Literature DB >> 12111063

European quadricentric evaluation of a breast MR biopsy and localization device: technical improvements based on phase-I evaluation.

X Prat1, H Sittek, A Grosse, L Baath, C Perlet, T Alberich, J M Lamarque, I Andersson, M Reiser, P Taourel, H Fischer, S H Heywang-Köbrunner.   

Abstract

Our purpose was to report about technical success, problems and solutions, as experienced in a first multicentre study on MR-guided localisation or vacuum biopsy of breast lesions. The study was carried out at four European sites using a dedicated prototype breast biopsy device. Experiences with 49 scheduled localisation procedures and 188 vacuum biopsies are reported. Apart from 35 dropped indications, one localisation procedure and 9 vacuum biopsies were not possible (3 times space problems due to obesity, 2 times too strong compression, 3 times impaired access from medially, 2 times impaired access due to a metal bar). Problems due to too strong compression were recognised by repeat MR without compression. During the procedure problems leading to an uncertain result occurred in eight vacuum biopsies, two related to the procedure: one limited access, and one strong post-biopsy enhancement. Improvements after phase-I study concerned removal of the metal bar, development of an improved medial access, of a profile imitating the biopsy gun, optimisation of compression plates and improved software support. The partners agreed that the improvements answered all important technical problems.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12111063     DOI: 10.1007/s00330-002-1317-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  6 in total

1.  Magnetic resonance-guided vacuum-assisted breast biopsy: results in 100 Japanese women.

Authors:  Mitsuhiro Tozaki; Norie Yamashiro; Masaaki Sakamoto; Naomi Sakamoto; Nobuo Mizuuchi; Eisuke Fukuma
Journal:  Jpn J Radiol       Date:  2010-08-27       Impact factor: 2.374

Review 2.  [Interventional MRI of the breast. Indications, technique, results and perspectives].

Authors:  K Hellerhoff; T Schlossbauer; P Herzog; M Reiser
Journal:  Radiologe       Date:  2008-04       Impact factor: 0.635

Review 3.  [Magnetic resonance imaging in preoperative staging for breast cancer: pros and contras].

Authors:  C K Kuhl; M Braun
Journal:  Radiologe       Date:  2008-04       Impact factor: 0.635

4.  A novel MR-guided interventional device for 3D circumferential access to breast tissue.

Authors:  Matthew Smith; Xu Zhai; Ray Harter; Gale Sisney; Mai Elezabye; Sean Fain
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  MR mammography in the pre-operative staging of breast cancer in patients with dense breast tissue: comparison with mammography and ultrasound.

Authors:  M Van Goethem; K Schelfout; L Dijckmans; J C Van Der Auwera; J Weyler; I Verslegers; I Biltjes; A De Schepper
Journal:  Eur Radiol       Date:  2003-11-13       Impact factor: 5.315

6.  Outcome of MRI-guided vacuum-assisted breast biopsy - initial experience at Institute of Oncology Ljubljana, Slovenia.

Authors:  Marta Zebic-Sinkovec; Kristijana Hertl; Maksimiljan Kadivec; Mihael Cavlek; Gasper Podobnik; Marko Snoj
Journal:  Radiol Oncol       Date:  2012-05-11       Impact factor: 2.991

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.