PURPOSE: To develop a T1rho-prepared, balanced gradient echo (b-GRE) pulse sequence for rapid three-dimensional (3D) T1rho relaxation mapping within the time constraints of a clinical exam (<10 minutes), examine the effect of acquisition on the measured T1rho relaxation time and optimize 3D T1rho pulse sequences for the knee joint and spine. MATERIALS AND METHODS: A pulse sequence consisting of inversion recovery-prepared, fat saturation, T1rho-preparation, and b-GRE image acquisition was used to obtain 3D volume coverage of the patellofemoral and tibiofemoral cartilage and lower lumbar spine. Multiple T1rho-weighted images at various contrast times (spin-lock pulse duration [TSL]) were used to construct a T1rho relaxation map in both phantoms and in the knee joint and spine in vivo. The transient signal decay during b-GRE image acquisition was corrected using a k-space filter. The T1rho-prepared b-GRE sequence was compared to a standard T1rho-prepared spin echo (SE) sequence and pulse sequence parameters were optimized numerically using the Bloch equations. RESULTS: The b-GRE transient signal decay was found to depend on the initial T1rho-preparation and the corresponding T1rho map was altered by variations in the point spread function with TSL. In a two compartment phantom, the steady state response was found to elevate T1rho from 91.4+/-6.5 to 293.8+/-31 and 66.9+/-3.5 to 661+/-207 with no change in the goodness-of-fit parameter R2. Phase encoding along the longest cartilage dimension and a transient signal decay k-space filter retained T1rho contrast. Measurement of T1rho using the T1rho-prepared b-GRE sequence matches standard T1rho-prepared SE in the medial patellar and lateral patellar cartilage compartments. T1rho-preparedb-GRE T1rho was found to have low interscan variability between four separate scans. Mean patellar cartilage T1rho was elevated compared to femoral and tibial cartilage T1rho. CONCLUSION: The T1rho-prepared b-GRE acquisition rapidly and reliably accelerates T1rho quantification of tissues offset partially by a TSL-dependent point spread function. Copyright (c) 2008 Wiley-Liss, Inc.
PURPOSE: To develop a T1rho-prepared, balanced gradient echo (b-GRE) pulse sequence for rapid three-dimensional (3D) T1rho relaxation mapping within the time constraints of a clinical exam (<10 minutes), examine the effect of acquisition on the measured T1rho relaxation time and optimize 3D T1rho pulse sequences for the knee joint and spine. MATERIALS AND METHODS: A pulse sequence consisting of inversion recovery-prepared, fat saturation, T1rho-preparation, and b-GRE image acquisition was used to obtain 3D volume coverage of the patellofemoral and tibiofemoral cartilage and lower lumbar spine. Multiple T1rho-weighted images at various contrast times (spin-lock pulse duration [TSL]) were used to construct a T1rho relaxation map in both phantoms and in the knee joint and spine in vivo. The transient signal decay during b-GRE image acquisition was corrected using a k-space filter. The T1rho-prepared b-GRE sequence was compared to a standard T1rho-prepared spin echo (SE) sequence and pulse sequence parameters were optimized numerically using the Bloch equations. RESULTS: The b-GRE transient signal decay was found to depend on the initial T1rho-preparation and the corresponding T1rho map was altered by variations in the point spread function with TSL. In a two compartment phantom, the steady state response was found to elevate T1rho from 91.4+/-6.5 to 293.8+/-31 and 66.9+/-3.5 to 661+/-207 with no change in the goodness-of-fit parameter R2. Phase encoding along the longest cartilage dimension and a transient signal decay k-space filter retained T1rho contrast. Measurement of T1rho using the T1rho-prepared b-GRE sequence matches standard T1rho-prepared SE in the medial patellar and lateral patellar cartilage compartments. T1rho-preparedb-GRE T1rho was found to have low interscan variability between four separate scans. Mean patellar cartilage T1rho was elevated compared to femoral and tibial cartilage T1rho. CONCLUSION: The T1rho-prepared b-GRE acquisition rapidly and reliably accelerates T1rho quantification of tissues offset partially by a TSL-dependent point spread function. Copyright (c) 2008 Wiley-Liss, Inc.
Authors: Xiaojuan Li; Eric T Han; C Benjamin Ma; Thomas M Link; David C Newitt; Sharmila Majumdar Journal: Magn Reson Med Date: 2005-10 Impact factor: 4.668
Authors: Justin Hulvershorn; Arijitt Borthakur; Luke Bloy; Eugene E Gualtieri; Ravinder Reddy; John S Leigh; Mark A Elliott Journal: Magn Reson Med Date: 2005-11 Impact factor: 4.668
Authors: Jesus Lozano; Xiaojuan Li; Thomas M Link; Marc Safran; Sharmila Majumdar; C Benjamin Ma Journal: J Bone Joint Surg Am Date: 2006-06 Impact factor: 5.284
Authors: Joshua D Auerbach; Wade Johannessen; Arijitt Borthakur; Andrew J Wheaton; Carol A Dolinskas; Richard A Balderston; Ravinder Reddy; Dawn M Elliott Journal: Eur Spine J Date: 2006-03-22 Impact factor: 3.134
Authors: Mohammad Haris; Anup Singh; Kejia Cai; Christos Davatzikos; John Q Trojanowski; Elias R Melhem; Christopher M Clark; Arijitt Borthakur Journal: J Neurol Date: 2010-10-07 Impact factor: 4.849
Authors: Arijitt Borthakur; Matthew Sochor; Christos Davatzikos; John Q Trojanowski; Christopher M Clark Journal: Neuroimage Date: 2008-04-01 Impact factor: 6.556
Authors: Walter R T Witschey; James J Pilla; Giovanni Ferrari; Kevin Koomalsingh; Mohammed Haris; Robin Hinmon; Gerald Zsido; Joseph H Gorman; Robert C Gorman; Ravinder Reddy Journal: Magn Reson Med Date: 2010-11 Impact factor: 4.668