Literature DB >> 9523966

Augmented external fixation of distal radius fractures: a biomechanical analysis.

S W Wolfe1, C R Swigart, J Grauer, J F Slade, M M Panjabi.   

Abstract

An in vitro model of an unstable extra-articular distal radius fracture was created in 8 fresh-frozen cadaveric specimens and stabilized with an external fixator. Rotation and translation kinematics of the distal radial fracture fragment were measured in relation to the proximal radius during physiologic loading, using infrared light-emitting diodes and a 3-dimensional motion-sensing device. The effect of supplemental single and combination Kirschner wire (K-wire) fixation on fracture fragment stability was assessed. Fixation of supplemental K-wires to the fixator frame via a custom-developed outrigger assembly was also analyzed. Significant reductions in sagittal plane (flexion/extension) rotation and neutral zone were recorded when the fracture fragment was stabilized with a single styloid or dorsal transfixion K-wire. Equivalent stability was afforded by attachment of a nontransfixion K-wire to the fixator frame via the outrigger assembly. The dorsal constructs compared favorably to the styloid constructs in reduction of the sagittal plane neutral zone and coronal (radioulnar) rotation. These data lend biomechanical support to the concept of augmentation of distal radius external fixation and provide a physiologic model to test fixation methods for other fracture patterns.

Entities:  

Mesh:

Year:  1998        PMID: 9523966     DOI: 10.1016/S0363-5023(98)80100-7

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  13 in total

1.  The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.

Authors:  Lindley B Wall; Michael D Brodt; Matthew J Silva; Martin I Boyer; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2012-02-02       Impact factor: 2.230

2.  Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study.

Authors:  Chun-Li Lin; Yu-Hao Lin; Alvin Chao-Yu Chen
Journal:  Med Biol Eng Comput       Date:  2006-07-11       Impact factor: 2.602

3.  Volar fixation of distal radial fracture using compression plate: clinical and radiographic evaluation of 20 patients.

Authors:  S Giannotti; P Alfieri; L Magistrelli; F Casella; L Palmeri; G Guido
Journal:  Musculoskelet Surg       Date:  2012-12-30

4.  The use of beta-tricalcium phosphate bone graft substitute in dorsally plated, comminuted distal radius fractures.

Authors:  Michael G Jakubietz; Joerg G Gruenert; Rafael G Jakubietz
Journal:  J Orthop Surg Res       Date:  2011-05-22       Impact factor: 2.359

5.  Volar long locking compression plate fixation for distal radius fractures with metaphyseal and diaphyseal extension.

Authors:  Sang Ki Lee; Dong Wook Seo; Kap Jung Kim; Dae Suk Yang; Won Sik Choy
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-04-19

6.  Biomechanical performance of variable and fixed angle locked volar plates for the dorsally comminuted distal radius.

Authors:  D Martineau; J Shorez; C Beran; A G Dass; P Atkinson
Journal:  Iowa Orthop J       Date:  2014

7.  External fixation with or without supplementary intramedullary Kirschner wires in the treatment of distal radial fractures.

Authors:  Charles Lin; Jui-Sheng Sun; Sheng-Mou Hou
Journal:  Can J Surg       Date:  2004-12       Impact factor: 2.089

8.  Appropriately Matched Fixed-Angle Locking Plates Improve Stability in Volar Distal Radius Fixation.

Authors:  Natalia D McIver; Christina Salas; Nathan Menon; John Heifner; Deana Mercer
Journal:  J Hand Surg Glob Online       Date:  2022-04-04

9.  [Design of distal radius volar locking plates : Anatomical, surgical and biomechanical aspects].

Authors:  M Wich; R Sixto; N Spranger
Journal:  Unfallchirurg       Date:  2016-09       Impact factor: 1.000

10.  Biomechanical comparison of different volar fracture fixation plates for distal radius fractures.

Authors:  Kareem Sobky; Todd Baldini; Kenneth Thomas; Joel Bach; Allison Williams; Jennifer Moriatis Wolf
Journal:  Hand (N Y)       Date:  2007-09-07
View more