Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast.

Blake T Larson1, Arthur G Erdman, Nikolaos V Tsekos, Essa Yacoub, Panagiotis V Tsekos, Ioannis G Koutlas.   

Abstract

The objective of this work was to develop a robotic device to perform biopsy and therapeutic interventions in the breast with real-time magnetic resonance imaging (MRI) guidance. The device was designed to allow for (i) stabilization of the breast by compression, (ii) definition of the interventional probe trajectory by setting the height and pitch of a probe insertion apparatus, and (iii) positioning of an interventional probe by setting the depth of insertion. The apparatus is fitted with five computer-controlled degrees of freedom for delivering an interventional procedure. The entire device is constructed of MR compatible materials, i.e. nonmagnetic and non-conductive, to eliminate artifacts and distortion of the MR images. The apparatus is remotely controlled by means of ultrasonic motors and a graphical user interface, providing real-time MR-guided planning and monitoring of the operation. Joint motion measurements found probe placement in less than 50 s and sub-millimeter repeatability of the probe tip for same-direction point-to-point movements. However, backlash in the rotation joint may incur probe tip positional errors of up to 5 mm at a distance of 40 mm from the rotation axis, which may occur for women with large breasts. The imprecision caused by this backlash becomes negligible as the probe tip nears the rotation axis. Real-time MR-guidance will allow the physician to correct this error Compatibility of the device within the MR environment was successfully tested on a 4 Tesla MR human scanner

Entities:  

Mesh:

Year:  2004        PMID: 15543863     DOI: 10.1115/1.1785803

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  20 in total

1.  Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.

Authors:  Ningbo Yu; Roger Gassert; Robert Riener
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-09-02       Impact factor: 2.924

2.  Preclinical evaluation of an integrated robotic system for magnetic resonance imaging guided shoulder arthrography.

Authors:  Niravkumar Patel; Jiawen Yan; Reza Monfaredi; Karun Sharma; Kevin Cleary; Iulian Iordachita
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-15

3.  Fast and efficient radiological interventions via a graphical user interface commanded magnetic resonance compatible robotic device.

Authors:  Alpay Ozcan; Eftychios Christoforou; Daniel Brown; Nikolaos Tsekos
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

4.  Automatic brachytherapy seed placement under MRI guidance.

Authors:  Alexandru Patriciu; Doru Petrisor; Michael Muntener; Dumitru Mazilu; Michael Schär; Dan Stoianovici
Journal:  IEEE Trans Biomed Eng       Date:  2007-08       Impact factor: 4.538

5.  MRI-compatible manipulator with remote-center-of-motion control.

Authors:  Nobuhiko Hata; Junichi Tokuda; Shelley Hurwitz; Shigehiro Morikawa
Journal:  J Magn Reson Imaging       Date:  2008-05       Impact factor: 4.813

6.  A general-purpose MR-compatible robotic system: implementation and image guidance for performing minimally invasive interventions..

Authors:  Nikolaos V Tsekos; Eftychios Christoforou; Alpay Ozcan
Journal:  IEEE Eng Med Biol Mag       Date:  2008 May-Jun

7.  The Interconnection of MRI Scanner and MR-Compatible Robotic Device: Synergistic Graphical User Interface to Form a Mechatronic System.

Authors:  Alpay Ozcan; Nikolaos Tsekos
Journal:  IEEE ASME Trans Mechatron       Date:  2008-06-01       Impact factor: 5.303

8.  An Integrated Robotic System for MRI-Guided Neuroablation: Preclinical Evaluation.

Authors:  Niravkumar A Patel; Christopher J Nycz; Paulo A Carvalho; Katie Y Gandomi; Radian Gondokaryono; Gang Li; Tamas Heffter; Everette Clif Burdette; Julie G Pilitsis; Gregory S Fischer
Journal:  IEEE Trans Biomed Eng       Date:  2020-02-17       Impact factor: 4.538

9.  Design, Development, and Evaluation of a Master-Slave Surgical System for Breast Biopsy under Continuous MRI.

Authors:  Bo Yang; Steven Roys; U-Xuan Tan; Mathew Philip; Howard Richard; Rao Gullapalli; Jaydev P Desai
Journal:  Int J Rob Res       Date:  2014-04       Impact factor: 4.703

10.  Design and Control of a 1-DOF MRI Compatible Pneumatically Actuated Robot with Long Transmission Lines.

Authors:  Bo Yang; U-Xuan Tan; Alan McMillan; Rao Gullapalli; Jaydev P Desai
Journal:  IEEE ASME Trans Mechatron       Date:  2011-12-01       Impact factor: 5.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.