Literature DB >> 18781342

Assessment of different screw augmentation techniques and screw designs in osteoporotic spines.

S Becker1, A Chavanne, R Spitaler, K Kropik, N Aigner, M Ogon, H Redl.   

Abstract

This is an experimental study on human cadaver spines. The objective of this study is to compare the pullout forces between three screw augmentation methods and two different screw designs. Surgical interventions of patients with osteoporosis increase following the epidemiological development. Biomechanically the pedicle provides the strongest screw fixation in healthy bone, whereas in osteoporosis all areas of the vertebra are affected by the disease. This explains the high screw failure rates in those patients. Therefore PMMA augmentation of screws is often mandatory. This study involved investigation of the pullout forces of augmented transpedicular screws in five human lumbar spines (L1-L4). Each spine was treated with four different methods: non-augmented unperforated (solid) screw, perforated screw with vertebroplasty augmentation, solid screw with vertebroplasty augmentation and solid screw with balloon kyphoplasty augmentation. Screws were augmented with Polymethylmethacrylate (PMMA). The pullout forces were measured for each treatment with an Instron testing device. The bone mineral density was measured for each vertebra with Micro-CT. The statistical analysis was performed with a two-sided independent student t test. Forty screws (10 per group and level) were inserted. The vertebroplasty-augmented screws showed a significant higher pullout force (mean 918.5 N, P = 0.001) than control (mean 51 N), the balloon kyphoplasty group did not improve the pullout force significantly (mean 781 N, P > 0.05). However, leakage occurred in some cases treated with perforated screws. All spines showed osteoporosis on Micro-CT. Vertebroplasty-augmented screws, augmentation of perforated screws and balloon kyphoplasty augmented screws show higher pullout resistance than non-augmented screws. Significant higher pullout forces were only reached in the vertebroplasty augmented vertebra. The perforated screw design led to epidural leakage due to the position of the perforation in the screw. The position of the most proximal perforation is critical, depending on screw design and proper insertion depth. Nevertheless, using a properly designed perforated screw will facilitate augmentation and instrumentation in osteoporotic spines.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18781342      PMCID: PMC2583182          DOI: 10.1007/s00586-008-0769-8

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  40 in total

1.  Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65: surgical considerations and treatment options in patients with poor bone quality.

Authors:  Christopher J DeWald; Thomas Stanley
Journal:  Spine (Phila Pa 1976)       Date:  2006-09-01       Impact factor: 3.468

2.  Stability of pedicle screws after kyphoplasty augmentation: an experimental study to compare transpedicular screw fixation in soft and cured kyphoplasty cement.

Authors:  Oliver Linhardt; Christian Lüring; Jan Matussek; Corinna Hamberger; Wolfgang Plitz; Joachim Grifka
Journal:  J Spinal Disord Tech       Date:  2006-04

3.  Stability of anterior vertebral body screws after kyphoplasty augmentation. An experimental study to compare anterior vertebral body screw fixation in soft and cured kyphoplasty cement.

Authors:  O Linhardt; C Lüring; J Matussek; C Hamberger; T Herold; W Plitz; J Grifka
Journal:  Int Orthop       Date:  2006-04-04       Impact factor: 3.075

4.  Cement augmentation of vertebral screws enhances the interface strength between interbody device and vertebral body.

Authors:  Juay-Seng Tan; Christopher S Bailey; Marcel F Dvorak; Charles G Fisher; Peter A Cripton; Thomas R Oxland
Journal:  Spine (Phila Pa 1976)       Date:  2007-02-01       Impact factor: 3.468

5.  Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization.

Authors:  Constantin Schizas; Jacky Michel; Victor Kosmopoulos; Nicolas Theumann
Journal:  Eur Spine J       Date:  2006-09-12       Impact factor: 3.134

6.  Structural characteristics of the pedicle and its role in screw stability.

Authors:  T Hirano; K Hasegawa; H E Takahashi; S Uchiyama; T Hara; T Washio; T Sugiura; M Yokaichiya; M Ikeda
Journal:  Spine (Phila Pa 1976)       Date:  1997-11-01       Impact factor: 3.468

Review 7.  Internal fixation in the osteoporotic spine.

Authors:  S S Hu
Journal:  Spine (Phila Pa 1976)       Date:  1997-12-15       Impact factor: 3.468

8.  Prospective study of standalone balloon kyphoplasty with calcium phosphate cement augmentation in traumatic fractures.

Authors:  Gianluca Maestretti; Claus Cremer; Philippe Otten; Roland Peter Jakob
Journal:  Eur Spine J       Date:  2006-11-22       Impact factor: 3.134

Review 9.  Balloon kyphoplasty and vertebroplasty for vertebral compression fractures: a comparative systematic review of efficacy and safety.

Authors:  Rod S Taylor; Rebecca J Taylor; Peter Fritzell
Journal:  Spine (Phila Pa 1976)       Date:  2006-11-01       Impact factor: 3.468

10.  Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength.

Authors:  Daniel J Burval; Robert F McLain; Ryan Milks; Serkan Inceoglu
Journal:  Spine (Phila Pa 1976)       Date:  2007-05-01       Impact factor: 3.468

View more
  60 in total

1.  [Traumatic vertebral body fractures and osteoporosis: value of cement augmentation].

Authors:  H Laurer; A Sander; S Wutzler; C Nau; I Marzi
Journal:  Orthopade       Date:  2010-07       Impact factor: 1.087

2.  [Cement distribution in vertebroplasty pedicle screws with different designs].

Authors:  K Kafchitsas; F Geiger; M Rauschmann; S Schmidt
Journal:  Orthopade       Date:  2010-07       Impact factor: 1.087

Review 3.  [Modern implant design for the osteosynthesis of osteoporotic bone fractures].

Authors:  P Augat; V Bühren
Journal:  Orthopade       Date:  2010-04       Impact factor: 1.087

4.  Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling.

Authors:  Lih-Huei Chen; Ching-Lung Tai; De-Mei Lee; Po-Liang Lai; Yen-Chen Lee; Chi-Chien Niu; Wen-Jer Chen
Journal:  BMC Musculoskelet Disord       Date:  2011-02-01       Impact factor: 2.362

Review 5.  [Stabilization of the osteoporotic spine from a biomechanical viewpoint].

Authors:  C-E Heyde; A Rohlmann; U Weber; R Kayser
Journal:  Orthopade       Date:  2010-04       Impact factor: 1.087

6.  Diagnosis and planning in the management of musculoskeletal tumors: surgical perspective.

Authors:  Onder Ofluoglu; Stefano Boriani; Alessandro Gasbarrini; Federico De Iure; Rakesh Donthineni
Journal:  Semin Intervent Radiol       Date:  2010-06       Impact factor: 1.513

7.  Evaluation of the in vitro cell-material interactions and in vivo osteo-integration of a spinal acrylic bone cement.

Authors:  Sophie Verrier; Lisa Hughes; Antoine Alves; Marianna Peroglio; Mauro Alini; Andreas Boger
Journal:  Eur Spine J       Date:  2011-08-03       Impact factor: 3.134

8.  Effect of augmentation techniques on the failure of pedicle screws under cranio-caudal cyclic loading.

Authors:  Richard Bostelmann; Alexander Keiler; Hans Jakob Steiger; Armin Scholz; Jan Frederick Cornelius; Werner Schmoelz
Journal:  Eur Spine J       Date:  2015-03-27       Impact factor: 3.134

9.  A pedicle screw system and a lamina hook system provide similar primary and long-term stability: a biomechanical in vitro study with quasi-static and dynamic loading conditions.

Authors:  Hans-Joachim Wilke; Dominik Kaiser; David Volkheimer; Carsten Hackenbroch; Klaus Püschel; Michael Rauschmann
Journal:  Eur Spine J       Date:  2016-07-12       Impact factor: 3.134

10.  [Hounsfield units as a measure of bone density-applications in spine surgery].

Authors:  Max J Scheyerer; Bernhard Ullrich; Georg Osterhoff; Ulrich A Spiegl; Klaus J Schnake
Journal:  Unfallchirurg       Date:  2019-08       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.