Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization.

Constantin Schizas1, Jacky Michel, Victor Kosmopoulos, Nicolas Theumann.   

Abstract

Percutaneous insertion of cannulated pedicle screws has been recently developed as a minimally invasive alternative to the open technique during instrumented fusion procedures. Given the reported rate of screw misplacement using open techniques (up to 40%), we considered it important to analyze possible side effects of this new technique. Placement of 60 pedicle screws in 15 consecutive patients undergoing lumbar or lumbosacral fusion, mainly for spondylolisthesis, were analyzed. Axial, coronal, and sagittal reformatted computer tomography images were examined by three observers. Individual and consensus interpretation was obtained for each screw position. Along with frank penetration, we also looked at cortical encroachment of the pedicular wall by the screw. Thirteen percent of the patients (2/15) had severe frank penetration from the screws, while 80% of them (12/15) had some perforation. On axial images the incidence of severe frank pedicle penetration was 3.3% while the overall rate of screw perforation was 23%. In coronal images the overall screw perforation rate rose to 30% while the rate of severe frank pedicle penetration remained unchanged. One patient (6.6%) suffered S1 root symptoms due to a frankly medially misplaced screw, requiring re-operation. This study has shown that percutaneous insertion of cannulated pedicle screws in the lumbar spine is an acceptable procedure. The overall rate of perforation in axial images is below the higher rates reported in the literature but does remain important. Frank penetration of the pedicle was nevertheless low. It remains a demanding technique and has to be performed with extreme care to detail.

Entities:  

Mesh:

Year:  2006        PMID: 16967297      PMCID: PMC2213548          DOI: 10.1007/s00586-006-0221-x

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  18 in total

1.  Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine.

Authors:  L Wiesner; R Kothe; K P Schulitz; W Rüther
Journal:  Spine (Phila Pa 1976)       Date:  2000-03-01       Impact factor: 3.468

2.  Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients.

Authors:  T Laine; T Lund; M Ylikoski; J Lohikoski; D Schlenzka
Journal:  Eur Spine J       Date:  2000-06       Impact factor: 3.134

3.  Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note.

Authors:  Langston T Holly; Kevin T Foley
Journal:  J Neurosurg       Date:  2003-10       Impact factor: 5.115

4.  Minimally invasive percutaneous posterior lumbar interbody fusion.

Authors:  Larry T Khoo; Sylvain Palmer; Daniel T Laich; Richard G Fessler
Journal:  Neurosurgery       Date:  2002-11       Impact factor: 4.654

5.  Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation.

Authors:  Thomas J Learch; Jennifer B Massie; Mini N Pathria; Bradley A Ahlgren; Steven R Garfin
Journal:  Spine (Phila Pa 1976)       Date:  2004-04-01       Impact factor: 3.468

6.  Accuracy of pedicular screw placement in vivo.

Authors:  S D Gertzbein; S E Robbins
Journal:  Spine (Phila Pa 1976)       Date:  1990-01       Impact factor: 3.468

7.  Stabilization of the lower thoracic and lumbar spine with external skeletal fixation.

Authors:  F P Magerl
Journal:  Clin Orthop Relat Res       Date:  1984-10       Impact factor: 4.176

8.  Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography.

Authors:  G L Farber; H M Place; R A Mazur; D E Jones; T R Damiano
Journal:  Spine (Phila Pa 1976)       Date:  1995-07-01       Impact factor: 3.468

9.  The role of external spinal skeletal fixation in the assessment of low-back disorders.

Authors:  S I Esses; D J Botsford; J P Kostuik
Journal:  Spine (Phila Pa 1976)       Date:  1989-06       Impact factor: 3.468

10.  Internal fixation of the lumbar spine with pedicle screw plating.

Authors:  R Roy-Camille; G Saillant; C Mazel
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

View more
  40 in total

1.  CT accuracy of percutaneous versus open pedicle screw techniques: a series of 1609 screws.

Authors:  Todd M Chapman; Daniel J Blizzard; Christopher R Brown
Journal:  Eur Spine J       Date:  2015-07-29       Impact factor: 3.134

2.  A comparison of feasibility and safety of percutaneous fluoroscopic guided thoracic pedicle screws between Europeans and Asians: is there any difference?

Authors:  Mun Keong Kwan; Chee Kidd Chiu; Chris Yin Wei Chan; Reza Zamani; Nils Hansen-Algenstaedt
Journal:  Eur Spine J       Date:  2015-07-30       Impact factor: 3.134

3.  Fluoroscopy-guided pedicle screw accuracy with a mini-open approach: a tomographic evaluation of 470 screws in 125 patients.

Authors:  José Antonio Soriano-Sánchez; Luis Alberto Ortega-Porcayo; Carlos Francisco Gutiérrez-Partida; Luis Rodolfo Ramírez-Barrios; Ramses Uriel Ortíz-Leyva; Manuel Rodríguez-García; Oscar Sánchez-Escandón
Journal:  Int J Spine Surg       Date:  2015-10-23

4.  Monitoring reduced scattering coefficient in pedicle screw insertion trajectory using near-infrared spectroscopy.

Authors:  Weitao Li; Yangyang Liu; Haixiang Sun; Yue Pan; Zhiyu Qian
Journal:  Med Biol Eng Comput       Date:  2015-12-22       Impact factor: 2.602

Review 5.  Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review.

Authors:  Hani J Marcus; Thomas P Cundy; Dipankar Nandi; Guang-Zhong Yang; Ara Darzi
Journal:  Eur Spine J       Date:  2013-06-26       Impact factor: 3.134

6.  Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures.

Authors:  Markus Beck; Thomas Mittlmeier; Philip Gierer; Christoph Harms; Georg Gradl
Journal:  Eur Spine J       Date:  2009-06-10       Impact factor: 3.134

7.  Factors affecting the accurate placement of percutaneous pedicle screws during minimally invasive transforaminal lumbar interbody fusion.

Authors:  Moon-Chan Kim; Hung-Tae Chung; Jae-Lim Cho; Dong-Jun Kim; Nam-Su Chung
Journal:  Eur Spine J       Date:  2011-07-01       Impact factor: 3.134

Review 8.  The evolution of image-guided lumbosacral spine surgery.

Authors:  Austin C Bourgeois; Austin R Faulkner; Alexander S Pasciak; Yong C Bradley
Journal:  Ann Transl Med       Date:  2015-04

9.  Assessment of different screw augmentation techniques and screw designs in osteoporotic spines.

Authors:  S Becker; A Chavanne; R Spitaler; K Kropik; N Aigner; M Ogon; H Redl
Journal:  Eur Spine J       Date:  2008-09-10       Impact factor: 3.134

10.  Comparison of minimally invasive fusion and instrumentation versus open surgery for severe stenotic spondylolisthesis with high-grade facet joint osteoarthritis.

Authors:  Eleftherios Archavlis; Mario Carvi y Nievas
Journal:  Eur Spine J       Date:  2013-03-12       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.