Literature DB >> 18722272

Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method.

He Wang1, Adam S Garden, Lifei Zhang, Xiong Wei, Anesa Ahamad, Deborah A Kuban, Ritsuko Komaki, Jennifer O'Daniel, Yongbin Zhang, Radhe Mohan, Lei Dong.   

Abstract

PURPOSE: Auto-propagation of anatomic regions of interest from the planning computed tomography (CT) scan to the daily CT is an essential step in image-guided adaptive radiotherapy. The goal of this study was to quantitatively evaluate the performance of the algorithm in typical clinical applications. METHODS AND MATERIALS: We had previously adopted an image intensity-based deformable registration algorithm to find the correspondence between two images. In the present study, the regions of interest delineated on the planning CT image were mapped onto daily CT or four-dimensional CT images using the same transformation. Postprocessing methods, such as boundary smoothing and modification, were used to enhance the robustness of the algorithm. Auto-propagated contours for 8 head-and-neck cancer patients with a total of 100 repeat CT scans, 1 prostate patient with 24 repeat CT scans, and 9 lung cancer patients with a total of 90 four-dimensional CT images were evaluated against physician-drawn contours and physician-modified deformed contours using the volume overlap index and mean absolute surface-to-surface distance.
RESULTS: The deformed contours were reasonably well matched with the daily anatomy on the repeat CT images. The volume overlap index and mean absolute surface-to-surface distance was 83% and 1.3 mm, respectively, compared with the independently drawn contours. Better agreement (>97% and <0.4 mm) was achieved if the physician was only asked to correct the deformed contours. The algorithm was also robust in the presence of random noise in the image.
CONCLUSION: The deformable algorithm might be an effective method to propagate the planning regions of interest to subsequent CT images of changed anatomy, although a final review by physicians is highly recommended.

Entities:  

Mesh:

Year:  2008        PMID: 18722272      PMCID: PMC2593788          DOI: 10.1016/j.ijrobp.2008.05.008

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  40 in total

1.  Segmentation of prostate boundaries from ultrasound images using statistical shape model.

Authors:  Dinggang Shen; Yiqiang Zhan; Christos Davatzikos
Journal:  IEEE Trans Med Imaging       Date:  2003-04       Impact factor: 10.048

Review 2.  4-dimensional computed tomography imaging and treatment planning.

Authors:  Paul Keall
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

3.  A fast dose calculation method based on table lookup for IMRT optimization.

Authors:  Qiuwen Wu; David Djajaputra; Marc Lauterbach; Yan Wu; Radhe Mohan
Journal:  Phys Med Biol       Date:  2003-06-21       Impact factor: 3.609

4.  Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system.

Authors:  Laurence Court; Isaac Rosen; Radhe Mohan; Lei Dong
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

5.  Flat-panel cone-beam computed tomography for image-guided radiation therapy.

Authors:  David A Jaffray; Jeffrey H Siewerdsen; John W Wong; Alvaro A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-08-01       Impact factor: 7.038

6.  GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration.

Authors:  G C Sharp; N Kandasamy; H Singh; M Folkert
Journal:  Phys Med Biol       Date:  2007-09-10       Impact factor: 3.609

7.  Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee.

Authors:  Gary A Ezzell; James M Galvin; Daniel Low; Jatinder R Palta; Isaac Rosen; Michael B Sharpe; Ping Xia; Ying Xiao; Lei Xing; Cedric X Yu
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

8.  The influence of interpatient and intrapatient rectum variation on external beam treatment of prostate cancer.

Authors:  D Yan; B Xu; D Lockman; K Kota; D S Brabbins; J Wong; A A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-11-15       Impact factor: 7.038

9.  Automatic registration of the prostate for computed-tomography-guided radiotherapy.

Authors:  Laurence E Court; Lei Dong
Journal:  Med Phys       Date:  2003-10       Impact factor: 4.071

10.  A model to simulate day-to-day variations in rectum shape.

Authors:  Mischa S Hoogeman; Marcel van Herk; Di Yan; Liesbeth J Boersma; Peter C M Koper; Joos V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-10-01       Impact factor: 7.038

View more
  37 in total

Review 1.  Accurate accumulation of dose for improved understanding of radiation effects in normal tissue.

Authors:  David A Jaffray; Patricia E Lindsay; Kristy K Brock; Joseph O Deasy; W A Tomé
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-01       Impact factor: 7.038

2.  Distance-preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck.

Authors:  Jihun Kim; Martha M Matuszak; Kazuhiro Saitou; James M Balter
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

3.  Automatic segmentation of whole breast using atlas approach and deformable image registration.

Authors:  Valerie K Reed; Wendy A Woodward; Lifei Zhang; Eric A Strom; George H Perkins; Welela Tereffe; Julia L Oh; T Kuan Yu; Isabelle Bedrosian; Gary J Whitman; Thomas A Buchholz; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-17       Impact factor: 7.038

Review 4.  Magnetic resonance image guidance in external beam radiation therapy planning and delivery.

Authors:  Ilamurugu Arivarasan; Chandrasekaran Anuradha; Shanmuga Subramanian; Ayyalusamy Anantharaman; Velayudham Ramasubramanian
Journal:  Jpn J Radiol       Date:  2017-06-13       Impact factor: 2.374

5.  Online updating of context-aware landmark detectors for prostate localization in daily treatment CT images.

Authors:  Xiubin Dai; Yaozong Gao; Dinggang Shen
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

6.  Registration accuracy for MR images of the prostate using a subvolume based registration protocol.

Authors:  Joakim H Jonsson; Patrik Brynolfsson; Anders Garpebring; Mikael Karlsson; Karin Söderström; Tufve Nyholm
Journal:  Radiat Oncol       Date:  2011-06-16       Impact factor: 3.481

7.  Automated Lung Segmentation and Image Quality Assessment for Clinical 3D/4D Computed Tomography.

Authors:  Jie Wei; Guang Li
Journal:  IEEE J Transl Eng Health Med       Date:  2014       Impact factor: 3.316

8.  Statistical modeling approach to quantitative analysis of interobserver variability in breast contouring.

Authors:  Jinzhong Yang; Wendy A Woodward; Valerie K Reed; Eric A Strom; George H Perkins; Welela Tereffe; Thomas A Buchholz; Lifei Zhang; Peter Balter; Laurence E Court; X Allen Li; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-07       Impact factor: 7.038

9.  Voxel-based statistical analysis of uncertainties associated with deformable image registration.

Authors:  Shunshan Li; Carri Glide-Hurst; Mei Lu; Jinkoo Kim; Ning Wen; Jeffrey N Adams; James Gordon; Indrin J Chetty; Hualiang Zhong
Journal:  Phys Med Biol       Date:  2013-09-03       Impact factor: 3.609

10.  Evolution of surface-based deformable image registration for adaptive radiotherapy of non-small cell lung cancer (NSCLC).

Authors:  Matthias Guckenberger; Kurt Baier; Anne Richter; Juergen Wilbert; Michael Flentje
Journal:  Radiat Oncol       Date:  2009-12-21       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.