Literature DB >> 26078498

Functional Outcome and Complications at 2.5 Years Following Volar Locking Plate Fixation of Distal Radius Fractures.

Robert J MacFarlane1, David Miller2, Lynn Wilson3, Carl Meyer3, Cronan Kerin3, David James Ford3, Graham Cheung4.   

Abstract

Distal radius fractures are increasingly treated by internal fixation, but there have been relatively few studies relating to functional outcome at 12 months or more. The aim of this study was to ascertain the patient reported function of the wrist at a minimum of 12 months following fixation of a distal radius fracture, the time taken to return to work, and the complication rate. We conducted a retrospective review of 187 consecutive patients treated by a specialist hand and wrist trauma team at a tertiary referral unit over a 5 year period. Mean age was 57.3 years (range 16-93). Median time to surgery was 4 days (interquartile range 2-9). Median follow up was 31 months (interquartile range 23-41 months). The median PRWE score was 3; (range 0-83). There was no difference in outcome in patients who had surgery delayed by greater than 2 weeks (p > 0.05). The median time to return to work was 5 weeks (interquartile range 1-8 weeks). There were 15 complications (8 %) including 3 tendon injuries. We have demonstrated an early return to work in patients who were employed, a low complication rate, and highly favourable functional outcomes at a mean of 30 months postoperatively. We recommend the use of the DVR plate and involvement of a dedicated hand and wrist trauma team for treatment of unstable fractures of the distal radius.

Entities:  

Keywords:  Distal radius fracture; Locking plate; Outcome measure; PRWE

Year:  2015        PMID: 26078498      PMCID: PMC4461642          DOI: 10.1007/s12593-014-0155-1

Source DB:  PubMed          Journal:  J Hand Microsurg        ISSN: 0974-3227


  34 in total

Review 1.  Dynamic versus static external fixation for unstable distal radius fractures: an up-to-date meta-analysis.

Authors:  Zhuang Cui; Bin Yu; Yanjun Hu; Qingrong Lin; Bowei Wang
Journal:  Injury       Date:  2011-12-16       Impact factor: 2.586

2.  How placement affects force and contact pressure between a volar plate of the distal radius and the flexor pollicus longus tendon: a biomechanical investigation.

Authors:  A M Matityahu; S N Lapalme; A Seth; M T Marmor; J M Buckley; L L Lattanza
Journal:  J Hand Surg Eur Vol       Date:  2012-07-09

3.  The extended flexor carpi radialis approach: a new perspective for the distal radius fracture.

Authors:  J L Orbay; A Badia; I R Indriago; A Infante; R K Khouri; E Gonzalez; D L Fernandez
Journal:  Tech Hand Up Extrem Surg       Date:  2001-12

Review 4.  Percutaneous pinning for treating distal radial fractures in adults.

Authors:  H H G Handoll; M V Vaghela; R Madhok
Journal:  Cochrane Database Syst Rev       Date:  2007-07-18

5.  Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures.

Authors:  M Al-Rashid; K Theivendran; M A C Craigen
Journal:  J Bone Joint Surg Br       Date:  2006-12

6.  Bridging and non-bridging external fixation in the treatment of unstable fractures of the distal radius: a retrospective study of 588 patients.

Authors:  Alison J Hayes; Paul J Duffy; Margaret M McQueen
Journal:  Acta Orthop       Date:  2008-08       Impact factor: 3.717

7.  Extensor pollicis longus rupture at the tip of a prominent fixation screw: report of three cases.

Authors:  J M Failla; M P Koniuch; B R Moed
Journal:  J Hand Surg Am       Date:  1993-07       Impact factor: 2.230

8.  Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.

Authors:  Eric J Strauss; Devraj Banerjee; Frederick J Kummer; Nirmal C Tejwani
Journal:  J Trauma       Date:  2008-04

9.  Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results.

Authors:  Markus Figl; Patrick Weninger; Michael Liska; Marcus Hofbauer; Martin Leixnering
Journal:  Arch Orthop Trauma Surg       Date:  2009-02-19       Impact factor: 3.067

10.  Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

View more
  6 in total

1.  Treatment of Distal Radial Fractures by Open Reduction and Internal Fixation with a Volar Locking Plate.

Authors:  Nathan S Mauser; Michel Y Benoit; Nathan T Morrell; Adam B Shafritz
Journal:  JBJS Essent Surg Tech       Date:  2016-09-14

Review 2.  Distal radius fractures in the athlete.

Authors:  Casey Beleckas; Ryan Calfee
Journal:  Curr Rev Musculoskelet Med       Date:  2017-03

3.  Intramedullary Fixation of Distal Radius Fractures Using CAGE-DR Implant.

Authors:  Schneider K Rancy; Stephanie D Malliaris; Eric A Bogner; Scott W Wolfe
Journal:  J Wrist Surg       Date:  2018-09-18

4.  Return to Yoga Rates Are High After Volar Plating of Distal Radius Fractures.

Authors:  Nitin Goyal; Andrew G Tsai; Jefferson Li; Robert W Wysocki
Journal:  Hand (N Y)       Date:  2019-05-23

5.  Two peg spade plate for distal radius fractures: A novel technique.

Authors:  Darshan Kumar A Jain
Journal:  Indian J Orthop       Date:  2016 Mar-Apr       Impact factor: 1.251

6.  Long-term subjective results and radiologic prognosis of a distal radius fracture in working-aged patients - a prognostic cohort study of 201 patients.

Authors:  Teemu P Hevonkorpi; Lauri Raittio; Susanna Vähä-Tuisku; Antti P Launonen; Ville M Mattila
Journal:  J Int Med Res       Date:  2021-12       Impact factor: 1.671

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.