Literature DB >> 18780084

Biomechanical comparison of different volar fracture fixation plates for distal radius fractures.

Kareem Sobky1, Todd Baldini, Kenneth Thomas, Joel Bach, Allison Williams, Jennifer Moriatis Wolf.   

Abstract

The purpose of this study was to compare the biomechanical properties of four volar fixed-angle fracture fixation plate designs in a novel sawbones model as well as in cadavers. Four volar fixed angle plating systems (Hand Innovations DVR-A, Avanta SCS/V, Wright Medical Lo-Con VLS, and Synthes stainless volar locking) were tested on sawbones models using an osteotomy gap model to simulate a distal radius fracture. Based on a power analysis, six plates from each system were tested to failure in axial compression. To simulate loads with physiologic wrist motion, six plates of each type were then tested to failure following 10,000 cycles applying 100N of compression. To compare plate failure behavior, two plates of each type were implanted in cadaver wrists and similar testing applied. All plate constructs were loaded to failure. All failed with in apex volar angulation. The Hand Innovations DVR-A plate demonstrated significantly more strength in peak load to failure and failure after fatigue cycling (p value < 0.001 for single load and fatigue failure). However, there was no significant difference in stiffness among the four plates in synthetic bone. The cadaveric model demonstrated the same mode of failure as the sawbones. None of the volar plates demonstrated screw breakage or pullout, except the tine plate (Avanta SCS/V) with 1 mm of pullout in 2 of 12 plates. This study demonstrates the utility of sawbones in biomechanical testing and indicates that volar fixation of unstable distal radius fractures with a fixed angle device is a reliable means of stabilization.

Entities:  

Year:  2007        PMID: 18780084      PMCID: PMC2529136          DOI: 10.1007/s11552-007-9074-y

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  28 in total

1.  Biomechanical evaluation of the modified double-plating fixation for the distal radius fracture.

Authors:  Hsin-Yi Kathy Cheng; Chun-Li Lin; Yu-Hao Lin; Alvin Chao-Yu Chen
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-02-27       Impact factor: 2.063

2.  Treatment of displaced intra-articular fractures of the distal end of the radius with plates.

Authors:  F Fitoussi; W Y Ip; S P Chow
Journal:  J Bone Joint Surg Am       Date:  1997-09       Impact factor: 5.284

3.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

4.  Effect on force transmission across the carpus in procedures used to treat Kienböck's disease.

Authors:  E Horii; M Garcia-Elias; A T Bishop; W P Cooney; R L Linscheid; E Y Chao
Journal:  J Hand Surg Am       Date:  1990-05       Impact factor: 2.230

5.  [Unstable fracture of the distal radius and its treatment: comparison of three techniques: external fixation, intramedullary pinning and AO plates].

Authors:  G R Sennwald; D Della Santa
Journal:  Chir Main       Date:  2001-06

6.  Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures.

Authors:  D Ring; J B Jupiter; J Brennwald; U Büchler; H Hastings
Journal:  J Hand Surg Am       Date:  1997-09       Impact factor: 2.230

7.  Augmented external fixation of distal radius fractures: a biomechanical analysis.

Authors:  S W Wolfe; C R Swigart; J Grauer; J F Slade; M M Panjabi
Journal:  J Hand Surg Am       Date:  1998-01       Impact factor: 2.230

8.  Biomechanics in uniaxial compression of three distal radius volar plates.

Authors:  Denju Osada; Satoshi Fujita; Kazuya Tamai; Akira Iwamoto; Kazuo Tomizawa; Koichi Saotome
Journal:  J Hand Surg Am       Date:  2004-05       Impact factor: 2.230

9.  Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures.

Authors:  Peter P Chiang; Stephanie Roach; Mark E Baratz
Journal:  J Hand Surg Am       Date:  2002-07       Impact factor: 2.230

10.  Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study.

Authors:  Denju Osada; Steven F Viegas; Munir A Shah; Randal P Morris; Rita M Patterson
Journal:  J Hand Surg Am       Date:  2003-01       Impact factor: 2.230

View more
  7 in total

1.  Functional Outcome and Complications at 2.5 Years Following Volar Locking Plate Fixation of Distal Radius Fractures.

Authors:  Robert J MacFarlane; David Miller; Lynn Wilson; Carl Meyer; Cronan Kerin; David James Ford; Graham Cheung
Journal:  J Hand Microsurg       Date:  2015-01-27

2.  The results of volar locking plate fixation for the fragility fracture population with distal radius fracture in Japanese women.

Authors:  Shuichi Kato; Masahiro Tatebe; Michiro Yamamoto; Katsuyuki Iwatsuki; Takanobu Nishizuka; Hitoshi Hirata
Journal:  Nagoya J Med Sci       Date:  2014-02       Impact factor: 1.131

3.  Author's reply.

Authors:  Sharad M Hardikar; Srinivas Prakash; Madan S Hardikar; Rohit Kumar
Journal:  Indian J Orthop       Date:  2016 Mar-Apr       Impact factor: 1.251

4.  Does the DVR(®) plate restore bony anatomy following distal radius fractures?

Authors:  S Patel; P B Menéndez; F S Hossain; H B Colaço; M H Lee; E D Sorene; E J Taylor
Journal:  Ann R Coll Surg Engl       Date:  2014-01       Impact factor: 1.891

5.  Two peg spade plate for distal radius fractures: A novel technique.

Authors:  Sharad M Hardikar; Sreenivas Prakash; Madan S Hardikar; Rohit Kumar
Journal:  Indian J Orthop       Date:  2015 Sep-Oct       Impact factor: 1.251

6.  STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS.

Authors:  Daniel Gonçalves Machado; Sergio Auto da Cruz Cerqueira; Rodrigo Ribeiro Pinho Rodarte; Carlos Alberto de Souza Araújo Netto; Marcelo Bezerra de Mathias
Journal:  Rev Bras Ortop       Date:  2015-12-06

7.  The Comparison of Biomechanical Volar and Dorsal Plating in Distal Part Radius Fractures; a Finite Element Analysis Study.

Authors:  Ali Ghaem-Maghami; Ehsan Fallah; Hamid Namazi; Mohammad-Taghi Karimi; Seyed Iman Hosseini
Journal:  Bull Emerg Trauma       Date:  2021-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.