990     DOI: 10.1002/mrm.1084

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  High temporal resolution phase contrast MRI with multiecho acquisitions.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

2.  The Importance of k-Space Trajectory on Off-Resonance Artifact in Segmented Echo-Planar Imaging.

Authors:  Jacob A Bender; Rizwan Ahmad; Orlando P Simonetti
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2013-03-01       Impact factor: 0.481

3.  Accelerating time-resolved MRA with multiecho acquisition.

Authors:  Hyun J Jeong; Christopher S Eddleman; Saurabh Shah; Nicole Seiberlich; Mark A Griswold; H Hunt Batjer; James C Carr; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

4.  An iterative reconstruction technique for geometric distortion-corrected segmented echo-planar imaging.

Authors:  Yingbiao Xu; E Mark Haacke
Journal:  Magn Reson Imaging       Date:  2008-09-09       Impact factor: 2.546

5.  Free-breathing myocardial T2* mapping using GRE-EPI and automatic non-rigid motion correction.

Authors:  Ning Jin; Juliana Serafim da Silveira; Marie-Pierre Jolly; David N Firmin; George Mathew; Nathan Lamba; Sharath Subramanian; Dudley J Pennell; Subha V Raman; Orlando P Simonetti
Journal:  J Cardiovasc Magn Reson       Date:  2015-12-23       Impact factor: 5.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.