Literature DB >> 16755535

T2-weighted balanced SSFP imaging (T2-TIDE) using variable flip angles.

Dominik Paul1, Michael Markl, Hans-Peter Fautz, Jürgen Hennig.   

Abstract

A new technique for acquiring T2-weighted, balanced steady-state free precession (b-SSFP) images is presented. Based on the recently proposed transition into driven equilibrium (TIDE) method, T2-TIDE uses a special flip angle scheme to achieve T2-weighted signal decay during the transient phase. In combination with half-Fourier image acquisition, T2-weighted images can be obtained using T2-TIDE. Numerical simulations were performed to analyze the signal behavior of T2-TIDE in comparison with TSE and b-SSFP. The results indicate identical signal evolution of T2-TIDE and TSE during the transient phase. T2-TIDE was used in phantom experiments, and quantitative ROI analysis shows a linear relationship between TSE and T2-TIDE SNR values. T2-TIDE was also applied to abdominal and head imaging on healthy volunteers. The resulting images were analyzed quantitatively and compared with standard T2-weighted and standard b-SSFP methods. T2-TIDE images clearly revealed T2 contrast and less blurring compared to T2-HASTE images. In combination with a magnetization preparation technique, STIR-weighted images were obtained. T2-TIDE is a robust technique for acquiring T2-weighted images while exploiting the advantages of b-SSFP imaging, such as high signal-to-noise ratio (SNR) and short TRs. Copyright (c) 2006 Wiley-Liss, Inc.

Mesh:

Year:  2006        PMID: 16755535     DOI: 10.1002/mrm.20922

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

Review 1.  Advances in magnetic resonance neuroimaging.

Authors:  Michael E Moseley; Chunlei Liu; Sandra Rodriguez; Thomas Brosnan
Journal:  Neurol Clin       Date:  2009-02       Impact factor: 3.806

2.  Transition into driven equilibrium of the balanced steady-state free precession as an ultrafast multisection T2-weighted imaging of the brain.

Authors:  Y-C K Huang; T-Y Huang; H-C Chiu; T-S Kuo; C-J Hsueh; H-W Kao; C-W Wang; H-H Hsu; C-J Juan
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-10       Impact factor: 3.825

3.  Resolution enhanced T1-insensitive steady-state imaging.

Authors:  Jamal J Derakhshan; Sherif G Nour; Jeffrey L Sunshine; Mark A Griswold; Jeffrey L Duerk
Journal:  Magn Reson Med       Date:  2011-11-30       Impact factor: 4.668

4.  MR-guided sclerotherapy of low-flow vascular malformations using T2 -weighted interrupted bSSFP (T2 W-iSSFP): comparison of pulse sequences for visualization and needle guidance.

Authors:  Di Xu; Daniel A Herzka; Wesley D Gilson; Elliot R McVeigh; Jonathan S Lewin; Clifford R Weiss
Journal:  J Magn Reson Imaging       Date:  2014-01-06       Impact factor: 4.813

5.  T1rho-prepared balanced gradient echo for rapid 3D T1rho MRI.

Authors:  Walter R T Witschey; Arijitt Borthakur; Mark A Elliott; Matthew Fenty; Matthew A Sochor; Chenyang Wang; Ravinder Reddy
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.