A novel MR-guided interventional device for 3D circumferential access to breast tissue.

Matthew Smith1, Xu Zhai, Ray Harter, Gale Sisney, Mai Elezabye, Sean Fain.   

Abstract

MRI is rapidly growing as a tool for image-guided procedures in the breast such as needle localizations, biopsy, and cryotherapy. The ability of MRI to resolve small (<1 cm) lesions allows earlier detection and diagnosis than with ultrasound. Most MR-guidance methods perform a two-dimensional compression of the breast that distorts tissue anatomy and limits medial access. This work presents a system for localizing breast lesions with 360 degrees access to breast tissue. A novel system has been developed to perform breast lesion localization using MR guidance that uses a 3D radial coordinate system with four degrees of freedom. The device is combined with a novel breast RF coil for improved signal to noise and rotates 360 degrees around the breast to allow medial, lateral, superior, and inferior access minimizing insertion depth to the target. Coil performance was evaluated using a human volunteer by comparing signal to noise from both the developed breast RF coil and a commercial seven-channel breast coil. The system was tested with a breast-shaped gel phantom containing randomly distributed MR-visible targets. MR-compatible localization needles were used to demonstrate the accuracy and feasibility of the concept for breast biopsy. Localization results were classified based on the relationship between the final needle tip position and the lesion. A 3D bladder concept was also tested using animal tissue to evaluate the device's ability to immobilize deformable breast tissue during a needle insertion. The RF breast coil provided signal to noise values comparable to a seven-channel breast coil. The needle tip was in contact with the targeted lesion in 89% (25/28) of all the trials and 100% (6/6) of the trials with targeted lesions >6 mm. Target lesions were 3-4 mm in diameter for 47% (13/28), 5-6 mm in diameter for 32% (9/28), and over 6 mm in diameter for 21% (6/28) of the trials, respectively. The 3D bladder concept was shown to immobilize a deformable animal tissue phantom during needle insertion. It is concluded that the MR-guidance system accurately localizes small targets on the order of 3-4 mm in a breast phantom with 360 degrees rotational access.

Entities:  

Mesh:

Year:  2008        PMID: 18777937      PMCID: PMC2673646          DOI: 10.1118/1.2952442

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

Review 1.  Interventional MRI of the breast: lesion localisation and biopsy.

Authors:  S H Heywang-Köbrunner; A Heinig; D Pickuth; T Alberich; R P Spielmann
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

2.  An apparatus for MR-guided breast lesion localization and core biopsy: design and preliminary results.

Authors:  E Schneider; K W Rohling; M D Schnall; R O Giaquinto; E A Morris; D Ballon
Journal:  J Magn Reson Imaging       Date:  2001-09       Impact factor: 4.813

3.  European quadricentric evaluation of a breast MR biopsy and localization device: technical improvements based on phase-I evaluation.

Authors:  X Prat; H Sittek; A Grosse; L Baath; C Perlet; T Alberich; J M Lamarque; I Andersson; M Reiser; P Taourel; H Fischer; S H Heywang-Köbrunner
Journal:  Eur Radiol       Date:  2002-03-23       Impact factor: 5.315

4.  Imaging histologic discordance at MRI-guided 9-gauge vacuum-assisted breast biopsy.

Authors:  Jung-Min Lee; Jennifer B Kaplan; Melissa P Murray; Lia Bartella; Elizabeth A Morris; Sandra Joo; D David Dershaw; Laura Liberman
Journal:  AJR Am J Roentgenol       Date:  2007-10       Impact factor: 3.959

5.  Large-core needle biopsy of nonpalpable breast lesions.

Authors:  J E Meyer; D N Smith; S C Lester; C Kaelin; P J DiPiro; C M Denison; R L Christian; S C Harvey; D L Selland; S M Durfee
Journal:  JAMA       Date:  1999-05-05       Impact factor: 56.272

6.  Preoperative MR imaging-guided needle localization of breast lesions.

Authors:  Elizabeth A Morris; Laura Liberman; D David Dershaw; Jennifer B Kaplan; Linda R LaTrenta; Andrea F Abramson; Douglas J Ballon
Journal:  AJR Am J Roentgenol       Date:  2002-05       Impact factor: 3.959

7.  Percutaneous large-core breast biopsy: a multi-institutional study.

Authors:  S H Parker; F Burbank; R J Jackman; C J Aucreman; G Cardenosa; T M Cink; J L Coscia; G W Eklund; W P Evans; P R Garver
Journal:  Radiology       Date:  1994-11       Impact factor: 11.105

8.  Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast.

Authors:  Liane E Philpotts; Regina J Hooley; Carol H Lee
Journal:  AJR Am J Roentgenol       Date:  2003-02       Impact factor: 3.959

9.  Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast.

Authors:  Blake T Larson; Arthur G Erdman; Nikolaos V Tsekos; Essa Yacoub; Panagiotis V Tsekos; Ioannis G Koutlas
Journal:  J Biomech Eng       Date:  2004-08       Impact factor: 2.097

10.  Diagnostic accuracy for different strategies of image-guided breast intervention in cases of nonpalpable breast lesions.

Authors:  R M Pijnappel; M van den Donk; R Holland; W P Th M Mali; J L Peterse; J H C L Hendriks; P H M Peeters
Journal:  Br J Cancer       Date:  2004-02-09       Impact factor: 7.640

View more
  1 in total

1.  A magnetic resonance image-guided breast needle intervention robot system: overview and design considerations.

Authors:  Samuel Byeongjun Park; Jung-Gun Kim; Ki-Woong Lim; Chae-Hyun Yoon; Dong-Jun Kim; Han-Sung Kang; Yung-Ho Jo
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-06       Impact factor: 2.924

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.